Investigation of radiation doses in open space using TLD detectors

被引:10
|
作者
Reitz, G [1 ]
Facius, R
Bilski, P
Olko, P
机构
[1] DLR, Cologne, Germany
[2] Inst Nucl Phys, Krakow, Poland
关键词
D O I
10.1093/oxfordjournals.rpd.a005930
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The low energy component of the cosmic radiation field is strongly modified by the shielding of the spacecraft and it is time and location dependent. Thermoluminescent lithium fluoride detectors have been applied to determine the radiation doses inside the ESA-Facility BIOPAN. The BIOPAN facility was mounted outside and launched on a Felon spacecraft and opened to space to allow exposure of several experiments to open space. Standard TLD-600, TLD-700 chips, two layers MTS-Ns sintered pellets with different effective thickness of the sensitive layer and MTS-N of different thickness have been exposed with different shielding thicknesses in front of them. The Measured TL signal in the 0.1 mm thick detector just shielded by an aluminised Kapton foil of 25 mum thickness in front yielded a dose of 29.8 Gy (calibrated with Cs-137 gaming rays) for an exposure time of 12.7 days: after 2.5 g.cm(-2) shielding the doses dropped to 3 mGy. The monitoring of radiation doses and its depth dose distribution outside the spacecraft are of great interest for radiation protection of astronauts working in open space. The knowledge of depth-dose distribution is a prerequisite to determine the organ doses an astronaut will receive during an extravehicular activity (EVA). The BIOPAN experiments are to be continued in the future.
引用
收藏
页码:533 / 536
页数:4
相关论文
共 50 条
  • [21] Radiation doses at high altitudes and during space flights
    Spurny, F
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 301 - 307
  • [22] Type-testing of the TLD system used for the assessing the eye lens doses due to ionising radiation
    Petrovic, Jelena Stankovic
    Danilovic, Natasa
    Krzanovic, Nikola
    Topalovic, Dusan
    Zivanovic, Milos
    Bozovic, Predrag
    Todorovic, Natasa
    Nikolov, Jovana
    RADIATION MEASUREMENTS, 2023, 168
  • [23] MEASUREMENT OF HIGH GAMMA-RADIATION DOSES RANGING FROM 0.02 TO 250 MRAD USING PLASTIC DETECTORS
    DASILVA, H
    MARTINHO, E
    RADIATION PHYSICS AND CHEMISTRY, 1983, 22 (3-5): : 315 - 324
  • [24] Investigation of basic characteristics of synthetic diamond radiation detectors
    Kashiwagi, T
    Hibino, K
    Kitamura, H
    Mori, K
    Okuno, S
    Takashima, T
    Uchihori, Y
    Yajima, K
    Yokota, M
    Yoshida, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (02) : 630 - 635
  • [25] Investigation of basic characteristics of synthetic diamond radiation detectors
    Kashiwagi, T
    Hibino, K
    Kitamura, H
    Okuno, S
    Takashima, T
    Uchihori, Y
    Yajima, K
    Yokota, M
    Yoshida, K
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 734 - 738
  • [26] FOXFET BIASED MICROSTRIP DETECTORS - AN INVESTIGATION OF RADIATION SENSITIVITY
    BACCHETTA, N
    BISELLO, D
    CANALI, C
    DAROS, R
    GIRALDO, A
    GOTRA, Y
    PACCAGNELLA, A
    PIACENTINO, GM
    VERZELLESI, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 342 (01): : 39 - 48
  • [27] Investigation of the radiation damage of GaAs detectors by neutrons and photons
    Braunschweig, W
    Kubicki, T
    Lubelsmeyer, K
    Pandoulas, D
    Syben, O
    Tenbusch, F
    Toporowsky, M
    Wilms, T
    Wittmer, B
    Xiao, WJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 372 (1-2): : 111 - 116
  • [28] Investigation of the Charge Collection Efficiency of CdMnTe Radiation Detectors
    Rafiei, R.
    Boardman, D.
    Sarbutt, A.
    Prokopovich, D. A.
    Kim, K.
    Reinhard, M. I.
    Bolotnikov, A. E.
    James, R. B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (03) : 634 - 641
  • [29] ABSORBER FOR MICROWAVE INVESTIGATION IN THE OPEN SPACE
    Kubacki, Roman
    Smolski, Boguslaw
    Gluszewski, Wojciech
    Przesmycki, Rafal
    Rudyk, Karol
    XI CONFERENCE ON RECONNAISSANCE AND ELECTRONIC WARFARE SYSTEMS, 2017, 10418
  • [30] Response of TL lithium fluoride detectors (MTS) to high gamma radiation doses
    Khoury, H. J.
    Obryk, B.
    Barros, V. S.
    Guzzo, P. L.
    Ferreira, C. G.
    Bilski, P.
    Olko, P.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1878 - 1881