High-Pitch Electrocardiogram-Triggered Computed Tomography of the Chest Initial Results

被引:67
|
作者
Lell, Michael [1 ]
Hinkmann, Fabian [1 ]
Anders, Katharina [1 ]
Deak, Paul [2 ]
Kalender, Willi A. [2 ]
Uder, Michael [1 ]
Achenbach, Stephan [3 ]
机构
[1] Univ Erlangen Nurnberg, Dept Radiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
关键词
computed tomography; pulmonary embolism; aortic dissection; coronary CT angiography; dual source CT; radiation exposure; CORONARY CT ANGIOGRAPHY; TRIPLE RULE-OUT; DUAL-SOURCE CT; IMAGE QUALITY; NONCARDIAC FINDINGS; RADIATION-EXPOSURE; MULTISLICE CT; HEART-RATES; RECONSTRUCTION; PREVALENCE;
D O I
10.1097/RLI.0b013e3181b9df7e
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Chest pain is one of the most frequent symptoms in the emergency department. A variety of different diseases, some of them acutely life threatening, can be the underlying cause. Electrocardiogram (ECG)gated computed tomography angiography of the thorax has been proposed as a cost and time effective imaging technique for these patients. We describe a new high-pitch scan mode, which has been developed specifically for low-dose ECG-triggered computed tomography angiography using dual source computed tomography (CT). Material and Methods: Twenty-four patients were examined with this technique on a second generation dual source CT system. The scan mode uses a pitch of 3.2 to acquire a spiral CT data set of the complete thorax in less than I second with a temporal resolution of 75 ms (scan parameters: 128 X 0.6 mm collimation, 0.28 seconds gantry rotation time, 370 mAs at 100 kV [15 patients] and 320 mAs at 120 kV [9 patients], reconstructed slice thickness 0.6 mm, increment 0.4 mm). Data acquisition was prospectively triggered at 50% to 60% of the RR interval to cover the range over the heart in diastole. A triple phase contrast injection protocol (total volume: 80 mL) was used to optimize enhancement of the pulmonary and systemic arterial vessels. Image quality was evaluated using a 4-point scale (1 = absence of motion artifacts; 2 = slight motion artifacts, fully evaluable; 3 = motion artifacts, but evaluable; 4 = unevaluable) on a per-segment basis. Results: The patients had an average heart rate of 68 +/- 15 bpm (range: 43-111 bpm) during data acquisition. Motion artifact free visualization of the aorta and pulmonary vessels was possible in each case, of 344 coronary artery segments, 242 (70%) had an image quality score of 1, 60 segments (17%) a score of 2, 28 segments (8%) a score of 3, and 14 segments (4%) were rated as "unevaluable." In 17 patients (10 patients with a heart rate <= 60 bpm) all segments were evaluable. The average dose length product was 113 +/- 11 mGy x cm per scan (mean effective dose 1.6 +/- 0.2 mSv) at 100 kV and 229 +/- 31 mGy x cm per scan (mean effective dose 3.2 +/- 0.4 mSv) at 120 kV. Conclusion: Our initial results indicate that this high-pitch scan mode allows motion artifact free and accurate visualization of the thoracic vessels, and diagnostic image quality of the coronary arteries in patients with low and stable heart rates at a very low radiation exposure.
引用
收藏
页码:728 / 733
页数:6
相关论文
共 50 条
  • [31] Computed tomography pulmonary angiography using high-pitch dual-source scanner technology
    Al Hassan, Donya A.
    Waheed, Khawaja B.
    El Sirafy, Mohamed N.
    Khattab, Mohamad A.
    Al-Hammadi, Hassan I.
    Ibrahim, Motassem F.
    Ibrahim, Motassem F.
    Arulanantham, Zechariah J.
