Packing performance of GDC 360° coils in intracranial aneurysms:: A comparison with complex Orbit coils and helical GDC 10 coils

被引:0
|
作者
van Rooij, W. J. [1 ]
Sluzewski, M. [1 ]
机构
[1] St Elizabeth Hosp, Dept Radiol, NL-5022 GC Tilburg, Netherlands
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The purpose of this study was to compare obtained packing densities of aneurysms treated with the newly introduced GDC 360 degrees coils with packing densities of aneurysms treated with either complex Orbit/Trufill coils or helical GDC 10 coils. PATIENTS AND METHODS: Twenty-two aneurysms in 20 patients were coiled with GDC 360 degrees coils. For each of the 22 aneurysms coiled with GDC 360 degrees coils, 2 volume-matched controls treated with either complex Orbit/Trufill coils or helical GDC coils were identified from our data base. The packing of these matched controls was compared with the calculated packing of the 22 aneurysms treated with GDC 360 degrees coils. RESULTS: There was no difference in mean aneurysm volume between aneurysms treated with any of the 3 types of coils (P = .9). Mean packing of 22.1 % of aneurysms treated with GDC 360 degrees coils was significantly lower than mean packing of 30.3% of aneurysms treated with complex Orbit/Trufill coils (P = .0015). Mean packing of 22.1 % of aneurysms treated with GDC 360 degrees coils was not different from mean packing of 21.6% of aneurysms treated with helical GDC 10 coils (P = .81). CONCLUSION: The use of complex-shaped GDC 360 degrees coils does not lead to increased packing in comparison with that of helical GDC 10 coils. The use of complex Orbit/Trufill coils results in significantly higher packing than that of both GDC 360 degrees coils and helical GDC 10 coils.
引用
收藏
页码:368 / 370
页数:3
相关论文
共 50 条
  • [21] Embolization of intracranial aneurysms with hydrogel-coated coils versus inert platinum coils: Effects on packing density, coil length and quantity, procedure performance, and cost
    Gaba, RC
    Ansari, SA
    Roy, SS
    Marden, FA
    Viana, MAG
    Charbel, FT
    Amin-Hanjani, S
    Malisch, TW
    JOURNAL OF NEUROSURGERY, 2005, 102 (02) : A420 - A420
  • [22] Clinical experience with Matrix2 360° coils in the treatment of 100 intracranial aneurysms
    D'Agostino, Sabino J.
    Harrigan, Mark R.
    Chalela, Julio A.
    Nicholas, Joyce S.
    Deveikis, Susan I.
    Jones, Tanya M.
    Deveikis, John P.
    SURGICAL NEUROLOGY, 2009, 72 (01): : 41 - 47
  • [23] Surveillance of intracranial aneurysms treated with detachable coils: a comparison of MRA techniques
    Richard I. Farb
    Shudeshna Nag
    James N. Scott
    Robert A. Willinsky
    Thomas R. Marotta
    Walter J. Montanera
    George Tomlinson
    Karel G. terBrugge
    Neuroradiology, 2005, 47 : 507 - 515
  • [24] Surveillance of intracranial aneurysms treated with detachable coils: a comparison of MRA techniques
    Farb, RI
    Nag, S
    Scott, JN
    Willinsky, RA
    Marotta, TR
    Montanera, WJ
    Tomlinson, G
    terBrugge, KG
    NEURORADIOLOGY, 2005, 47 (07) : 507 - 515
  • [25] Increasing the packing of small aneurysms with complex-shaped coils: An in vitro study
    Piotin, M
    Iijima, A
    Wada, H
    Moret, J
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2003, 24 (07) : 1446 - 1448
  • [26] Single-institution experience with Matrix coils in the treatment of intracranial aneurysms: Comparison with same-center outcomes with the use of platinum coils
    Rivet, D. J.
    Moran, C. J.
    Mazumdar, A.
    Pilgram, T. K.
    Derdeyn, C. P.
    Cross, D. T.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (09) : 1736 - 1742
  • [27] Histopathologic findings in cerebral artery aneurysms after embolization with Guglielmi detachable platinum coils (GDC): report of two cases
    Romeike, BFM
    Niedermayer, I
    Feiden, W
    RADIOLOGE, 1999, 39 (10): : 900 - 903
  • [28] Ultrashort T-E time-of-flight MR angiography improves the follow-up of intracranial aneurysms treated with Guglielmi detachable coils (GDC)
    Gonner, F
    Heid, O
    Nicoli, G
    Remonda, L
    Schroth, G
    Seiler, RW
    11TH INTERNATIONAL CONGRESS OF NEUROLOGICAL SURGERY, VOLS 1 AND 2, 1997, : 957 - 962
  • [29] Endovascular treatment of intracranial aneurysms with detachable coils: correlation between aneurysm volume, packing, and angiographic recurrence
    Leng, Bing
    Zheng, Yongtao
    Ren, Jinma
    Xu, Qiang
    Tian, Yanlong
    Xu, Feng
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (08) : 595 - 599
  • [30] Cerecyte versus Platinum Coils in the Treatment of Intracranial Aneurysms: Packing Attenuation and Clinical and Angiographic Midterm Results
    Linfante, I.
    DeLeo, M. J., III
    Gounis, M. J.
    Brooks, C. S.
    Wakhloo, A. K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (08) : 1496 - 1501