Automated headspace solid-phase microextraction and capillary gas chromatography analysis of ethanol in postmortem specimens

被引:36
|
作者
De Martinis, BS [1 ]
Martin, CCS [1 ]
机构
[1] Univ Sao Paulo, Ctr Legal Med, Fac Med Ribeirao Preto, Dept Pathol, BR-14051140 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
HS-SPME; ethanol; postmortem specimens;
D O I
10.1016/S0379-0738(02)00182-2
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Solid-phase microextraction (SPME) is a relatively new solventless sample preparation technique that allows simultaneous sampling, extraction, pre-concentration, and introduction of analytes from a sample matrix in a single procedure. This methodology has been used for the analysis of several drugs of forensic toxicology interest including volatile compounds. This paper describes a methodology for analysis of ethanol and other volatile compounds using automatic headspace solid-phase microextraction (HS-SPME) and capillary gas chromatography in postmortem specimens. The methodology was initially developed using standard solutions of acetaldehyde, acetone, methanol, and ethanol. Isobutanol was used as internal standard. Postmortem samples of blood, urine, and vitreous humor were obtained during medico-legal autopsies. To date, there are no published paper regarding alcohol analysis in vitreous humor specimens using HS-SPME and limited literature analyzing blood and urine samples. HS-SPME analysis showed that, under optimized conditions, ethanol and isobutanol (internal standard) were well-separated from other volatile compounds such as acetaldehyde, acetone, and methanol considered to be potential interferents in ethanol analysis. The calibration curves for each volatile compound demonstrated good linearity throughout the concentration range from 0.001 to 1.0 g/dl and the detection limit of ethanol in the studied specimens was approximately 0.0001 g/dl. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 50 条
  • [1] Determination of ethanol in human blood and urine by automated headspace solid-phase microextraction and capillary gas chromatography
    De Martinis, BS
    Ruzzene, MAM
    Martin, CCS
    ANALYTICA CHIMICA ACTA, 2004, 522 (02) : 163 - 168
  • [2] Analysis of cyanide in blood by headspace solid-phase microextraction (SPME) and capillary gas chromatography
    Takekawa, K
    Oya, M
    Kido, A
    Suzuki, O
    CHROMATOGRAPHIA, 1998, 47 (3-4) : 209 - 214
  • [3] Analysis of cyanide in blood by headspace solid-phase microextraction (SPME) and capillary gas chromatography
    K. Takekawa
    M. Oya
    A. Kido
    O. Suzuki
    Chromatographia, 1998, 47 : 209 - 214
  • [4] Analysis of wine bouquet components using headspace solid-phase microextraction capillary gas chromatography
    Garcia, DDLC
    Reichenbaher, M
    Denzer, K
    Hurlbeck, C
    Bartzsch, C
    Feller, KH
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (07): : 373 - 377
  • [5] Determination of ethanol in ionic liquids using headspace solid-phase microextraction–gas chromatography
    Fei Zhao
    Thehazhnan K. Ponnaiyan
    Christa M. Graham
    Constance A. Schall
    Sasidhar Varanasi
    Jared L. Anderson
    Analytical and Bioanalytical Chemistry, 2008, 392 : 1271 - 1275
  • [6] Static headspace, solid-phase microextraction and headspace solid-phase microextraction for BTEX determination in aqueous samples by gas chromatography
    Menéndez, JCF
    Sánchez, MLF
    Uría, JES
    Martínez, EF
    Sanz-Medel, A
    ANALYTICA CHIMICA ACTA, 2000, 415 (1-2) : 9 - 20
  • [7] Analysis of methanol or formic acid in body fluids by headspace solid-phase microextraction and capillary gas chromatography
    Lee, Xiao-Pen
    Kumazawa, Takeshi
    Kondo, Kei
    Sato, Keizo
    Suzuki, Osamu
    Journal of Chromatography B, 1999, 734 (01): : 155 - 162
  • [8] Analysis of methanol or formic acid in body fluids by headspace solid-phase microextraction and capillary gas chromatography
    Lee, XP
    Kumazawa, T
    Kondo, K
    Sato, K
    Suzuki, O
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 734 (01): : 155 - 162
  • [9] Automated headspace solid-phase microextraction versus headspace for the analysis of furan in foods by gas chromatography-mass spectrometry
    Altaki, M. S.
    Santos, F. J.
    Galceran, M. T.
    TALANTA, 2009, 78 (4-5) : 1315 - 1320
  • [10] Analysis of ethanol and methanol in human body fluids by headspace solid phase microextraction coupled with capillary gas chromatography
    Maleki, Ramin
    Farrhadi, Khalil
    Matin, Amir Abbas
    ANALYTICAL SCIENCES, 2006, 22 (09) : 1253 - 1255