Simplified protocol for whole-body Patlak parametric imaging with 18F-FDG PET/CT: Feasibility and error analysis

被引:19
|
作者
Yao, Shulin [1 ]
Feng, Tao [2 ]
Zhao, Yizhang [3 ]
Wu, Runze [3 ]
Wang, Ruimin [1 ]
Wu, Shina [1 ]
Li, Can [1 ]
Xu, Baixuan [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Nucl Med, Beijing 100853, Peoples R China
[2] UIH Amer Inc, Houston, TX 75054 USA
[3] Shanghai United Imaging Healthcare, Shanghai 201807, Peoples R China
关键词
input function; Patlak model; whole body parametric imaging;
D O I
10.1002/mp.14187
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Parametric imaging using the Patlak model has been shown to provide improved lesion detectability and specificity. The Patlak model requires both tissue time-activity curves (TACs) after equilibrium and knowledge of the input function from the start of injection. Therefore, the conventional dynamic scanning protocol typically starts from the radiotracer injection all the way to equilibrium. In this paper, we propose the use of hybrid population-based and model-based input function estimation and evaluate its use for whole-body Patlak analysis, in order to reduce the total scan time and simplify clinical Patlak parametric imaging protocols. Possible quantitative errors caused by the simplified scanning protocol were also analyzed both theoretically and with the use of clinical data. Materials and methods Clinical data from 24 patients referred for tumor staging were included in this study. The patients underwent a whole-body dynamic PET study, 20 min after FDG injection (0.13 mCi/kg). The proposed whole-body scanning protocol includes 6 passes with 4-5 bed positions, depending on the size of the patient, with 2 min for each bed position. An input function from the literature was selected as the shape of the population-based input function. The descending aorta from the corresponding CT image was segmented and applied on the reconstructed dynamic PET images to acquire an image-based input function, which was later fitted using an exponential model. Due to the late scan time, only the later portion of the input function was available, which was used to scale the population-based input function. The hybrid input function was used to derive the whole-body Patlak images. Assuming a given error in the population-based input function, its influence on the final Patlak images were also derived theoretically and verified using the clinical data sets. Finally, the image quality of the reconstructed Patlak slope image was evaluated by an experienced radiologist in four different aspects: image artifacts, image noise, lesion sharpness, and lesion detectability. Results It was found that errors in the population-based input function only affect the absolute scale of the Patlak slope image. The induced error is proportional to the percentage area-under-curve (AUC) error in the input function. These findings were also confirmed by numerical analysis. The predicted global scale was in good agreement with results from both image-based Patlak and direct Patlak approach. The fractions of the AUC from the early portion population-based input function were also found to be around 18% of the total AUC of the input function, further limiting the propagation of quantitation error from population-based input function to the final Patlak slope image. The reconstructed Patlak images were also found by the radiologist to provide excellent confidence in lesion detection tasks. Conclusions We have proposed a simplified whole-body scanning protocol that utilizes both population-based input function and model-based input function. The error from the population-based function was found to only affect the global scale and the overall quantitative impact can be predicted using our proposed formulas.
引用
收藏
页码:2160 / 2169
页数:10
相关论文
共 50 条
  • [31] Effective dose Estimation in Whole Body 18F-FDG PET/CT Imaging
    Karimipourfard, M.
    Sina, S.
    Shobeiry, M.
    Alavi, M. S.
    Faghihi, R.
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (18) : 1444 - 1449
  • [32] Comparison of the diagnostic value of whole-body DWI, 18F-FDG PET/CT and whole-body CT in metastatic breast cancer
    Gelezhe, Pavel
    Morozov, Sergey
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [33] Combined early dynamic 18F-FDG PET/CT and conventional whole-body 18F-FDG PET/CT provide one-stop imaging for detecting hepatocellular carcinoma
    Wang, Shao-bo
    Wu, Hu-bing
    Wang, Quan-shi
    Zhou, Wen-lan
    Tian, Ying
    Li, Hong-sheng
    Ji, Yun-hai
    Lv, Liang
    CLINICS AND RESEARCH IN HEPATOLOGY AND GASTROENTEROLOGY, 2015, 39 (03) : 324 - 330
  • [34] Clinical impact of fully automated multiparametric PET imaging using direct Patlak reconstruction: Evaluation of 100 dynamic whole-body 18F-FDG PET/CT scans
    Dias, A. H.
    Pedersen, M. F.
    Danielsen, H.
    Munk, O. L.
    Gormsen, L. C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S119 - S120
  • [35] Incidental pituitary uptake on whole-body 18F-FDG PET/CT: a multicentre study
    Jeong, Shin Young
    Lee, Sang-Woo
    Lee, Hui Joong
    Kang, Sungmin
    Seo, Ji-Hyoung
    Chun, Kyung Ah
    Cho, Ihn Ho
    Won, Kyung Sook
    Zeon, Seok Kil
    Ahn, Byeong-Cheol
    Lee, Jaetae
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (12) : 2334 - 2343
  • [36] A simulation study for estimating scatter fraction in whole-body 18F-FDG PET/CT
    Hosokawa S.
    Inoue K.
    Kano D.
    Shimizu F.
    Koyama K.
    Nakagami Y.
    Muramatsu Y.
    Fukushi M.
    Radiological Physics and Technology, 2017, 10 (2) : 204 - 212
  • [37] Incidental finding of horseshoe kidneys in whole-body 18F-FDG PET/CT evaluation
    Roldan-Valadez, E.
    Ortega-Lopez, N.
    Vega-Gonzalez, I.
    Valdivieso-Cardenas, G.
    Rumoroso-Garcia, A.
    Santillan, O. Morales
    REVISTA ESPANOLA DE MEDICINA NUCLEAR, 2007, 26 (02): : 105 - 106
  • [38] Optimized intravenous contrast administration for diagnostic whole-body 18F-FDG PET/CT
    Beyer, T
    Antoch, G
    Bockisch, A
    Stattaus, J
    JOURNAL OF NUCLEAR MEDICINE, 2005, 46 (03) : 429 - 435
  • [39] Incidental pituitary uptake on whole-body 18F-FDG PET/CT: a multicentre study
    Shin Young Jeong
    Sang-Woo Lee
    Hui Joong Lee
    Sungmin Kang
    Ji-Hyoung Seo
    Kyung Ah Chun
    Ihn Ho Cho
    Kyung Sook Won
    Seok Kil Zeon
    Byeong-Cheol Ahn
    Jaetae Lee
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 2334 - 2343
  • [40] Estimation of patient organ and whole-body doses in [18F-FDG] PET/CT scan
    Kessara, Aida
    Buyukcizmeci, Nihal
    Gedik, Gonca Kara
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (01) : 61 - 68