Calibration of a flatbed scanner for traceable paper area measurement

被引:10
|
作者
Kangasraasio, J. [1 ]
Hemming, B. [2 ]
机构
[1] JMK Instruments Oy, FI-70600 Kuopio, Finland
[2] Ctr Metrol & Accreditat MIKES, FI-02150 Espoo, Finland
关键词
traceable area measurement; geometric calibration; radiometric calibration; flatbed scanner; uncertainty analysis;
D O I
10.1088/0957-0233/20/10/107003
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this note, we describe a method to calibrate a flatbed scanner to perform traceable paper sample area measurements. Also a detailed uncertainty analysis is presented. The achieved relative uncertainty at the 95% confidence level of the area measurement is under 0.1%. Described calibration procedures can also be used in other applications where dimensional measurements are performed with a flatbed scanner.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Measurement of leaf surface area using NIH Image software and a flatbed scanner.
    Hammer, MF
    Dinsmore, SC
    Woodard, JL
    PLANT PHYSIOLOGY, 1997, 114 (03) : 1665 - 1665
  • [2] Methodology to use flatbed image scanner for formation analysis of paper
    Enomae, Toshiharu
    Kuga, Shigenori
    Kami Pa Gikyoshi/Japan Tappi Journal, 2002, 56 (04): : 97 - 104
  • [3] Stereoscopic flatbed scanner
    Sun, Changming
    Beare, Richard
    Cheong, Kevin
    Jung, Brian J.
    Kim, Maverick
    JOURNAL OF ELECTRONIC IMAGING, 2009, 18 (01)
  • [4] Traceable Calibration of pH Measurement Devices
    Spitzer, Petra
    Adel, Beatrice
    Werner, Barbara
    Jehnert, Diana
    TM-TECHNISCHES MESSEN, 2010, 77 (03) : 156 - 161
  • [5] Application of traceable sample area measurement in the calibration of online dry grammage measurement used in board production
    Kangasraasio, Juha
    MEASUREMENT, 2013, 46 (04) : 1585 - 1591
  • [6] Flow length measurement of injection molded spirals using a flatbed scanner
    Jones, Martin P.
    Callahan, Richard N.
    Bruce, Richard D.
    Journal of Industrial Technology, 2011, 27 (01):
  • [7] Traceable measurement methods for dynamic pressure calibration
    Yang Jun
    Zhang Li
    Xue Bin
    Huang Riheng
    Li Bo
    PROCEEDINGS OF 2017 13TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), VOL 1, 2017, : 545 - 551
  • [8] Measuring the illumination angle of a flatbed scanner
    Ng, TW
    Tajuddin, A
    OPTICAL ENGINEERING, 2001, 40 (03) : 415 - 417
  • [9] Low CBCT Dose Measurement for Head Phantom Using XRQA Film and a Flatbed Scanner
    Guan, H.
    Feng, W.
    Wen, N.
    Xu, Y.
    MEDICAL PHYSICS, 2011, 38 (06) : 3712 - U26
  • [10] Optimizing the setup of a flatbed color scanner for color measurement using full factorial design
    Hasanlou, Elham
    Shams-Nateri, Ali
    Izadan, Hossein
    COLOR RESEARCH AND APPLICATION, 2019, 44 (05): : 718 - 729