Changes of insulation resistance of fire resistant cable under fire conditions

被引:0
|
作者
Polanska, M. [1 ]
Prosr, P. [2 ]
Polansky, R. [2 ]
机构
[1] Kabelovna KABEX As, Lab Thermal Analyses, Holysov, Czech Republic
[2] Univ W Bohemia, Reg Innovat Ctr Elect Engn, Plzen, Czech Republic
关键词
low-fire-hazard cable; insulation resistance; IEC; 60331-21; thermogravimetric analysis; fire retardant; ATH; FLAME-RETARDANT; NANOCOMPOSITE; POLYETHYLENE; DEGRADATION; COMPOSITES; BEHAVIOR;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Low-fire-hazard cable (LFHC) intended for low voltage applications with a fire barrier made from mica tape was tested under conditions similar to those of the fire test specified in IEC 60331-21. In addition to the other standard requirements, the measurement setup was modified to enable insulation resistance measurement throughout the entire fire test. In this manner, cable insulation as a whole can be tested under fire conditions. Results from insulation resistance measurement are supported by thermogravimetric analysis and by the data obtained from two thermocouples placed near the cable sheath and inside the cable core during the test. As results show, insulation resistance is markedly affected by the melting of the organic components of insulation, by decomposition of the flame retardant and by ignition of the core insulation along the first period of the test (10 minutes). The stable value of the insulation resistance from 10th to 90th minutes of testing, together with the insulation's behavior during cooling suggests the important role played by conductivity of the flame itself. The suggested procedure can assist in the comparison of the fire-proof functionalities of different cable designs, in the analysis of their failure mechanisms and in cable design optimization.
引用
收藏
页码:278 / 281
页数:4
相关论文
共 50 条
  • [11] Behaviour of Fire Resistant Cable Insulation with Different Flame Barriers During Water Immersion
    Packa, Juraj
    Durman, Vladimir
    Sulova, Janka
    PROCEEDINGS OF THE 2019 20TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2019, : 265 - 268
  • [12] A simplified approach for calculating fire resistance of steel frames under fire conditions
    Tan, KH
    Toh, WS
    Yuan, Z
    MECHANICS OF STRUCTURES AND MATERIALS, 1999, : 431 - 436
  • [13] The behaviour of fire resistant glass under fire
    Machalicka, K.
    Charvatova, M.
    Eliasova, M.
    Kuklik, P.
    STRUCTURES AND ARCHITECTURE: BEYOND THEIR LIMITS, 2016, : 991 - 997
  • [14] Non-halogenated cable insulation with fire retardants
    Beyer, G
    PLACE OF PLASTICS IN FIRE PREVENTION, 1999, 1483 : 263 - 278
  • [15] Insulation Failure Prediction Model of Power Cable in Fire
    Li, Jin-mei
    Zhang, Jia-qing
    Li, Qiang
    Ren, Shi-jing
    2018 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND GREEN ENERGY (CEEGE 2018), 2018, 72
  • [16] Effects of fire combustion products on degradation of cable insulation
    Dervos, CT
    Vassiliou, P
    JOURNAL OF FIRE SCIENCES, 1998, 16 (03) : 206 - 221
  • [17] Cable Insulation Properties Changes Through Nanofillers Nanoclays as a counterpart to the traditional fire retardants
    Vesely, Ondrej
    Mentlik, Vaclav
    2016 17TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2016, : 375 - 378
  • [18] FIRE RESISTANCE OF FIRE-RESISTANT STEEL COLUMNS
    SAKUMOTO, Y
    YAMAGUCHI, T
    OKADA, T
    YOSHIDA, M
    TASAKA, S
    SAITO, H
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (04): : 1103 - 1121
  • [19] Oil and Gas Structures: Forecasting the Fire Resistance of Steel Structures with Fire Protection under Hydrocarbon Fire Conditions
    Gravit, Marina
    Dmitriev, Ivan
    Shcheglov, Nikita
    Radaev, Anton
    FIRE-SWITZERLAND, 2024, 7 (06):
  • [20] FIRE-RESISTANT ISOCYANURATE FOAM INSULATION
    STEVENS, B
    CHEMICAL AND PROCESS ENGINEERING, 1972, 53 (04): : 40 - &