EVALUATION OF EXPOSURE IN MAMMOGRAPHY: LIMITATIONS OF AVERAGE GLANDULAR DOSE AND PROPOSAL OF A NEW QUANTITY

被引:11
|
作者
Geeraert, N. [1 ,2 ,3 ]
Klausz, R. [2 ]
Muller, S. [2 ]
Bloch, I. [3 ]
Bosmans, H. [1 ]
机构
[1] Katholieke Univ Leuven, Dept Radiol, B-3000 Leuven, Belgium
[2] GE Healthcare, Digital Guidance Solut, F-78530 Buc, France
[3] Telecom ParisTech, Inst Mines Telecom, CNRS LTCI, F-75013 Paris, France
关键词
TOMOSYNTHESIS; UK;
D O I
10.1093/rpd/ncv069
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The radiation risk in mammography is traditionally evaluated using the average glandular dose. This quantity for the average breast has proven to be useful for population statistics and to compare exposure techniques and systems. However it is not indicating the individual radiation risk based on the individual glandular amount and distribution. Simulations of exposures were performed for six appropriate virtual phantoms with varying glandular amount and distribution. The individualised average glandular dose (iAGD), i.e. the individual glandular absorbed energy divided by the mass of the gland, and the glandular imparted energy (GIE), i.e. the glandular absorbed energy, were computed. Both quantities were evaluated for their capability to take into account the glandular amount and distribution. As expected, the results have demonstrated that iAGD reflects only the distribution, while GIE reflects both the glandular amount and distribution. Therefore GIE is a good candidate for individual radiation risk assessment.
引用
收藏
页码:342 / 345
页数:4
相关论文
共 50 条
  • [1] Method for the evaluation of a average glandular dose in mammography
    Okunade, AA
    [J]. MEDICAL PHYSICS, 2006, 33 (04) : 1153 - 1164
  • [2] New Way for Calculating the Average Glandular Dose in the Mammography
    Penchev, P.
    Schopphoven, S.
    Smirnov, A.
    Bock, K.
    Fiebich, M.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Exposure Parameters and Average Glandular Dose in a Digital Mammography System in Japan
    Nishide, Hiroko
    Ohta, Kouji
    Murata, Kaori
    Kodera, Yoshie
    Shimamoto, Kazuhiro
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (05) : 1030 - 1034
  • [4] NORMALIZED AVERAGE GLANDULAR DOSE IN MAGNIFICATION MAMMOGRAPHY
    LIU, B
    GOODSITT, M
    CHAN, HP
    [J]. RADIOLOGY, 1995, 197 (01) : 27 - 32
  • [5] Patient Specific Average Glandular Dose in Mammography
    Patel, V.
    Highnam, R.
    Tromans, C.
    Pizzutiello, R. J.
    Destounis, S.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [6] Parametrization of mammography normalized average glandular dose tables
    Sobol, WT
    Wu, XZ
    [J]. MEDICAL PHYSICS, 1997, 24 (04) : 547 - 554
  • [7] Average Glandular Dose in Digital Mammography and Breast Tomosynthesis
    Olgar, T.
    Kahn, T.
    Gosch, D.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2012, 184 (10): : 911 - 918
  • [8] Average glandular dose and phantom image quality in mammography
    Oliveira, M.
    Noguelra, M. S.
    Guedes, E.
    Andrade, M. C.
    Peixoto, J. E.
    Joana, G. S.
    Castro, J. G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 574 - 577
  • [9] Evaluation of Image Quality and Average Glandular Dose Using the Resolution Testing Phantom in Mammography
    Chao, Y. T.
    Chen, C. Y.
    Dong, S. L.
    [J]. 1ST GLOBAL CONFERENCE ON BIOMEDICAL ENGINEERING & 9TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, 2015, 47 : 144 - 146
  • [10] Effect of anode/filter combination on average glandular dose in mammography
    Biegala, Michal
    Jakubowska, Teresa
    Markowska, Karolina
    [J]. JOURNAL OF MEDICAL PHYSICS, 2015, 40 (01) : 45 - 51