Calibration of a flatbed scanner for traceable paper area measurement

被引:10
|
作者
Kangasraasio, J. [1 ]
Hemming, B. [2 ]
机构
[1] JMK Instruments Oy, FI-70600 Kuopio, Finland
[2] Ctr Metrol & Accreditat MIKES, FI-02150 Espoo, Finland
关键词
traceable area measurement; geometric calibration; radiometric calibration; flatbed scanner; uncertainty analysis;
D O I
10.1088/0957-0233/20/10/107003
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this note, we describe a method to calibrate a flatbed scanner to perform traceable paper sample area measurements. Also a detailed uncertainty analysis is presented. The achieved relative uncertainty at the 95% confidence level of the area measurement is under 0.1%. Described calibration procedures can also be used in other applications where dimensional measurements are performed with a flatbed scanner.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Traceable radiometric calibration of semiconductor detectors and their application for thermodynamic temperature measurement
    J. Hartmann
    J. Hollandt
    P. Meindl
    D. Taubert
    L. Werner
    MAPAN, 2010, 25 : 3 - 10
  • [32] Calibration of GafChromic XR-RV3 radiochromic film for skin dose measurement using standardized x-ray spectra and a commercial flatbed scanner
    McCabe, Bradley P.
    Speidel, Michael A.
    Pike, Tina L.
    Van Lysel, Michael S.
    MEDICAL PHYSICS, 2011, 38 (04) : 1919 - 1930
  • [33] Hardened concrete air void analysis with a flatbed scanner
    Peterson, KW
    Swartz, RA
    Sutter, LL
    Van Dam, TJ
    CONCRETE 2001: MATERIALS AND CONSTRUCTION, 2001, (1775): : 36 - 43
  • [34] Traceable radiometric calibration of semiconductor detectors and their application for thermodynamic temperature measurement
    Hartmann, J.
    Hollandt, J.
    Meindl, P.
    Taubert, D.
    Werner, L.
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2010, 25 (01): : 3 - 10
  • [35] Improving integrity of on-line grammage measurement with traceable basic calibration
    Kangasraasio, Juha
    ISA TRANSACTIONS, 2010, 49 (03) : 257 - 263
  • [36] Assessment of early attrition using an ordinary flatbed scanner
    van't Spijker, Arie
    Kreulen, Cees M.
    Bronkhorst, Ewald M.
    Creugers, Nico H. J.
    JOURNAL OF DENTISTRY, 2012, 40 (07) : 603 - 608
  • [37] Phase-shifting photoelasticity using a flatbed scanner
    Ng, TW
    Quek, PK
    Lim, KH
    OPTICAL ENGINEERING, 2003, 42 (08) : 2375 - 2379
  • [38] 0.5 gigapixel microscopy using a flatbed scanner: erratum
    Ou, Xiaoze
    Zheng, Guoan
    Yang, Changhuei
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (02): : 646 - 647
  • [39] Image graininess via flatbed scanner and image segmentation
    Kuo, CH
    Ng, YS
    IS&T'S NIP21: INTERNATIONAL CONFERENCE ON DIGITAL PRINTING TECHNOLOGIES, FINAL PROGRAM AND PROCEEDINGS, 2005, : 84 - 88
  • [40] A LARGE AREA TRITIUM STANDARD SOURCE FOR TRACEABLE CALIBRATION OF SURFACE CONTAMINATION MONITORS
    WHITLOCK, GD
    FUSION TECHNOLOGY, 1992, 21 (02): : 462 - 464