High-Pitch Electrocardiogram-Triggered Computed Tomography of the Chest Initial Results

被引:67
|
作者
Lell, Michael [1 ]
Hinkmann, Fabian [1 ]
Anders, Katharina [1 ]
Deak, Paul [2 ]
Kalender, Willi A. [2 ]
Uder, Michael [1 ]
Achenbach, Stephan [3 ]
机构
[1] Univ Erlangen Nurnberg, Dept Radiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Med Phys, D-91054 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
关键词
computed tomography; pulmonary embolism; aortic dissection; coronary CT angiography; dual source CT; radiation exposure; CORONARY CT ANGIOGRAPHY; TRIPLE RULE-OUT; DUAL-SOURCE CT; IMAGE QUALITY; NONCARDIAC FINDINGS; RADIATION-EXPOSURE; MULTISLICE CT; HEART-RATES; RECONSTRUCTION; PREVALENCE;
D O I
10.1097/RLI.0b013e3181b9df7e
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: Chest pain is one of the most frequent symptoms in the emergency department. A variety of different diseases, some of them acutely life threatening, can be the underlying cause. Electrocardiogram (ECG)gated computed tomography angiography of the thorax has been proposed as a cost and time effective imaging technique for these patients. We describe a new high-pitch scan mode, which has been developed specifically for low-dose ECG-triggered computed tomography angiography using dual source computed tomography (CT). Material and Methods: Twenty-four patients were examined with this technique on a second generation dual source CT system. The scan mode uses a pitch of 3.2 to acquire a spiral CT data set of the complete thorax in less than I second with a temporal resolution of 75 ms (scan parameters: 128 X 0.6 mm collimation, 0.28 seconds gantry rotation time, 370 mAs at 100 kV [15 patients] and 320 mAs at 120 kV [9 patients], reconstructed slice thickness 0.6 mm, increment 0.4 mm). Data acquisition was prospectively triggered at 50% to 60% of the RR interval to cover the range over the heart in diastole. A triple phase contrast injection protocol (total volume: 80 mL) was used to optimize enhancement of the pulmonary and systemic arterial vessels. Image quality was evaluated using a 4-point scale (1 = absence of motion artifacts; 2 = slight motion artifacts, fully evaluable; 3 = motion artifacts, but evaluable; 4 = unevaluable) on a per-segment basis. Results: The patients had an average heart rate of 68 +/- 15 bpm (range: 43-111 bpm) during data acquisition. Motion artifact free visualization of the aorta and pulmonary vessels was possible in each case, of 344 coronary artery segments, 242 (70%) had an image quality score of 1, 60 segments (17%) a score of 2, 28 segments (8%) a score of 3, and 14 segments (4%) were rated as "unevaluable." In 17 patients (10 patients with a heart rate <= 60 bpm) all segments were evaluable. The average dose length product was 113 +/- 11 mGy x cm per scan (mean effective dose 1.6 +/- 0.2 mSv) at 100 kV and 229 +/- 31 mGy x cm per scan (mean effective dose 3.2 +/- 0.4 mSv) at 120 kV. Conclusion: Our initial results indicate that this high-pitch scan mode allows motion artifact free and accurate visualization of the thoracic vessels, and diagnostic image quality of the coronary arteries in patients with low and stable heart rates at a very low radiation exposure.
引用
收藏
页码:728 / 733
页数:6
相关论文
共 50 条
  • [1] Safety and efficacy of intravenous esmolol before prospective electrocardiogram-triggered high-pitch spiral acquisition for computed tomography coronary angiography
    Jin-Da WANG
    Hua-Wei ZHANG
    Qian XIN
    Jun-Jie YANG
    Zhi-Jun SUN
    Hong-Bin LIU
    Lian CHEN
    Luo-Shan DU
    Yun-Dai CHEN
    Journal of Geriatric Cardiology, 2014, 11 (01) : 39 - 43
  • [2] Prospectively electrocardiogram-triggered high-pitch spiral acquisition Coronary Computed Tomography Angiography for assessment of BVS expansion: comparison with Optical Coherence Tomography
    Mattesini, Alessio
    D'Alfonso, Maria G.
    Meucci, Francesco
    Gensini, Gian Franco
    Di Mario, Carlo
    Valente, Serafina
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B87 - B88
  • [3] Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition
    Achenbach, Stephan
    Marwan, Mohamed
    Ropers, Dieter
    Schepis, Tiziano
    Pflederer, Tobias
    Anders, Katharina
    Kuettner, Axel
    Daniel, Werner G.
    Uder, Michael
    Lell, Michael M.
    EUROPEAN HEART JOURNAL, 2010, 31 (03) : 340 - 346
  • [4] Prospectively electrocardiogram-triggered high-pitch spiral acquisition coronary computed tomography angiography for assessment of biodegradable vascular scaffold expansion: Comparison with optical coherence tomography
    D'Alfonso, Maria Grazia
    Mattesini, Alessio
    Meucci, Francesco
    Acquafresca, Manlio
    Gensini, Gian Franco
    Valente, Serafina
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2014, 15 (08) : 436 - 438
  • [5] Non-Electrocardiogram-Triggered 70-kVp High-Pitch Computed Tomography Angiography of the Whole Aorta With Iterative Reconstruction: Initial Results
    Zhang, Long Jiang
    Li, Xie
    Schoepf, U. Joseph
    Wichmann, Julian L.
    Tang, Chun Xiang
    Zhou, Chang Sheng
    Lu, Guang Ming
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (01) : 109 - 117
  • [6] Visualization of proximal coronary arteries on high-pitch electrocardiogram-triggered computed tomography in pediatric congenital heart disease: effects of heart rate and body surface area
    LaDonna J. Malone
    Andrew Olson
    Alex J. Barker
    David Andrew Mong
    Jason P. Weinman
    Lorna P. Browne
    Pediatric Radiology, 2020, 50 : 1375 - 1380
  • [7] Visualization of proximal coronary arteries on high-pitch electrocardiogram-triggered computed tomography in pediatric congenital heart disease: effects of heart rate and body surface area
    Malone, LaDonna J.
    Olson, Andrew
    Barker, Alex J.
    Mong, David Andrew
    Weinman, Jason P.
    Browne, Lorna P.
    PEDIATRIC RADIOLOGY, 2020, 50 (10) : 1375 - 1380
  • [8] High-Pitch Spiral Computed Tomography Effect on Image Quality and Radiation Dose in Pediatric Chest Computed Tomography
    Lell, Michael M.
    May, Matthias
    Deak, Paul
    Alibek, Sedat
    Kuefner, Michael
    Kuettner, Axel
    Koehler, Henrik
    Achenbach, Stephan
    Uder, Michael
    Radkow, Tanja
    INVESTIGATIVE RADIOLOGY, 2011, 46 (02) : 116 - 123
  • [9] Safety and efficacy of intravenous esmolol before prospective electrocardiogram- triggered high-pitch spiral acquisition for computed tomography coronary angiography
    Wang, Jin-Da
    Zhang, Hua-Wei
    Xin, Qian
    Yang, Jun-Jie
    Sun, Zhi-Jun
    Liu, Hong-Bin
    Chen, Lian
    Du, Luo-Shan
    Chen, Yun-Dai
    JOURNAL OF GERIATRIC CARDIOLOGY, 2014, 11 (01) : 39 - 43
  • [10] High-Pitch Dual Spiral Cardiovascular Computed Tomography
    Hetterich H.
    Wirth S.
    Johnson T.R.
    Bamberg F.
    Current Cardiovascular Imaging Reports, 2013, 6 (3) : 251 - 258