Monte Carlo calculation of point-spread functions of Compton scatter cameras

被引:12
|
作者
Wilderman, SJ [1 ]
Rogers, WL [1 ]
Knoll, GF [1 ]
Engdahl, JC [1 ]
机构
[1] APPL NUCL IMAGING INC,ELLICOTT CITY,MD 21042
关键词
Compton scatter camera; Monte Carlo; resolution;
D O I
10.1109/23.568817
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A technique has been devised for independently determining the energy and spatial resolution components of the point-spread functions of electronically collimated (Compton scatter) imaging devices using a Monte Carlo method, Monte Carlo runs are performed for the device being examined, and detailed records of exact energy loss and spatial coordinates of each interaction for each particle in the simulation are made, Taking resolution parameters from the known performance of the detectors, measured data is simulated by sampling from Gaussian distributions (fur both energy and position) about the exact interaction energy and position in both detectors, for each Monte Carlo history, Bg back-projecting cones on an event-by-event basis and calculating the closest approach of the cone to the known source point using the simulated measurement data for one of the energy and position variables and the exact interaction data for the rest of the variables, the effect of the variable in question on the point spread can be isolated, In this paper we present the calculations of the contribution to the point-spread function of the energy and spatial resolution in each detector for various source positions for a representative Compton camera configuration.
引用
收藏
页码:250 / 254
页数:5
相关论文
共 50 条
  • [31] Fast Monte Carlo calculation of scatter corrections for CBCT images
    Mainegra-Hing, Ernesto
    Kawrakow, Iwan
    INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102
  • [32] A comparison of Monte Carlo and analytic first scatter dose spread arrays
    McGary, JE
    Boyer, AL
    Mackie, TR
    MEDICAL PHYSICS, 1999, 26 (05) : 751 - 759
  • [33] STRONG GRAVITATIONAL LENS MODELING WITH SPATIALLY VARIANT POINT-SPREAD FUNCTIONS
    Rogers, Adam
    Fiege, Jason D.
    ASTROPHYSICAL JOURNAL, 2011, 743 (01):
  • [34] MIRRORS WITH POINT-SPREAD FUNCTIONS THAT EXHIBIT WAVELET-RELATED CHARACTERISTICS
    SALOMA, C
    OPTICS LETTERS, 1995, 20 (19) : 1943 - 1945
  • [35] Producing superresolved point-spread functions using a phase modulation technique
    Soskind, M.
    Soskind, R.
    Soskind, Y. G.
    NOVEL OPTICAL SYSTEMS DESIGN AND OPTIMIZATION XIII, 2010, 7787
  • [36] AN IMPROVEMENT OF COMPTON SCATTER IMAGING WITH WIDE APERTURE DETECTORS - A MONTE-CARLO STUDY
    LEE, H
    KENNEY, ES
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) : 812 - 827
  • [37] Microwave Holography Using Point-Spread Functions Measured With Calibration Objects
    Amineh, Reza K.
    McCombe, Justin J.
    Khalatpour, Ali
    Nikolova, Natalia K.
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (02) : 403 - 417
  • [38] MONTE-CARLO CALCULATION OF MULTIPLE-SCATTERING IN A COMPTON POLARIMETER
    LICHTENBERG, W
    PRZYBYLSKI, A
    NUCLEAR INSTRUMENTS & METHODS, 1972, 98 (01): : 99 - +
  • [39] Calculation of Photon Path Changes due to Scatter in Monte Carlo Simulations
    Phillips, Justin P.
    Kyriacou, Panayiotis A.
    Jones, Deric P.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4959 - 4962
  • [40] Fast Monte Carlo calculation of linear accelerator head scatter factors
    MacPherson, M
    Badeen, A
    Wilkins, D
    Gerig, L
    MEDICAL PHYSICS, 2002, 29 (06) : 1203 - 1203