Dynamic measurements of total hepatic blood flow with Phase Contrast MRI

被引:32
|
作者
Yzet, Thierry [1 ]
Bouzerar, Roger [2 ]
Baledent, Olivier [2 ]
Renard, Cedric [1 ]
Lumbala, Didier Mbayo [1 ]
Nguyen-Khac, Eric [3 ]
Regimbeau, Jean-Marc [4 ]
Deramond, H. [1 ]
Meyer, Marc-Etienne [2 ]
机构
[1] Univ Hosp, Dept Radiol, F-80054 Amiens 1, France
[2] Jules Verne Univ Picardie, Univ Hosp, Dept Imaging & Biophys, F-80054 Amiens 1, France
[3] Univ Hosp, Mobile Unit Alcool, F-80054 Amiens 1, France
[4] Univ Hosp, Dept Visceral & Digest Gen Surg, F-80054 Amiens 1, France
关键词
PC-MRI; Hepatic hemodynamics; Hepatic artery; Portal vein; Total hepatic flow; MAGNETIC-RESONANCE; PORTAL-HYPERTENSION; CONTINUOUS INFUSION; INDOCYANINE GREEN; ECHO-DOPPLER; VENOUS FLOW; VOLUNTEERS; ULTRASOUND; ACCURACY; VOLUME;
D O I
10.1016/j.ejrad.2008.09.032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background/Aims: To measure total hepatic blood flow including portal and proper hepatic artery flows as well as the temporal evolution of the vessel's section during a cardiac cycle. Methods: Twenty healthy subjects, with a mean age of 26 years, were explored. Magnetic resonance imaging blood flow measurements were carried out in the portal vein and the proper hepatic artery. MR studies were performed using a 1.5T imager (General Electric Medical Systems). Gradient-echo 2D Fast Cine Phase Contrast sequences were used with both cardiac and respiratory gatings. Data analysis was performed using a semi-automatic software built in our laboratory. Results: The total hepatic flow rate measured was 1.35 +/- 0.18 L/min or 19.7 +/- 4.6 mL/(min kg). The proper hepatic artery provided 19.1% of the total hepatic blood flow entering the liver. Those measurements were in agreement with earlier studies using direct measurements. Mean and maximum velocities were also assessed and a discrepancy between our values and the literature's Doppler data was found. Measurements of the portal vein area have shown a mean variation, defined as a "pulsatility" index of 18% over a cardiac cycle. Conclusions: We report here proper hepatic artery blood flow rate measurements using MRI. Associated with portal flow measurements, we have shown the feasibility of total hepatic flowmetry using a non-invasive and harmless technique. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:119 / 124
页数:6
相关论文
共 50 条
  • [1] Quantitative Cerebral Blood Flow in Dynamic Susceptibility Contrast MRI Using Total Cerebral Flow from Phase Contrast Magnetic Resonance Angiography
    Bonekamp, David
    Degaonkar, Mahaveer
    Barker, Peter B.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 57 - 66
  • [2] Application of linear optimization techniques to MRI phase contrast blood flow measurements
    Morgan, VL
    Price, RR
    Lorenz, CH
    MAGNETIC RESONANCE IMAGING, 1996, 14 (09) : 1043 - 1051
  • [3] Hepatic Vascular Flow Measurements by Phase Contrast MRI and Doppler Echography: A Comparative and Reproducibility Study
    Yzet, Thierry
    Bouzerar, Roger
    Allart, Jean-Dominique
    Demuynck, Fabien
    Legallais, Cecile
    Robert, Brice
    Deramond, Herve
    Meyer, Marc-Etienne
    Baledent, Olivier
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 579 - 588
  • [4] Phase-contrast MRI analysis of cerebral blood and CSF flow dynamic interactions
    Kimi Piedad Owashi
    Pan Liu
    Serge Metanbou
    Cyrille Capel
    Olivier Balédent
    Fluids and Barriers of the CNS, 21 (1)
  • [5] Mean cerebral blood flow measurements using phase contrast MRI in the first year of life
    Varela, Marta
    Groves, Alan M.
    Arichi, Tomoki
    Hajnal, Joseph V.
    NMR IN BIOMEDICINE, 2012, 25 (09) : 1063 - 1072
  • [6] Reproducibility of total cerebral blood flow measurements using phase contrast magnetic resonance imaging
    Spilt, A
    Box, FMA
    van der Geest, RJ
    Reiber, JHC
    Kunz, P
    Kamper, AM
    Blauw, GJ
    van Buchem, MA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 16 (01) : 1 - 5
  • [7] Automated Quantification of Total Cerebral Blood Flow from Phase-Contrast MRI and Deep Learning
    Kim, Jinwon
    Lee, Hyebin
    Oh, Sung Suk
    Jang, Jinhee
    Lee, Hyunyeol
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024, 37 (02): : 563 - 574
  • [8] Visualization of Through-Plane Blood Flow Measurements Obtained from Phase-Contrast MRI
    Per Thunberg
    Anders Kähäri
    Journal of Digital Imaging, 2011, 24 : 470 - 477
  • [9] Visualization of Through-Plane Blood Flow Measurements Obtained from Phase-Contrast MRI
    Thunberg, Per
    Kahari, Anders
    JOURNAL OF DIGITAL IMAGING, 2011, 24 (03) : 470 - 477
  • [10] Contrast Agent Influences MRI Phase-Contrast Flow Measurements in Small Vessels
    Lagerstrand, Kerstin M.
    Vikhoff-Baaz, Barbro
    Starck, Goeran
    Forssell-Aronsson, Eva
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (01) : 42 - 46