Performance analysis of a ductless personalized ventilation combined with radiant floor cooling system and displacement ventilation

被引:40
|
作者
Liu, Jiying [1 ,2 ]
Dalgo, Daniel Alejandro [2 ]
Zhu, Shengwei [1 ]
Li, Hui [3 ]
Zhang, Linhua [3 ]
Srebric, Jelena [2 ]
机构
[1] Shandong Jianzhu Univ, Sch Thermal Engn, Jinan 250101, Shandong, Peoples R China
[2] Univ Maryland, Dept Mech Engn, College Pk, MD 20742 USA
[3] Shandong Jianzhu Univ, Minist Educ, Key Lab Renewable Energy Utilizat Technol Bldg, Jinan 250101, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
computational fluid dynamics (CFD); ductless personalized ventilation (DPV); displacement ventilation (DV); radiant floor cooling system (RFCS); INDOOR THERMAL COMFORT; AIR-CONDITIONING SYSTEM; ENERGY PERFORMANCE; CFD; CONJUNCTION; ROOMS; TEMPERATURE; EFFICIENCY; QUALITY; SAVINGS;
D O I
10.1007/s12273-019-0521-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
This study conducted the numerical simulation to evaluate the performance of a ductless personalized ventilation (DPV) combined with radiant floor cooling system (RFCS) and displacement ventilation (DV) system. In the non-DPV cases, DV supplies air at temperature of 16 degrees C and 20 degrees C, respectively with a flow rate of 2.4 ACH. In the cases with DPV, DPV supplies personalized air, which is drawn at the height of 0.1 m or 0.2 m above the floor, to the face of a seated occupant at flow rates of 3 L/s, 5 L/s and 7 L/s, respectively. The horizontal distance of 0.3 m is designed between DPV air supply opening and occupant face at the height of 1.2m. For all the cases, the floor cooling temperature is set to 20 degrees C. The vertical air temperature difference at 1.1 m and 0.1 m (Delta T1.1-0.1), the contaminant removal effectiveness (epsilon) and the draft rate at the occupant face (DRface) are mainly used as evaluation indices to quantify the ventilation effectiveness and thermal comfort effect. According to the results, DPV remarkably decreases Delta T1.1-0.1 with a maximum reduction of 1.79 degrees C compared to non-DPV case. DPV significantly influences the temperature adjacent to the face at the breathing zone, with a maximum reduction of 4.44 degrees C from non-DPV case to DPV case. DPV cases also effectively improve epsilon at breathing region compared to the non-DPV case. The DRface ranges from 9.01% to 21.33% when different flow rates of DPV are used. In summary, the case using DPV flow rate of 5 L/s and at intake height of 0.1 m presented relatively better ventilation effectiveness and thermal comfort environment around the occupant.
引用
收藏
页码:905 / 919
页数:15
相关论文
共 50 条
  • [21] Performance assessment of a ductless personalized ventilation system using a validated CFD model
    Alsaad, Hayder
    Voelker, Conrad
    JOURNAL OF BUILDING PERFORMANCE SIMULATION, 2018, 11 (06) : 689 - 704
  • [22] Performance of personalized ventilation in conjunction with mixing and displacement ventilation
    Cermak, R
    Melikov, AK
    Forejt, L
    Kovar, O
    HVAC&R RESEARCH, 2006, 12 (02): : 295 - 311
  • [23] Experimental Study on Performance Comparison Between Heavy and Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation Air Conditioning System
    Zhang, Dongliang
    Cai, Ning
    Rui, Yingxiang
    Tang, Hu
    Liu, Minghui
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 475 - 483
  • [24] Simulation study on the thermal environment in an office with radiant cooling and displacement ventilation system
    Yang, Yujia
    Wang, Yu
    Yuan, Xiaolei
    Zhu, Yutong
    Zhang, Dandan
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3140 - 3147
  • [25] Developing a collaborative control strategy of a combined radiant floor cooling and ventilation system: A PMV-based model
    Ren, Jing
    Liu, Jiying
    Zhou, Shiyu
    Kim, Moon Keun
    Miao, Jikui
    JOURNAL OF BUILDING ENGINEERING, 2022, 54
  • [26] A simplified combined displacement and personalized ventilation model
    Alain, Makhoul
    Kamel, Ghali
    Nesreen, Ghaddar
    HVAC&R RESEARCH, 2012, 18 (04): : 737 - 749
  • [27] An Experimental Study on Operating Characteristic of Radiant Floor Cooling Integrated with Underfloor Ventilation System
    Cai, Ning
    Zhang, Dongliang
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2021, 39 (04) : 1207 - 1212
  • [28] Numerical Simulation on Indoor Thermal Environment of Radiant Flooring Cooling System with Displacement Ventilation
    Cai, Wei
    Lv, Wen
    Zhu, Lexian
    Yang, Pengfeng
    BUILDING MATERIALS AND STRUCTURAL ENGINEERING II, 2013, 743 : 90 - +
  • [29] Experimental study on control strategies of radiant floor cooling system with direct-ground cooling source and displacement ventilation system: A case study in an office building
    Ren, Jing
    Liu, Jiying
    Zhou, Shiyu
    Kim, Moon Keun
    Song, Shoujie
    ENERGY, 2022, 239
  • [30] Experimental study on control strategies of radiant floor cooling system with direct-ground cooling source and displacement ventilation system: A case study in an office building
    Ren, Jing
    Liu, Jiying
    Zhou, Shiyu
    Kim, Moon Keun
    Song, Shoujie
    Energy, 2022, 239