FIRE RESISTANCE OF FIRE-RESISTANT STEEL COLUMNS

被引:18
|
作者
SAKUMOTO, Y
YAMAGUCHI, T
OKADA, T
YOSHIDA, M
TASAKA, S
SAITO, H
机构
[1] GEN BLDG RES CORP,SUITA KU,OSAKA 565,JAPAN
[2] CHIBA UNIV,FAC ENGN,CHIBA 260,JAPAN
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 1994年 / 120卷 / 04期
关键词
D O I
10.1061/(ASCE)0733-9445(1994)120:4(1103)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper is to verify the fire resistance of columns made from fire-resistant (FR) structural steel by means of a full-scale loaded heat test and numerical analysis. Because of the elements contained, FR steel has higher strength than conventional structural steel at elevated temperatures. Its 0.2% proof stress at 600-degrees-C is equal to or greater than two-thirds the value specified at room temperature. Rock wool, ceramic fire protection, and foaming-type intumescent coating were used as fire-protection materials. Using Japanese codes. the high-temperature strength of steel can be exhibited with building members, the fire-protection thickness can be reduced below what is required for conventional steel columns, and 1-h fire resistance can be obtained by intumescent coating with a lower insulation property. Also, deformation and fire-resistance time can be simulated from the mechanical properties at elevated temperatures and elastoplastic thermal deformation analysis. Furthermore, this study is based on Japanese codes, and results will differ if based on ASTM codes.
引用
收藏
页码:1103 / 1121
页数:19
相关论文
共 50 条
  • [1] Parametric studies on fire resistance of fire-resistant steel members
    Ding, J
    Li, GQ
    Sakumoto, Y
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2004, 60 (07) : 1007 - 1027
  • [2] Buckling resistance behavior of WGJ420 fire-resistant weathering steel columns under fire
    Wu, Yiran
    Yu, Xianglin
    Shi, Yongjiu
    Xu, Yonglei
    Ban, Huiyong
    [J]. STEEL AND COMPOSITE STRUCTURES, 2023, 47 (02): : 269 - 287
  • [3] RESISTANCE OF CONCRETE-FILLED, FIRE-RESISTANT STEEL-TUBE COLUMNS
    SAKUMOTO, Y
    OKADA, T
    YOSHIDA, M
    TASAKA, S
    [J]. JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 1994, 6 (02) : 169 - 184
  • [4] Fire resistance of steel beams with integrated fire-resistant and decorative constructions
    Chu, Chengyi
    Ye, Xunan
    Fu, Bo
    Zhang, Lei
    Gao, Wang
    Fan, Dongdong
    [J]. Journal of Constructional Steel Research, 2024, 223
  • [5] Fire protection thickness of concrete-filled fire-resistant steel tubular columns
    Liu, Yi-Xiang
    Tong, Gen-Shu
    Zhang, Lei
    [J]. Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2015, 49 (12): : 2387 - 2396
  • [6] Fire-resistant design of eccentrically compressed stainless steel columns with constraints
    Liu, Meijing
    Fan, Shenggang
    Sun, Wenjun
    Ding, Runmin
    Zhu, Ting
    [J]. FIRE SAFETY JOURNAL, 2018, 100 : 1 - 19
  • [7] Fire resistance of floors constructed with fire-resistant steels
    Sha, W
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (06): : 664 - 670
  • [8] Fire resistance of floors constructed with fire-resistant steels
    Sha, Wei
    [J]. Journal of structural engineering New York, N.Y., 1998, 124 (06): : 664 - 670
  • [9] Experimental study of fire-resistant steel H-columns at elevated temperature
    Yang, KC
    Lee, HH
    Chan, O
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2006, 62 (06) : 544 - 553
  • [10] Experimental research on the creep buckling of fire-resistant steel columns at elevated temperature
    Yang, Kuo-Chen
    Yu, Zong-Han
    [J]. STEEL AND COMPOSITE STRUCTURES, 2013, 15 (02): : 163 - 173