A Comparison of the Deflecting-Tip Bronchial Blocker With a Wire-Guided Blocker or Left-Sided Double-Lumen Tube

被引:33
|
作者
Dumans-Nizard, Virginie [1 ]
Liu, Ngai [1 ]
Laloe, Pierre-Antoine [1 ]
Fischler, Marc [1 ]
机构
[1] Hop Foch, Dept Anesthesiol, F-92151 Suresnes, France
关键词
one-lung ventilation; double-lumen endotracheal tube; bronchial blocker; TORQUE CONTROL BLOCKER; ONE-LUNG VENTILATION; ENDOTRACHEAL-TUBE; CARDIAC-SURGERY;
D O I
10.1053/j.jvca.2009.02.002
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To compare a new bronchial blocker, the Cohen blocker, with the Arndt blocker and a left double-lumen tube (DLT). Design: A prospective, randomized, controlled trial. Setting: University hospital. Participants: Forty-eight patients undergoing lung surgery. Intervention: Intubation with 1 of the 3 devices. Comparisons among groups included (1) time for initial positioning, (2) degree of lung collapse at pleura opening, and (3) number of intraoperative fiberoptic examinations. Measurements and Main Results: Positioning of the Cohen blocker (256 [166-341] seconds; median [interquartile range]) took no longer compared with the Arndt blocker (253 [184-305] seconds), and there was a trend toward difference between the 2 blockers and the DLT (137 [102-199] seconds) (p = 0.07). The time to place the Cohen blocker was longer in cases of left bronchus occlusion compared with a right one (340 [300-450] v 170 [124-259] seconds, p = 0.02); they were similar in the Arndt group. The degree of lung collapse was different among groups (p = 0.05), but the difference between any pair did not reach statistical significance. The number of patients who required at least 1 additional FOB examination was not statistically different (50% of patients in each blocker group v 19% in the DLT group). Conclusions: There was a trend toward a difference between times to place a bronchial blocker and the DLT. The Cohen blocker is more difficult to position in the left main bronchus than in the right one. (C) 2009 Elsevier Inc. All rights reserved
引用
收藏
页码:501 / 505
页数:5
相关论文
共 50 条
  • [31] Misplacement of left-sided double-lumen tubes into the right mainstem bronchus: Decreased bronchial tube angulation is a cause?
    Kumar, Amarjeet
    Sinha, Chandni
    Kumari, Poonam
    Nupoor, Neha
    Kumar, Sanjeev
    SAUDI JOURNAL OF ANAESTHESIA, 2019, 13 (03) : 262 - +
  • [32] Is there a better tube for one lung ventilation? Comparison of the modified bronchocath double-lumen tube vs single-lumen tube with enclosed bronchial blocker
    Campos, JH
    Reasoner, DK
    Moyers, JR
    ANESTHESIOLOGY, 1996, 85 (3A) : A424 - A424
  • [33] PROPER LATERALIZATION OF LEFT-SIDED DOUBLE-LUMEN TUBES
    NEUSTEIN, SM
    EISENKRAFT, JB
    ANESTHESIOLOGY, 1989, 71 (06) : 996 - 997
  • [34] MALPOSITION OF LEFT-SIDED DOUBLE-LUMEN ENDOBRONCHIAL TUBES
    HIRSCH, NP
    SMITH, GB
    ANESTHESIOLOGY, 1985, 63 (05) : 563 - 563
  • [35] MALPOSITION OF LEFT-SIDED DOUBLE-LUMEN ENDOBRONCHIAL TUBES
    BRODSKY, JB
    SHULMAN, MS
    MARK, JBD
    ANESTHESIOLOGY, 1985, 62 (05) : 667 - 669
  • [36] Bronchial blocker and double-lumen endotracheal tube combination to facilitate lung isolation during esophagectomy
    Liang, Hong
    Thomas, Mathew
    Renew, J. Ross
    ANNALS OF CARDIAC ANAESTHESIA, 2022, 25 (02) : 214 - 216
  • [37] Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy
    Bauer, C
    Winter, C
    Hentz, JG
    Ducrocq, X
    Steib, A
    Dupeyron, JP
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (02) : 250 - 254
  • [38] Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial
    Seo, Jeong-Hwa
    Yoon, Susie
    Min, Se-Hee
    Row, Hyung Sang
    Bahk, Jae-Hyon
    PLOS ONE, 2019, 14 (01):
  • [39] Placement of left-sided double-lumen endobronchial tubes: comparison of clinical and fibreoptic-guided placement
    Cheong, KF
    Koh, KF
    BRITISH JOURNAL OF ANAESTHESIA, 1999, 82 (06) : 920 - 921
  • [40] Difficulty in placement of a left-sided double-lumen tube due to aberrant tracheobronchial anatomy
    Yoshimura, Tatsuya
    Ueda, Ken-ichi
    Kakinuma, Akihito
    Nakata, Yoshinori
    JOURNAL OF CLINICAL ANESTHESIA, 2013, 25 (05) : 413 - 416