Ionization Mechanism of Positive-Ion Direct Analysis in Real Time: A Transient Microenvironment Concept

被引:112
|
作者
Song, Liguo [1 ]
Gibson, Stephen C. [1 ]
Bhandari, Deepak [1 ]
Cook, Kelsey D. [1 ]
Bartmess, John E. [1 ]
机构
[1] Univ Tennessee, Dept Chem, Mass Spectrometry Ctr, Knoxville, TN 37996 USA
关键词
DESORPTION ELECTROSPRAY-IONIZATION; ATMOSPHERIC-PRESSURE PHOTOIONIZATION; MASS-SPECTROMETRIC TECHNIQUE; HAIRY ROOT CULTURE; OF-FLIGHT; AMBIENT CONDITIONS; MAXIMIZE THROUGHPUT; CYCLOTRON RESONANCE; OPEN-AIR; DART;
D O I
10.1021/ac901122b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A transient microenvironment mechanism (TMEM) is proposed to address matrix effects for direct analysis in real time (DART). When the DART gas stream is in contact with the sample, a transient microenvironment (TME), which can shield analytes from direct ionization, may be generated through the desorption of the matrix containing the analyte. The DART gas stream can directly ionize the matrix molecules, but the analytes will be ionized primarily through gas-phase ion/molecule reactions with the matrix ions. Experimental results showed that as little as 10 nL of liquid or 10 mu g of solid was able to generate an efficient TME. Generated TMEs were able to control the ionization of an analyte below an analyte-to-matrix ratio that was dependent on the DART temperature and the boiling points of the analyte and matrix. TMEs generated by common solvents were studied in detail. The ionization of both polar and nonpolar compounds, present in a solvent or another analyte below a ratio of 1:100, were found to be mainly controlled by the generated TMEs at a DART temperature of 300 degrees C.
引用
收藏
页码:10080 / 10088
页数:9
相关论文
共 50 条
  • [31] POSITIVE-ION AND ELECTRON-CAPTURE NEGATIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY OF POLYCHLOROPHENOXYANISOLES
    CAMPBELL, JAB
    GRIFFIN, DA
    DEINZER, ML
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1984, 187 (APR): : 34 - ANYL
  • [32] EFFECTS OF ANIONS ON THE POSITIVE-ION ELECTROSPRAY-IONIZATION MASS-SPECTRA OF PEPTIDES AND PROTEINS
    MIRZA, UA
    CHAIT, BT
    ANALYTICAL CHEMISTRY, 1994, 66 (18) : 2898 - 2904
  • [33] POSITIVE-ION PAIR PRODUCTION BY ELECTRON-IMPACT DISSOCIATIVE IONIZATION OF CF4
    BRUCE, MR
    MA, C
    BONHAM, RA
    CHEMICAL PHYSICS LETTERS, 1992, 190 (3-4) : 285 - 290
  • [34] NEGATIVE AND POSITIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY OF DIOXIMES AND THEIR NICKEL-COMPLEXES
    CHARALAMBOUS, J
    MORGAN, JS
    OPERTI, L
    VAGLIO, GA
    VOLPE, P
    INORGANICA CHIMICA ACTA, 1988, 144 (02) : 201 - 203
  • [35] Acetonitrile as an effective reactant species for positive-ion chemical ionization of hydrocarbons by ion-trap mass spectrometry
    Moneti, G
    Pieraccini, G
    Dani, FR
    Catinella, S
    Traldi, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (02) : 167 - 170
  • [36] NITROUS-OXIDE AS REAGENT GAS FOR POSITIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY
    POLLEY, CW
    MUNSON, B
    ANALYTICAL CHEMISTRY, 1983, 55 (04) : 754 - 757
  • [37] DIRECT OBSERVATION OF A HIGHLY MOBILE POSITIVE-ION IN NANOSECOND PULSE IRRADIATED LIQUID CYCLOHEXANE
    DEHAAS, MP
    WARMAN, JM
    INFELTA, PP
    HUMMEL, A
    CHEMICAL PHYSICS LETTERS, 1975, 31 (02) : 382 - 386
  • [38] ELECTRON-CAPTURE NEGATIVE-ION AND POSITIVE-ION CHEMICAL IONIZATION MASS-SPECTROMETRY OF POLYCHLORINATED PHENOXYANISOLES
    CAMPBELL, JAB
    GRIFFIN, DA
    DEINZER, ML
    ORGANIC MASS SPECTROMETRY, 1985, 20 (02): : 122 - 133
  • [39] Ionization characteristics of amino acids in direct analysis in real time mass spectrometry
    Sekimoto, Kanako
    Sakakura, Motoshi
    Kawamukai, Takatomo
    Hike, Hiroshi
    Shiota, Teruhisa
    Usui, Fumihiko
    Bando, Yasuhiko
    Takayama, Mitsuo
    ANALYST, 2014, 139 (10) : 2589 - 2599
  • [40] Studies on the positive-ion mass spectra from atmospheric pressure chemical ionization of gases and solvents used in liquid chromatography and direct liquid injection
    Kolakowski, BA
    Grossert, JS
    Ramaley, L
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2004, 15 (03) : 311 - 324