Split-flow injector for capillary zone electrophoresis

被引:14
|
作者
Tuma, P [1 ]
Opekar, F [1 ]
Jelínek, I [1 ]
机构
[1] Charles Univ, Dept Analyt Chem, UNESCO, Lab Environm Electrochem, CR-12840 Prague 2, Czech Republic
关键词
split-flow injector; injection methods; instrumentation; benzoic acids; nitrophenols;
D O I
10.1016/S0021-9673(00)00446-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple construction of a split-flow injector eliminating some common problems connected with the use of such devices is described. It consists of a low-pressure pump, an injection valve and a delivery tube in which the separating capillary inlet is fixed. The sample is injected without moving the separating capillary inlet and without interrupting the applied voltage. The grounded electrophoretic electrode is close to the injection valve so that all metal parts of the injector are kept at a sufficiently low potential. Minimum length and small internal diameter of delivery tube minimizes additional sample zone broadening. The effects of some experimental parameters, such as the position of the separation capillary inlet with respect to the background solution flow direction and background solution flow-rate are experimentally studied. The injector was tested primarily for the electrokinetic injection. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [21] Study of Split-Flow Wall Located at Exit
    Zhao, Guomin
    Li, Min
    Zhao, Yunfeng
    Zhng, Qingsong
    Liu, Zhongxian
    ADVANCES IN CIVIL ENGINEERING, 2017, 2017
  • [22] General theory for flow optimisation of split-flow thin fractionation
    Zhang, YH
    Emerson, DR
    Reese, JM
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1010 (01) : 87 - 94
  • [23] MODIFICATION OF ELECTROOSMOTIC FLOW WITH CETYLTRIMETHYLAMMONIUM BROMIDE IN CAPILLARY ZONE ELECTROPHORESIS
    TSUDA, T
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (11): : 622 - 624
  • [24] Application of an electroosmotic flow gradient in capillary zone electrophoresis separations
    Soontornniyomkij, B
    Chen, S
    Minnoor, ES
    Pietrzyk, DJ
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1998, 21 (19) : 2957 - 2976
  • [25] 2NL INJECTOR FOR CAPILLARY ELECTROPHORESIS
    HANAI, T
    TSURUTA, H
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 1994, 22 (02) : 151 - 155
  • [26] INTERACTION OF CAPILLARY ZONE ELECTROPHORESIS WITH A SHEATH FLOW CUVETTE DETECTOR
    CHENG, YF
    WU, SL
    CHEN, DY
    DOVICHI, NJ
    ANALYTICAL CHEMISTRY, 1990, 62 (05) : 496 - 503
  • [27] THEORETICAL-MODEL OF ELECTROOSMOTIC FLOW FOR CAPILLARY ZONE ELECTROPHORESIS
    TAVARES, MFM
    MCGUFFIN, VL
    ANALYTICAL CHEMISTRY, 1995, 67 (20) : 3687 - 3696
  • [28] ADAPTATION OF A MICRODROP INJECTOR TO SAMPLING IN CAPILLARY ELECTROPHORESIS
    SZIELE, D
    BRUGGEMANN, O
    DORING, M
    FREITAG, R
    SCHUGERL, K
    JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) : 254 - 258
  • [29] BIOSENSING OF CHOLESTEROL WITH USE OF A SPLIT-FLOW ENZYME THERMISTOR
    SATOH, I
    TERAMURA, N
    SENSORS AND ACTUATORS B-CHEMICAL, 1991, 5 (1-4) : 249 - 252
  • [30] Separation of nicotine metabolites by capillary zone electrophoresis and capillary zone electrophoresis/mass spectrometry
    Palmer, ME
    Smith, RF
    Chambers, K
    Tetler, LW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (03) : 224 - 231