Evaluation of High-Pitch Ungated Pediatric Cardiovascular Computed Tomography for the Assessment of Cardiac Structures in Neonates

被引:13
|
作者
Sriharan, Mona [1 ]
Lazoura, Olga [1 ]
Pavitt, Christopher W. [1 ,2 ,4 ]
Castellano, Isabel [3 ]
Owens, Catherine M.
Rubens, Michael B. [1 ,5 ]
Padley, Simon P. G. [1 ,5 ]
Nicol, Edward D. [1 ,2 ,5 ]
机构
[1] Royal Brompton Hosp, Dept Radiol, Sydney St, London SW3 6NP, England
[2] Royal Brompton Hosp, Dept Cardiol, Sydney St, London SW3 6NP, England
[3] Royal Marsden, Joint Dept Phys, Fulham Rd, London, England
[4] Great Ormond St Hosp Sick Children, Dept Radiol, Great Ormond St, London WC1N 3JH, England
[5] Univ London Imperial Coll Sci Technol & Med, Fac Med, Natl Heart & Lung Inst, London, England
关键词
multidetector computed tomography; radiation dose; pediatric cardiac computed tomography; CONGENITAL HEART-DISEASE; DUAL-SOURCE CT; MULTIDETECTOR-ROW CT; IMAGE QUALITY; SPIRAL CT; CHILDREN; ANGIOGRAPHY; DIAGNOSIS; ARTERIES; INFANTS;
D O I
10.1097/RTI.0000000000000201
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We evaluated a high-pitch, non-electrocardiogram-gated cardiac computed tomographic protocol, designed to image both cardiac and extracardiac structures, including coronary arteries, in a neonatal population (less than 1 year old) that was referred for congenital heart disease assessment and compared it with an optimized standard-pitch protocol in an equivalent cohort. Materials and Methods: Twenty-nine high-pitch scans were compared with 31 age-matched, sex-matched, and weight-matched standard-pitch, dosimetrically equivalent scans. The visualization and subjective quality of both cardiac and extracardiac structures were scored by consensus between 2 trained blinded observers. Image noise, signal-to-noise and contrast-to-noise ratios, and radiation doses were also compared. Results: The high-pitch protocol better demonstrated the pulmonary veins (P = 0.03) and all coronary segments (all P < 0.05), except the distal right coronary artery (P = 0.10), with no significant difference in the visualization of the remaining cardiac or extracardiac structures. Both contrast-to-noise and signal-to-noise ratios improved due to greater vessel opacity, with significantly fewer streak (P < 0.01) and motion (P < 0.01) artifacts. Image noise and computed tomographic dose index were comparable across the 2 techniques; however, the high-pitch acquisition resulted in a small, but statistically significant, increase in dose-length product [13.0 mGy.cm (9.0 to 17.3) vs. 11.0 mGy.cm (9.0 to 13.0), P = 0.05] due to greater z-overscanning. Conclusions: In neonates, a high-pitch protocol improves coronary artery and pulmonary vein delineation compared with the standard-pitch protocol, allowing a more comprehensive assessment of cardiovascular anatomy while obviating the need for either patient sedation or heart rate control.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 50 条
  • [1] High-Pitch Dual Spiral Cardiovascular Computed Tomography
    Hetterich H.
    Wirth S.
    Johnson T.R.
    Bamberg F.
    Current Cardiovascular Imaging Reports, 2013, 6 (3) : 251 - 258
  • [2] High-Pitch Spiral Computed Tomography Effect on Image Quality and Radiation Dose in Pediatric Chest Computed Tomography
    Lell, Michael M.
    May, Matthias
    Deak, Paul
    Alibek, Sedat
    Kuefner, Michael
    Kuettner, Axel
    Koehler, Henrik
    Achenbach, Stephan
    Uder, Michael
    Radkow, Tanja
    INVESTIGATIVE RADIOLOGY, 2011, 46 (02) : 116 - 123
  • [3] Utility of Low-dose High-pitch Scanning for Pediatric Cardiac Computed Tomographic Imaging
    Long, Christopher M.
    Long, Svati S.
    Johnson, Pamela T.
    Mahesh, Mahadevappa
    Fishman, Elliot K.
    Zimmerman, Stefan L.
    JOURNAL OF THORACIC IMAGING, 2015, 30 (04) : W36 - W40
  • [4] Contrast-Enhanced High-Pitch Computed Tomography in Pediatric Patients Without Electrocardiography Triggering and Sedation: Comparison of Cardiac Image Quality With Conventional Multidetector Computed Tomography
    Esser, Michael
    Gatidis, Sergios
    Teufel, Matthias
    Ketelsen, Ines
    Nikolaou, Konstantin
    Schaefer, Juergen F.
    Tsiflikas, Ilias
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (01) : 165 - 171
  • [5] Image Quality of ECG-Triggered High-Pitch, Dual-Source Computed Tomography Angiography for Cardiovascular Assessment in Children
    Barrera, Christian A.
    Otero, Hansel J.
    White, Ammie M.
    Saul, David
    Biko, David M.
    CURRENT PROBLEMS IN DIAGNOSTIC RADIOLOGY, 2020, 49 (01) : 23 - 28
  • [6] Computed Tomography of the Lung in the High-Pitch Mode Is Breath Holding Still Required?
    Baumueller, Stephan
    Alkadhi, Hatem
    Stolzmann, Paul
    Frauenfelder, Thomas
    Goetti, Robert
    Schertler, Thomas
    Plass, Andre
    Falk, Volkmar
    Feuchtner, Gudrun
    Scheffel, Hans
    Desbiolles, Lotus
    Leschka, Sebastian
    INVESTIGATIVE RADIOLOGY, 2011, 46 (04) : 240 - 245
  • [7] High-Pitch Electrocardiogram-Triggered Computed Tomography of the Chest Initial Results
    Lell, Michael
    Hinkmann, Fabian
    Anders, Katharina
    Deak, Paul
    Kalender, Willi A.
    Uder, Michael
    Achenbach, Stephan
    INVESTIGATIVE RADIOLOGY, 2009, 44 (11) : 728 - 733
  • [8] High-pitch, Dual-source Chest Computed Tomography Angiography Without Electrocardiographic Synchronization Evaluation of Cardiac Motion Artifacts on Pulmonary Circulation
    Tacelli, Nunzia
    Darchis, Christine
    Pontana, Francois
    Faivre, Jean-Baptiste
    Deken, Valerie
    Duhamel, Alain
    Murphy, Colm
    Remy, Jacques
    Remy-Jardin, Martine
    JOURNAL OF THORACIC IMAGING, 2013, 28 (06) : 376 - 382
  • [10] High-pitch Dual-source Computed Tomography Pulmonary Angiography in Freely Breathing Patients
    Bauer, Ralf W.
    Schell, Boris
    Beeres, Martin
    Wichmann, Julian L.
    Bodelle, Boris
    Vogl, Thomas J.
    Kerl, Josef Matthias
    JOURNAL OF THORACIC IMAGING, 2012, 27 (06) : 376 - 381