BACKGROUND AND PURPOSE: The purpose of this study was to compare obtained packing densities of aneurysms treated with the newly introduced GDC 360 degrees coils with packing densities of aneurysms treated with either complex Orbit/Trufill coils or helical GDC 10 coils. PATIENTS AND METHODS: Twenty-two aneurysms in 20 patients were coiled with GDC 360 degrees coils. For each of the 22 aneurysms coiled with GDC 360 degrees coils, 2 volume-matched controls treated with either complex Orbit/Trufill coils or helical GDC coils were identified from our data base. The packing of these matched controls was compared with the calculated packing of the 22 aneurysms treated with GDC 360 degrees coils. RESULTS: There was no difference in mean aneurysm volume between aneurysms treated with any of the 3 types of coils (P = .9). Mean packing of 22.1 % of aneurysms treated with GDC 360 degrees coils was significantly lower than mean packing of 30.3% of aneurysms treated with complex Orbit/Trufill coils (P = .0015). Mean packing of 22.1 % of aneurysms treated with GDC 360 degrees coils was not different from mean packing of 21.6% of aneurysms treated with helical GDC 10 coils (P = .81). CONCLUSION: The use of complex-shaped GDC 360 degrees coils does not lead to increased packing in comparison with that of helical GDC 10 coils. The use of complex Orbit/Trufill coils results in significantly higher packing than that of both GDC 360 degrees coils and helical GDC 10 coils.
引用
收藏
页码:368 / 370
页数:3
相关论文
共 50 条
  • [31] Coil Protection Using Small Helical Coils for Wide-Neck Intracranial Aneurysms: A Novel Approach
    Cho, Y. D.
    Lee, J. Y.
    Seo, J. H.
    Lee, S. J.
    Kang, H. -S.
    Kim, J. E.
    Kwon, O-K
    Son, Y. J.
    Han, M. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (01) : 164 - 168
  • [32] Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils - Effects on packing density, coil length and quantity, procedure performance, cost, length of hospital stay, and durability of therapy
    Gaba, RC
    Ansari, SA
    Roy, SS
    Marden, FA
    Viana, MAG
    Malisch, TW
    STROKE, 2006, 37 (06) : 1443 - 1450
  • [33] Endovascular Occlusion of Intracranial Aneurysms with Guglielmi Detachable Coils: Correlation Between Coil Packing Density and Coil Compaction
    Y. Kawanabe
    A. Sadato
    W. Taki
    N. Hashimoto
    Acta Neurochirurgica, 2001, 143 : 451 - 455
  • [34] Influence of coil thickness on packing, reopening and retreatment of intracranial aneurysms: A comparative study between two types of coils
    Slob, MJ
    van Rooij, WJ
    Sluzewski, M
    RIVISTA DI NEURORADIOLOGIA, 2005, 18 : 39 - 43
  • [35] Endovascular occlusion of intracranial aneurysms with Guglielmi detachable coils: Correlation between coil packing density and coil compaction
    Kawanabe, Y
    Sadato, A
    Taki, W
    Hashimoto, N
    ACTA NEUROCHIRURGICA, 2001, 143 (05) : 451 - 455
  • [36] Endovascular Treatment of Unruptured Intracranial Aneurysms: Comparison of Safety of Remodeling Technique and Standard Treatment with Coils
    Pierot, Laurent
    Spelle, Laurent
    Leclerc, Xavier
    Cognard, Christophe
    Bonafe, Alain
    Moret, Jacques
    RADIOLOGY, 2009, 251 (03) : 846 - 855
  • [37] Performance of long J-shaped coils in large and giant intracranial aneurysms:: an in vitro study
    Tokunaga, K
    Tanaka, N
    Sugiu, K
    Levrier, O
    Martin, JB
    Rüfenacht, DA
    NEURORADIOLOGY, 2002, 44 (03) : 261 - 267
  • [38] Performance of long J-shaped coils in large and giant intracranial aneurysms: an in vitro study
    K. Tokunaga
    N. Tanaka
    K. Sugiu
    O. Levrier
    J. Martin
    D. Rüfenacht
    Neuroradiology, 2002, 44 : 261 - 267
  • [39] Midterm prevention of rebleeding by Guglielmi detachable coils in ruptured intracranial aneurysms less than 10 mm
    Kawabe, T
    Tenjin, H
    Hayashi, Y
    Kakita, K
    Kubo, S
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2006, 108 (02) : 163 - 167