Functional results and photic phenomena with new extended-depth-of-focus intraocular Lens

被引:35
|
作者
Giers, Bert C. [1 ]
Khoramnia, Ramin [1 ]
Varadi, Dorottya [1 ]
Wallek, Hannah [1 ]
Son, Hyeck-Soo [1 ]
Attia, Mary S. [1 ]
Auffarth, Gerd U. [1 ]
机构
[1] Heidelberg Univ, Dept Ophthalmol, David J Apple Ctr Vis Res, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
Cataract; Intraocular Lens; Multifocal; Visual outcomes; BILATERAL READING PERFORMANCE; VISUAL OUTCOMES; CLINICAL-OUTCOMES; IMPLANTATION; VISION; RANGE; SURGERY; DESIGN; MODELS; ACUITY;
D O I
10.1186/s12886-019-1201-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Evaluation of clinical and functional results of a new extended depth of focus intraocular lens (EDOF-IOL). Methods Fourteen cataract patients (28 bilateral implantations) were assessed for uncorrected (UDVA) and corrected (CDVA) distance visual acuities; uncorrected (UNVA), distance-corrected (DCNVA) and best corrected (CNVA) near visual acuities; and uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuities - as well as binocular defocus curves. Photopic and mesopic contrast sensitivity was recorded. Reading acuity was evaluated using an electronic reading desk at fixed distances and at the patient's preferred near and intermediate distances. Visual symptoms were assessed with a halo and glare simulator plus a patient questionnaire which also recorded quality of life. Results Median postoperative monocular UDVA was 0.13logMAR (range - 0.08 to 0.42logMAR), median CDVA was - 0.01logMAR (range - 0.20 to 0.22logMAR), median UIVA at 80 cm was - 0.05logMAR (range - 0.18 to 0.58logMAR) and median UNVA at 40 cm was 0.14logMAR (range - 0.10 to 0.64logMAR). Binocular uncorrected reading acuity was 0.10logMAR at 40 cm and 0.11logMAR at 80 cm. Patients preferred a median intermediate reading distance of 62.8 cm over the predetermined 80 cm, which allowed them to read smaller letter size but did not improve reading acuity. Patients reported a high rate of spectacle independence and satisfaction in everyday life and little to no dysphotopsia. Conclusion The Mini WELL Ready IOL provided good postoperative functional results at far and intermediate distances and improved the visual and reading acuity at reading distance. The lens caused little to no dysphotopsia.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comparison of visual performance between bifocal and extended-depth-of-focus intraocular lenses
    Tabuchi, Hitoshi
    Tanabe, Hirotaka
    Shirakami, Tomoki
    Takase, Kosuke
    Shojo, Tomohiro
    Yamauchi, Tomofusa
    PLOS ONE, 2023, 18 (07):
  • [22] Extended depth of focus intraocular lens: chromatic performance
    Millan, Maria S.
    Vega, Fidel
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (09): : 4294 - 4309
  • [23] Trade-Off Asymmetric Profile for Extended-Depth-of-Focus Ocular Lens
    Romero, Lenny A.
    Marrugo, Andres G.
    Millan, Maria S.
    PHOTONICS, 2022, 9 (02)
  • [24] Extended depth of focus intraocular lens versus a new monofocal intraocular lens: A prospective comparative and interventional study
    Sihmar, Yogika
    Singh, Basant K.
    Singh, Vinod K.
    Kumar, Santosh
    Chaudhary, Aparajita
    Saini, Sanchita
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2023, 37 (04) : 331 - 336
  • [25] Visual outcomes of binocular implantation of a new extended depth of focus intraocular lens
    Sinha, Rajesh
    Sahay, Pranita
    Saxena, Rohit
    Kalra, Nidhi
    Gupta, Vinay
    Titiyal, Jeewan S.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (10) : 2111 - 2116
  • [26] Correction: Tolerance to refractive error with a new extended depth of focus intraocular lens
    Daniel A. Black
    Chandra Bala
    Aixa Alarcon
    Srividhya Vilupuru
    Eye, 2025, 39 (1) : 203 - 203
  • [27] The effect of trifocal and extended-depth-of-focus intraocular lenses on optical coherence tomography parameters
    Sezenoz, Almila Sarigul
    Gungor, Sirel Gur
    Dogan, Irem Kirci
    Colak, Meric Yavuz
    Gokgoz, Gulsah
    Altinors, Dilek Dursun
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (SUPPL 3) : S423 - S428
  • [28] Visualoutcomesandsafety of an extended depth-of-focus intraocular lens: results of a pivotal clinical trial
    Chang, Daniel H.
    Janakiraman, Devi Priya
    Smith, Pamela J.
    Buteyn, Anne
    Domingo, Joy
    Jones, Jason J.
    Christie, William C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (03): : 288 - 297
  • [29] Optical Performance of a Segmented Extended-Depth-of-Focus Intraocular Lens under the Influence of Different Values of Spherical Aberration Generated by Refractive Surgery
    Salva, Luis
    Garcia, Scott
    Garcia-Delpech, Salvador
    Martinez-Espert, Anabel
    Ferrando, Vicente
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (14)
  • [30] Optical and clinical simulated performance of a new refractive extended depth of focus intraocular lens
    Alarcon, Aixa
    Carrasco, Antonio del Aguila
    Gounou, Franck
    Weeber, Henk
    Canovas, Carmen
    Piers, Patricia
    EYE, 2024, 38 (SUPPL 1) : 4 - 8