Evaluation of High-Pitch Ungated Pediatric Cardiovascular Computed Tomography for the Assessment of Cardiac Structures in Neonates

被引:13
|
作者
Sriharan, Mona [1 ]
Lazoura, Olga [1 ]
Pavitt, Christopher W. [1 ,2 ,4 ]
Castellano, Isabel [3 ]
Owens, Catherine M.
Rubens, Michael B. [1 ,5 ]
Padley, Simon P. G. [1 ,5 ]
Nicol, Edward D. [1 ,2 ,5 ]
机构
[1] Royal Brompton Hosp, Dept Radiol, Sydney St, London SW3 6NP, England
[2] Royal Brompton Hosp, Dept Cardiol, Sydney St, London SW3 6NP, England
[3] Royal Marsden, Joint Dept Phys, Fulham Rd, London, England
[4] Great Ormond St Hosp Sick Children, Dept Radiol, Great Ormond St, London WC1N 3JH, England
[5] Univ London Imperial Coll Sci Technol & Med, Fac Med, Natl Heart & Lung Inst, London, England
关键词
multidetector computed tomography; radiation dose; pediatric cardiac computed tomography; CONGENITAL HEART-DISEASE; DUAL-SOURCE CT; MULTIDETECTOR-ROW CT; IMAGE QUALITY; SPIRAL CT; CHILDREN; ANGIOGRAPHY; DIAGNOSIS; ARTERIES; INFANTS;
D O I
10.1097/RTI.0000000000000201
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We evaluated a high-pitch, non-electrocardiogram-gated cardiac computed tomographic protocol, designed to image both cardiac and extracardiac structures, including coronary arteries, in a neonatal population (less than 1 year old) that was referred for congenital heart disease assessment and compared it with an optimized standard-pitch protocol in an equivalent cohort. Materials and Methods: Twenty-nine high-pitch scans were compared with 31 age-matched, sex-matched, and weight-matched standard-pitch, dosimetrically equivalent scans. The visualization and subjective quality of both cardiac and extracardiac structures were scored by consensus between 2 trained blinded observers. Image noise, signal-to-noise and contrast-to-noise ratios, and radiation doses were also compared. Results: The high-pitch protocol better demonstrated the pulmonary veins (P = 0.03) and all coronary segments (all P < 0.05), except the distal right coronary artery (P = 0.10), with no significant difference in the visualization of the remaining cardiac or extracardiac structures. Both contrast-to-noise and signal-to-noise ratios improved due to greater vessel opacity, with significantly fewer streak (P < 0.01) and motion (P < 0.01) artifacts. Image noise and computed tomographic dose index were comparable across the 2 techniques; however, the high-pitch acquisition resulted in a small, but statistically significant, increase in dose-length product [13.0 mGy.cm (9.0 to 17.3) vs. 11.0 mGy.cm (9.0 to 13.0), P = 0.05] due to greater z-overscanning. Conclusions: In neonates, a high-pitch protocol improves coronary artery and pulmonary vein delineation compared with the standard-pitch protocol, allowing a more comprehensive assessment of cardiovascular anatomy while obviating the need for either patient sedation or heart rate control.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 50 条
  • [21] Motion Artifact Reduction From High-Pitch Dual-Source Computed Tomography Pulmonary Angiography
    Bunch, Paul M.
    Fulwadhva, Urvi P.
    Wortman, Jeremy R.
    Primak, Andrew N.
    Madan, Rachna
    Steigner, Michael L.
    Sodickson, Aaron D.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (04) : 623 - 629
  • [22] Image quality and radiation dose of ECG-triggered High-Pitch Dual-Source cardiac computed tomography angiography in children for the evaluation of central vascular stents
    Barrera, Christian A.
    Otero, Hansel J.
    White, Ammie M.
    Saul, David
    Biko, David M.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (02): : 367 - 374
  • [23] Image quality and radiation dose of ECG-triggered High-Pitch Dual-Source cardiac computed tomography angiography in children for the evaluation of central vascular stents
    Christian A. Barrera
    Hansel J. Otero
    Ammie M. White
    David Saul
    David M. Biko
    The International Journal of Cardiovascular Imaging, 2019, 35 : 367 - 374
  • [24] Evaluation of ECG-Gated, High-Pitch Thoracoabdominal Angiographies With Dual-Source Photon-Counting Detector Computed Tomography
    Rippel, K.
    Luitjens, J.
    Habeeballah, O.
    Scheurig-Muenkler, C.
    Bette, Stefanie
    Braun, Franziska
    Kroencke, T. J.
    Schwarz, F.
    Decker, J. A.
    JOURNAL OF ENDOVASCULAR THERAPY, 2024,
  • [25] Dose and image quality of high-pitch dual source computed tomography for the evaluation of cervical lymph node status - Comparison to regular 128-slice single source computed tomography
    Bodelle, Boris
    Bauer, Ralf W.
    Holthaus, Lara
    Schulz, Boris
    Al-Butmeh, Firas
    Wichmann, Julian L.
    Beeres, Martin
    Vogl, Thomas J.
    Kerl, J. Matthias
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (06) : E281 - E285
  • [26] Evaluation of valvular disease by cardiac computed tomography assessment
    Buttan, Anshu K.
    Yang, Eric H.
    Budoff, Matthew J.
    Vorobiof, Gabriel
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 381 - 392
  • [27] Never forget the abdomen in the evaluation of pediatric cardiac computed tomography
    Fu, Chun-Min
    Chen, Shyh-Jye
    Lu, Chun-Wei
    Chen, Chun-An
    Chiu, Shuenn-Nan
    Lin, Ming-Tai
    Hsieh, Wu-Shiun
    Wang, Jou-Kou
    Wu, Mei-Hwan
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 157 (02) : E31 - E32
  • [28] Sensitivity of High-Pitch Dual-Source Computed Tomography for the Detection of Anomalous Pulmonary Venous Connection in Infants
    Well, Lennart
    Weinrich, Julius Matthias
    Meyer, Mathias
    Kehl, Torben
    Salamon, Johannes
    Rueffer, Andre
    Adam, Gerhard
    Herrmann, Jochen
    Groth, Michael
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (05): : 551 - 558
  • [29] Determination of anomalous pulmonary venous return with high-pitch low-dose computed tomography in paediatric patients
    Gozgec, E.
    Kantarci, M.
    Guven, F.
    Ogul, H.
    Ceviz, N.
    Eren, S.
    FOLIA MORPHOLOGICA, 2021, 80 (02) : 336 - 343
  • [30] Radiation doses from phantom measurements at high-pitch dual-source computed tomography coronary angiography
    Goetti, Robert
    Leschka, Sebastian
    Boschung, Markus
    Mayer, Sabine
    Wyss, Christophe
    Stolzmann, Paul
    Frauenfelder, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : 773 - 779