A new high sensitivity thermoluminescent phosphor with low residual signal and good stability to heat treatment:: LiF:Mg,Cu,Na,Si

被引:15
|
作者
Tang, K [1 ]
Zhu, H [1 ]
Shen, W [1 ]
Liu, B [1 ]
机构
[1] Solid Dosimetr Detector & Method Lab, Beijing 102205, Peoples R China
关键词
D O I
10.1093/oxfordjournals.rpd.a005855
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The preliminary investigations are reported on the characteristics of a new. high-sensitivity thermoluminescence phosphor material (LiF:Mg,Cu,Na,Si) prepared in this laboratory. The main dosimetric peak of this phosphor occurs at 197degreesC at a heating rate of 1degreesC.s(-1). The glow curve shape shows minimal differences and sensitivity remains stable when annealed in the range from 250 to 280 C for 10 min. Its TL sensitivity to gamma radiation is about 30 times higher than that of TLD-100 with a residual signal 0.2% following a 260degreesC readout at a heating rate of 15degreesC.s(-1). This negligible residual signal renders LiF:Mg,Cu,Na,Si usable in unannealed form. Its TL response at both 260degreesC and 280degreesC are reproducible within a coefficient of variation of 2% over ten re-use cycles without systematic decrease. It retains the main advantages of LiF:Mg,Cu,P phosphor, and has a lower residual signal and a better stability to heat treatment.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 48 条
  • [1] A new high sensitivity thermoluminescent phosphor with low residual signal and good stability to heat treatment:: LiF:Mg,Cu,Na,Si
    Tang, K
    Zhu, H
    Shen, W
    Liu, B
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : 239 - 242
  • [3] On the roles of the dopants in LiF: Mg,Cu,Na,Si thermoluminescent material
    Lee, JI
    Kim, JL
    Chang, SY
    Chung, KS
    Choe, HS
    RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 340 - 344
  • [4] A HIGH-SENSITIVITY LIF THERMOLUMINESCENT DOSIMETER - LIF(MG, CU, P)
    WU, DK
    SUN, FY
    DAI, HC
    HEALTH PHYSICS, 1984, 46 (05): : 1063 - 1067
  • [5] Preparation and thermoluminescent dosimetry features of high sensitivity LiF:Mg,Ce phosphor
    Shoushtari, M. K.
    Zahedifar, M.
    Sadeghi, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 887 : 128 - 132
  • [6] Dependence of thermoluminescence in LiF:Mg,Cu,Na,Si phosphor on Na dopant concentration and thermal treatment
    Tang, KY
    RADIATION MEASUREMENTS, 2003, 37 (02) : 133 - 140
  • [7] Studies on the thermoluminescence spectra and thermal stability of LiF:Mg,Cu, LiF:Mg,Cu,Na and LiF:Mg,Cu,Si
    Yang, B
    Lu, Q
    Wang, S
    Townsend, PD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (03): : 171 - 178
  • [8] Development of LiF:Mg,Cu,Si TL material (new KLT-300) with a low-residual signal and high-thermal stability
    Lee, J. I.
    Kim, J. L.
    Rahman, M. S.
    Chang, S. Y.
    Chung, K. S.
    Choe, H. S.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 229 - 232
  • [9] Newly developed highly sensitive LiF:Mg,Cu,Si TL discs with good stability to heat treatment
    Tang, K.
    Cui, H.
    Zhu, H.
    Liu, Z.
    Fan, H.
    RADIATION MEASUREMENTS, 2012, 47 (02) : 185 - 189
  • [10] A HIGH-SENSITIVITY LIF-MG,CU,P THERMOLUMINESCENT DOSIMETER
    KOLOTILIN, VV
    HOKHREKOV, VI
    TARASOVA, LM
    ZAKHRIAPIN, SB
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (01): : 169 - 171