The effect of cycloplegia on biometric measurements using swept-source optical coherence tomography-based biometry

被引:15
|
作者
Ozcaliskan, Sehnaz [1 ]
Yenerel, Nursal Melda [2 ]
机构
[1] Univ Hlth Sci, Beyoglu Eye Training & Res Hosp, Istanbul, Turkey
[2] Univ Hlth Sci, Haydarpasa Numune Training & Res Hosp, Istanbul, Turkey
关键词
biometry; cycloplegia; swept-source OCT; REPEATABILITY; REPRODUCIBILITY; AGREEMENT; LENSTAR;
D O I
10.1111/cxo.12888
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To evaluate the effect of pupil dilation obtained with cyclopentolate on biometric measurements using swept-source optical coherence tomography biometry. Methods This study involved 63 eyes of 63 healthy volunteers. After ophthalmic examination, biometry measurements of the participants were obtained with IOL Master 700 (Carl Zeiss Meditec AG, Jena, Germany). After pre-dilation measurements were taken, subjects were given one drop of cyclopentolate hydrochloride ophthalmic solution three times at 10-minute intervals. When cycloplegia had been achieved, a dilated fundus examination was conducted and post-dilation measurements were taken with IOL Master 700. The biometric parameters were recorded and SPSS Software 22.0 was used for statistical analysis. Results There was a significant increase in anterior chamber depth, anterior aqueous depth and central corneal thickness values after pupil dilation (p < 0.05). A significant decrease was observed in lens thickness values after cycloplegia (p < 0.05). There were no statistically significant differences between pre-dilation and post-dilation axial length, keratometry (K1, K2) and white-to-white values (p > 0.05). Conclusion This study demonstrated there is no significant difference in axial length and keratometry measurements using swept-source optical coherence tomography biometry before and after cycloplegia.
引用
收藏
页码:501 / 505
页数:5
相关论文
共 50 条
  • [31] Ocular biometry with swept-source optical coherence tomography-based optical biometer in Japanese patients with EYS-related retinitis pigmentosa: a retrospective study
    Sakai, Daiki
    Yokota, Satoshi
    Maeda, Akiko
    Hirami, Yasuhiko
    Nakamura, Makoto
    Kurimoto, Yasuo
    [J]. BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [32] Factors influencing choroidal thickness measurements using swept-source optical coherence tomography
    Caramoy, Albert
    Kirchhof, Bernd
    Cursiefen, Claus
    Heindl, Ludwig M.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [33] Advances in swept-source optical coherence tomography and optical coherence tomography angiography
    Zheng, Fang
    Deng, Xiaofeng
    Zhang, Qi
    He, Jingliang
    Ye, Panpan
    Liu, Shan
    Li, Peng
    Zhou, Jian
    Fang, Xiaoyun
    [J]. ADVANCES IN OPHTHALMOLOGY PRACTICE AND RESEARCH, 2023, 3 (02): : 67 - 79
  • [34] Anterior Segment Biometry During Accommodation and Effects of Cycloplegics by Swept-Source Optical Coherence Tomography
    Mitsukawa, Tadahiro
    Suzuki, Yumi
    Momota, Yosuke
    Suzuki, Shun
    Yamada, Masakazu
    [J]. CLINICAL OPHTHALMOLOGY, 2020, 14 : 1237 - 1243
  • [35] Success Rate of Swept-Source Optical Coherence Tomography Biometry of Eyes of Elementary School Students
    Tomita, Masatoshi
    Yamashita, Takehiro
    Terasaki, Hiroto
    Yoshihara, Naoya
    Kakiuchi, Naoko
    Sakamoto, Taiji
    [J]. CLINICAL OPHTHALMOLOGY, 2022, 16 : 3607 - 3612
  • [36] Impact and Correction of an Anterior Phakic Intraocular Lens on Swept-Source Optical Coherence Tomography Biometry
    Ribeiro, Bruno Barbosa
    Monteiro, Silvia
    Marques, Joao Heitor
    Abreu, Ana Carolina
    Pinto, Maria do Ceu
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (08) : e562 - e568
  • [37] Efficacy of Biometry Using Swept-source Optical Coherence Tomography for Posterior Chamber Phakic Intraocular Lens Implantation
    Jo, Min Soo
    Moon, Ja Yoon
    Chung, Sung Kun
    Kim, Eung Kweon
    Park, Kyu Hong
    Choi, Jin Seok
    [J]. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (05): : 374 - 381
  • [38] Analysis of Choroidal Vascularity Index in Keratoconus Patients Using Swept-Source Optical Coherence Tomography-Based Binarization Techniques
    Gutierrez-Bonet, Rosa
    Ruiz-Medrano, Jorge
    Biarnes, Marc
    Rasheed, Mohammed Abdul
    Vupparaboina, Kiran Kumar
    Chhablani, Jay
    Ruiz-Moreno, Jose M.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [39] Repeatability and agreement of Scheimpflug-based and swept-source optical biometry measurements
    Sel, Saadettin
    Stange, Jana
    Kaiser, Delia
    Kiraly, Laszlo
    [J]. CONTACT LENS & ANTERIOR EYE, 2017, 40 (05): : 318 - 322
  • [40] Novel perspectives on swept-source optical coherence tomography
    Lavinsky F.
    Lavinsky D.
    [J]. International Journal of Retina and Vitreous, 2 (1)