Functional results and photic phenomena with new extended-depth-of-focus intraocular Lens

被引:35
|
作者
Giers, Bert C. [1 ]
Khoramnia, Ramin [1 ]
Varadi, Dorottya [1 ]
Wallek, Hannah [1 ]
Son, Hyeck-Soo [1 ]
Attia, Mary S. [1 ]
Auffarth, Gerd U. [1 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, David J Apple Ctr Vis Res, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
Cataract; Intraocular Lens; Multifocal; Visual outcomes; BILATERAL READING PERFORMANCE; VISUAL OUTCOMES; CLINICAL-OUTCOMES; IMPLANTATION; VISION; RANGE; SURGERY; DESIGN; MODELS; ACUITY;
D O I
10.1186/s12886-019-1201-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Evaluation of clinical and functional results of a new extended depth of focus intraocular lens (EDOF-IOL). Methods Fourteen cataract patients (28 bilateral implantations) were assessed for uncorrected (UDVA) and corrected (CDVA) distance visual acuities; uncorrected (UNVA), distance-corrected (DCNVA) and best corrected (CNVA) near visual acuities; and uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuities - as well as binocular defocus curves. Photopic and mesopic contrast sensitivity was recorded. Reading acuity was evaluated using an electronic reading desk at fixed distances and at the patient's preferred near and intermediate distances. Visual symptoms were assessed with a halo and glare simulator plus a patient questionnaire which also recorded quality of life. Results Median postoperative monocular UDVA was 0.13logMAR (range - 0.08 to 0.42logMAR), median CDVA was - 0.01logMAR (range - 0.20 to 0.22logMAR), median UIVA at 80 cm was - 0.05logMAR (range - 0.18 to 0.58logMAR) and median UNVA at 40 cm was 0.14logMAR (range - 0.10 to 0.64logMAR). Binocular uncorrected reading acuity was 0.10logMAR at 40 cm and 0.11logMAR at 80 cm. Patients preferred a median intermediate reading distance of 62.8 cm over the predetermined 80 cm, which allowed them to read smaller letter size but did not improve reading acuity. Patients reported a high rate of spectacle independence and satisfaction in everyday life and little to no dysphotopsia. Conclusion The Mini WELL Ready IOL provided good postoperative functional results at far and intermediate distances and improved the visual and reading acuity at reading distance. The lens caused little to no dysphotopsia.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] New set of complementary extended-depth-of-focus IOL: comparison with the state-of-the-art
    Castignoles, Fannie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [42] Comparative Visual Outcome Analysis of a Diffractive Multifocal Intraocular Lens and a New Diffractive Multifocal Lens with Extended Depth of Focus
    Moshirfar, Majid
    Stapley, Seth R.
    Corbin, Wyatt M.
    Bundogji, Nour
    Conley, Matthew
    Darquea, Ines M.
    Ronquillo, Yasmyne C.
    Hoopes, Phillip C.
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (24)
  • [43] Analysis and comparison of monofocal, extended depth of focus and trifocal intraocular lens profiles
    Juan J. Miret
    Vicente J. Camps
    Celia García
    Maria T. Caballero
    Juan M. Gonzalez-Leal
    Scientific Reports, 12
  • [44] Clinical Evaluation of an Extended Depth of Focus Intraocular Lens With the Salzburg Reading Desk
    Attia, Mary S. A.
    Auffarth, Gerd U.
    Kretz, Florian T. A.
    Tandogan, Tamer
    Rabsilber, Tanja M.
    Holzer, Mike P.
    Khoramnia, Ramin
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (10) : 664 - +
  • [45] Outcomes and predictive factors in multifocal and extended depth of focus intraocular lens implantation
    de la Paz, Matthew
    Tsai, Linda M.
    CURRENT OPINION IN OPHTHALMOLOGY, 2024, 35 (01) : 28 - 33
  • [46] Quality of view through extended depth of focus intraocular lens in a model eye
    Inoue, Makoto
    Aicher, Nina Teresa
    Itoh, Yuji
    Bissen-Miyajima, Hiroko
    Hirakata, Akito
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2021, 65 (04) : 569 - 580
  • [47] Quality of view through extended depth of focus intraocular lens in a model eye
    Makoto Inoue
    Nina Teresa Aicher
    Yuji Itoh
    Hiroko Bissen-Miyajima
    Akito Hirakata
    Japanese Journal of Ophthalmology, 2021, 65 : 569 - 580
  • [48] Design and Optical Analysis of a Refractive Aspheric Intraocular Lens with Extended Depth of Focus
    Li, Kunqi
    Chen, Xiaoqin
    Bian, Yayan
    Xing, Yuwei
    Li, Xiaolan
    Liu, Dongyu
    Liu, Yongji
    Seeger, Thomas
    OPTICS, 2023, 4 (01): : 146 - 155
  • [49] Analysis and comparison of monofocal, extended depth of focus and trifocal intraocular lens profiles
    Miret, Juan J.
    Camps, Vicente J.
    Garcia, Celia
    Caballero, Maria T.
    Gonzalez-Leal, Juan M.
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [50] Clinical outcomes of an extended depth-of-focus intraocular lens in patients with glaucoma
    Reem Amir Kamal Dessouky
    Amr Aref
    André Mermoud
    International Ophthalmology, 44 (1)