Development of a diagnostic feedback device to assess neonatal cardiopulmonary resuscitation chest compression performance

被引:0
|
作者
Lloyd, Debbie [1 ]
van den Heever, Dawie [1 ]
Dellimore, Kiran [1 ]
Smith, Johan [2 ,3 ]
机构
[1] Univ Stellenbosch, Dept Mech & Mechatron Engn, Biomed Engn Res Grp, Stellenbosch, South Africa
[2] Tygerberg Hosp, Dept Paediat & Child Hlth, Tygerberg, South Africa
[3] Univ Stellenbosch, Stellenbosch, South Africa
关键词
DELIVERY-ROOM; CPR;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Neonatal cardiopulmonary resuscitation (NCPR) is an important intervention to save the lives of newborns who suffer from cardiac and respiratory arrest. Despite its importance there is a dearth of NCPR research and no commercially available feedback device suitable for use during NCPR. The aim of this study is to develop a diagnostic feedback device in the form of a patch placed on the infant's chest. The diagnostic feedback patch measures both the compression depth and force during NCPR, while giving audio-visual feedback according to current NCPR guidelines. The patch was systematically evaluated by conducting a series of hardware validation tests to assess the depth, force and feedback performance. The average errors in the depth and force were found to be 10.8% and 12.4%, respectively, with maximal errors below 20.7% and 24.1%. These results along with positive outcome of the feedback test suggest that the device is reliable on a hardware level and is suitable for further evaluation in a clinical setting.
引用
收藏
页码:5805 / 5808
页数:4
相关论文
共 50 条
  • [41] Identifying the optimum chest compression point during cardiopulmonary resuscitation
    Olivari, Davide
    De Giorgio, Daria
    Fumagalli, Francesca
    Ristagno, Giuseppe
    HEART & LUNG, 2020, 49 (02): : 207 - 208
  • [42] Chest Compression Only Cardiopulmonary Resuscitation for Primary Cardiac Arrest
    Ewy, Gordon A.
    CIRCULATION, 2016, 134 (10) : 695 - 697
  • [43] Out-of-hospital cardiopulmonary resuscitation: is chest compression enough?
    Gordon A Ewy
    Nature Clinical Practice Cardiovascular Medicine, 2008, 5 : 360 - 361
  • [44] Out-of-hospital cardiopulmonary resuscitation: is chest compression enough?
    Ewy, Gordon A.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (07): : 360 - 361
  • [45] Continuous-chest-compression cardiopulmonary resuscitation for cardiac arrest
    Ewy, Gordon A.
    CIRCULATION, 2007, 116 (25) : 2894 - 2896
  • [46] What is the best chest compression technique for infant cardiopulmonary resuscitation?
    Oh, Je Hyeok
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2017, 35 (05): : 794 - 795
  • [47] Mechanical chest compression with a medical parallel manipulator for cardiopulmonary resuscitation
    Yedukondalu, G.
    Srinath, A.
    Kumar, J. Suresh
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2015, 11 (04): : 448 - 457
  • [48] Accuracy of a feedback device for cardiopulmonary resuscitation on a dental chair
    Segal, Nicolas
    Laurent, Florian
    Maman, Louis
    Plaisance, Patrick
    Augustin, Pascal
    EMERGENCY MEDICINE JOURNAL, 2012, 29 (11) : 890 - 893
  • [49] The use of a backboard during cardiopulmonary resuscitation and chest compression quality
    Houthoofdt, Ruben
    Cuvelier, Zara
    Serraes, Brecht
    Haentjens, Carl
    Mpotos, Nicolas
    Blot, Stijn
    AUSTRALIAN CRITICAL CARE, 2023, 36 (02) : 172 - 173
  • [50] Comparison of methods for the determination of cardiopulmonary resuscitation chest compression fraction
    Iyanaga, Masayuki
    Gray, Randal
    Stephens, Shannon W.
    Akinsanya, Olajide
    Rodgers, Joel
    Smyrski, Kathleen
    Wang, Henry E.
    RESUSCITATION, 2012, 83 (05) : 568 - 571