Optimization of headspace solid-phase microextraction gas chromatography-atomic emission detection analysis of monomethylmercury

被引:14
|
作者
Geerdink, Rene Bernard [1 ]
Breidenbach, Rembert [1 ]
Epema, Onno Jacob [1 ]
机构
[1] RIZA, Natl Inst Inland Water Management & Waste Water T, NL-8200 AA Lelystad, Netherlands
关键词
monomethylmercury; MeHg; propylation; headspace; SPME; HS-SPME; cold fiber;
D O I
10.1016/j.chroma.2007.08.070
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optimum conditions for headspace solid-phase microextraction (HS-SPME) in the analysis of monomethylmercury (MeHg) have been determined. Sodium tetra(n-)propylborate (NaBPr4) is used as derivatization reagent to promote volatility. A simple aluminium bar was used to cool the SPME fiber to about 2 degrees C during the equilibration phase just before extraction. HS-SPME was performed using different fibers. The 100 Rm polydimethylsiloxane (PDMS) and 65 mu m polydimethylsiloxane-divinylbenzene (PDMS-DVB) fibers showed the best results. Although the extraction efficiency for MeHg derivative of the polydimethylsiloxane-Carboxen (PDMS-CAR) fiber is similar to the other fibers, desorption of MeHg derivative from a PDMS-CAR fiber is poor. Factors affecting the HS-SPME process such as adsorption and desorption times, ionic strength (salting-out) and extraction temperature have been evaluated and optimized thoroughly. The highest extraction efficiency for the PDMS fiber was obtained by extraction at a low temperature 2 degrees C immediately after equilibration at 30 degrees C. With the PDMS-DVB and PDMS-CAR fiber improvement of extraction efficiency at lower temperatures is negligible. Repeated extraction out of the same vial revealed that about 30% of MeHg derivative is extracted from the headspace with a PDMS fiber at 2 degrees C and about 70% with a PDMS-DVB fiber. Repeated extraction with two different fiber coatings showed that the PDMS-CAR fiber also extracts about 70% but that the desorption is incomplete. Attempts to improve the desorption failed due to degradation of the MeHg derivate at high injection temperatures. The limit of detection (3 sigma) was 16 pg/L MeHg. The relative standard deviation (n = 8) for 100 pg/L of MeHg was found to be 5%. Linearity of the HS-SPME-GC-atomic emission detection method was established over at least two orders of magnitude in the range 0-2000 pg/L. Recovery of a surface water sample spiked at 2 ng/L was 85%. The suitability of the procedure was demonstrated by analysis of a surface water sample that showed a concentration of 100 pg/L MeHg. The optimized method can be used with standard commercial equipment without further adaptations. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:7 / 12
页数:6
相关论文
共 50 条
  • [21] Studies on the aroma of cupuassu liquor by headspace solid-phase microextraction and gas chromatography
    de Oliveira, AM
    Pereira, NR
    Marsaioli, A
    Augusto, F
    JOURNAL OF CHROMATOGRAPHY A, 2004, 1025 (01) : 115 - 124
  • [22] Analysis of total propionic acid in feed using headspace solid-phase microextraction and gas chromatography
    Ibáñez, C
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1017 (1-2) : 161 - 166
  • [23] Enantiomeric analysis of linalool in teas using headspace solid-phase microextraction with chiral gas chromatography
    Yang, Ting
    Zhu, Yin
    Shao, Chen-Yang
    Zhang, Yue
    Shi, Jiang
    Lv, Hai-Peng
    Lin, Zhi
    INDUSTRIAL CROPS AND PRODUCTS, 2016, 83 : 17 - 23
  • [24] Application of Headspace Solid-Phase Microextraction and Gas Chromatography for the Analysis of Furfural in Crude Palm Oil
    Loi, Chia Chun
    Boo, Huey Chern
    Mohamed, Abdulkarim Sabo
    Ariffin, Abdul Azis
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2010, 87 (06) : 607 - 613
  • [25] Analysis of pesticides volatilised from plants and soil by headspace solid-phase microextraction and gas chromatography
    J. Castro
    R. A. Pérez
    C. Sánchez-Brunete
    J. L. Tadeo
    Chromatographia, 2001, 53 : S361 - S365
  • [26] Automated headspace solid-phase microextraction and capillary gas chromatography analysis of ethanol in postmortem specimens
    De Martinis, BS
    Martin, CCS
    FORENSIC SCIENCE INTERNATIONAL, 2002, 128 (03) : 115 - 119
  • [27] Determination of acrolein by headspace solid-phase microextraction gas chromatography and mass spectrometry
    Takamoto, S
    Sakura, N
    Yashiki, M
    Kojima, T
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 758 (01): : 123 - 128
  • [28] Analysis of pesticides volatilised from plants and soil by headspace solid-phase microextraction and gas chromatography
    Castro, J
    Pérez, RA
    Sánchez-Brunete, C
    Tadeo, JL
    CHROMATOGRAPHIA, 2001, 53 (Suppl 1) : S361 - S365
  • [29] Analysis of wine bouquet components using headspace solid-phase microextraction capillary gas chromatography
    Garcia, DDLC
    Reichenbaher, M
    Denzer, K
    Hurlbeck, C
    Bartzsch, C
    Feller, KH
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (07): : 373 - 377
  • [30] Determination of amphetamines in human urine by headspace solid-phase microextraction and gas chromatography
    Raikos, N
    Christopoulou, K
    Theodoridis, G
    Tsoukali, H
    Psaroulis, D
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (01): : 59 - 63