    SAUDI MEDICAL JOURNAL, 2019, 40 (03) : 230 - 237
  • [32] Quantitative Analysis of Motion Artifacts in High-pitch Dual-source Computed Tomography of the Thorax
    Schulz, Boris
    Jacobi, Volkmar
    Beeres, Martin
    Bodelle, Boris
    Gruber, Tatjana
    Lee, Clara
    Bauer, Ralf
    Kerl, Matthias
    Vogl, Thomas
    Zangos, Stefan
    JOURNAL OF THORACIC IMAGING, 2012, 27 (06) : 382 - 386
  • [33] Evaluation of High-Pitch Ungated Pediatric Cardiovascular Computed Tomography for the Assessment of Cardiac Structures in Neonates
    Sriharan, Mona
    Lazoura, Olga
    Pavitt, Christopher W.
    Castellano, Isabel
    Owens, Catherine M.
    Rubens, Michael B.
    Padley, Simon P. G.
    Nicol, Edward D.
    JOURNAL OF THORACIC IMAGING, 2016, 31 (03) : 177 - 182
  • [34] High-pitch, Dual-source Chest Computed Tomography Angiography Without Electrocardiographic Synchronization Evaluation of Cardiac Motion Artifacts on Pulmonary Circulation
    Tacelli, Nunzia
    Darchis, Christine
    Pontana, Francois
    Faivre, Jean-Baptiste
    Deken, Valerie
    Duhamel, Alain
    Murphy, Colm
    Remy, Jacques
    Remy-Jardin, Martine
    JOURNAL OF THORACIC IMAGING, 2013, 28 (06) : 376 - 382
  • [35] Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch
    Matthias S. May
    Paul Deak
    Axel Kuettner
    Michael M. Lell
    Wolfgang Wuest
    Michael Scharf
    Andrea K. Keller
    Lothar Häberle
    Stephan Achenbach
    Martin Seltmann
    Michael Uder
    Willi A. Kalender
    European Radiology, 2012, 22 : 569 - 578
  • [36] Motion Artifact Reduction From High-Pitch Dual-Source Computed Tomography Pulmonary Angiography
    Bunch, Paul M.
    Fulwadhva, Urvi P.
    Wortman, Jeremy R.
    Primak, Andrew N.
    Madan, Rachna
    Steigner, Michael L.
    Sodickson, Aaron D.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (04) : 623 - 629
  • [37] COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY WITH A CONSISTENT DOSE BELOW 2 MSV USING DOUBLE PROSPECTIVELY ECG-TRIGGERED HIGH-PITCH SPIRAL ACQUISITION IN PATIENTS WITH ATRIAL FIBRILLATION: INITIAL EXPERIENCE
    Wang Qi
    Chen Yundai
    HEART, 2013, 99 : E268 - E268
  • [38] Computed tomography coronary angiography with a consistent dose below 2 mSv using double prospectively ECG-triggered high-pitch spiral acquisition in patients with atrial fibrillation: initial experience
    Wang, Qi
    Qin, Jing
    He, Bai
    Zhou, Yin
    Yang, Jun-jie
    Hou, Xiao-ling
    Yang, Xiao-bo
    Chen, Jiu-hong
    Chen, Yun-dai
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06): : 1341 - 1349
  • [39] Computed tomography coronary angiography with a consistent dose below 2 mSv using double prospectively ECG-triggered high-pitch spiral acquisition in patients with atrial fibrillation: initial experience
    Qi Wang
    Jing Qin
    Bai He
    Yin Zhou
    Jun-jie Yang
    Xiao-ling Hou
    Xiao-bo Yang
    Jiu-hong Chen
    Yun-dai Chen
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1341 - 1349
  • [40] Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience
    Wang, Q.
    Qin, J.
    He, B.
    Zhou, Y.
    Yang, J-J
    Hou, X. -L.
    Yang, X. -B.
    Chen, J. -H.
    Chen, Y. -D.
    CLINICAL RADIOLOGY, 2013, 68 (08) : 792 - 798