Evaluation of High-Pitch Ungated Pediatric Cardiovascular Computed Tomography for the Assessment of Cardiac Structures in Neonates
被引:13
|作者:
Sriharan, Mona
[1
]
Lazoura, Olga
[1
]
Pavitt, Christopher W.
[1
,2
,4
]
Castellano, Isabel
[3
]
Owens, Catherine M.
Rubens, Michael B.
[1
,5
]
Padley, Simon P. G.
[1
,5
]
Nicol, Edward D.
[1
,2
,5
]
机构:
[1] Royal Brompton Hosp, Dept Radiol, Sydney St, London SW3 6NP, England
[2] Royal Brompton Hosp, Dept Cardiol, Sydney St, London SW3 6NP, England
[3] Royal Marsden, Joint Dept Phys, Fulham Rd, London, England
[4] Great Ormond St Hosp Sick Children, Dept Radiol, Great Ormond St, London WC1N 3JH, England
[5] Univ London Imperial Coll Sci Technol & Med, Fac Med, Natl Heart & Lung Inst, London, England
关键词:
multidetector computed tomography;
radiation dose;
pediatric cardiac computed tomography;
CONGENITAL HEART-DISEASE;
DUAL-SOURCE CT;
MULTIDETECTOR-ROW CT;
IMAGE QUALITY;
SPIRAL CT;
CHILDREN;
ANGIOGRAPHY;
DIAGNOSIS;
ARTERIES;
INFANTS;
D O I:
10.1097/RTI.0000000000000201
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: We evaluated a high-pitch, non-electrocardiogram-gated cardiac computed tomographic protocol, designed to image both cardiac and extracardiac structures, including coronary arteries, in a neonatal population (less than 1 year old) that was referred for congenital heart disease assessment and compared it with an optimized standard-pitch protocol in an equivalent cohort. Materials and Methods: Twenty-nine high-pitch scans were compared with 31 age-matched, sex-matched, and weight-matched standard-pitch, dosimetrically equivalent scans. The visualization and subjective quality of both cardiac and extracardiac structures were scored by consensus between 2 trained blinded observers. Image noise, signal-to-noise and contrast-to-noise ratios, and radiation doses were also compared. Results: The high-pitch protocol better demonstrated the pulmonary veins (P = 0.03) and all coronary segments (all P < 0.05), except the distal right coronary artery (P = 0.10), with no significant difference in the visualization of the remaining cardiac or extracardiac structures. Both contrast-to-noise and signal-to-noise ratios improved due to greater vessel opacity, with significantly fewer streak (P < 0.01) and motion (P < 0.01) artifacts. Image noise and computed tomographic dose index were comparable across the 2 techniques; however, the high-pitch acquisition resulted in a small, but statistically significant, increase in dose-length product [13.0 mGy.cm (9.0 to 17.3) vs. 11.0 mGy.cm (9.0 to 13.0), P = 0.05] due to greater z-overscanning. Conclusions: In neonates, a high-pitch protocol improves coronary artery and pulmonary vein delineation compared with the standard-pitch protocol, allowing a more comprehensive assessment of cardiovascular anatomy while obviating the need for either patient sedation or heart rate control.
引用
收藏
页码:177 / 182
页数:6