Ionization Mechanism of Positive-Ion Direct Analysis in Real Time: A Transient Microenvironment Concept

被引:112
|
作者
Song, Liguo [1 ]
Gibson, Stephen C. [1 ]
Bhandari, Deepak [1 ]
Cook, Kelsey D. [1 ]
Bartmess, John E. [1 ]
机构
[1] Univ Tennessee, Dept Chem, Mass Spectrometry Ctr, Knoxville, TN 37996 USA
关键词
DESORPTION ELECTROSPRAY-IONIZATION; ATMOSPHERIC-PRESSURE PHOTOIONIZATION; MASS-SPECTROMETRIC TECHNIQUE; HAIRY ROOT CULTURE; OF-FLIGHT; AMBIENT CONDITIONS; MAXIMIZE THROUGHPUT; CYCLOTRON RESONANCE; OPEN-AIR; DART;
D O I
10.1021/ac901122b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A transient microenvironment mechanism (TMEM) is proposed to address matrix effects for direct analysis in real time (DART). When the DART gas stream is in contact with the sample, a transient microenvironment (TME), which can shield analytes from direct ionization, may be generated through the desorption of the matrix containing the analyte. The DART gas stream can directly ionize the matrix molecules, but the analytes will be ionized primarily through gas-phase ion/molecule reactions with the matrix ions. Experimental results showed that as little as 10 nL of liquid or 10 mu g of solid was able to generate an efficient TME. Generated TMEs were able to control the ionization of an analyte below an analyte-to-matrix ratio that was dependent on the DART temperature and the boiling points of the analyte and matrix. TMEs generated by common solvents were studied in detail. The ionization of both polar and nonpolar compounds, present in a solvent or another analyte below a ratio of 1:100, were found to be mainly controlled by the generated TMEs at a DART temperature of 300 degrees C.
引用
收藏
页码:10080 / 10088
页数:9
相关论文
共 50 条
  • [1] Ionization Mechanism of Positive-Ion Nitrogen Direct Analysis in Real Time
    Song, Liguo
    Chuah, Wei Chean
    Lu, Xinyi
    Remsen, Edward
    Bartmess, John E.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2018, 29 (04) : 640 - 650
  • [2] Ionization characteristics of various amino acids in positive-ion helium direct analysis in real-time quadrupole time-of-flight mass spectrometry
    Liu, Jianing
    Yu, Peng
    Wu, Tong
    Ma, Delai
    Sun, Yankun
    Zhang, Xinran
    Yang, Hongmei
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2024, 38 (19)
  • [3] Aperture Size Influences Oxidation in Positive-Ion Nitrogen Direct Analysis in Real Time Mass Spectrometry
    Cody, Robert B.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2022, 33 (07) : 1329 - 1334
  • [4] High-mass capabilities of positive-ion and negative-ion direct analysis in real time mass spectrometry
    Gross, Juergen H.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2016, 22 (01) : 43 - 48
  • [5] Study of Mechanism of Ionization Assisted by Methylation in Direct Analysis in Real Time Ion Source
    Yu Qing
    Yu Binbin
    Yue Hao
    Jiao Lili
    Liu Shuying
    ACTA CHIMICA SINICA, 2012, 70 (15) : 1650 - 1654
  • [6] Saccharose cluster ions as mass calibrants in positive-ion direct analysis in real time-mass spectrometry
    Gross, Juergen H.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2020, 26 (05) : 324 - 331
  • [7] Positive-ion analysis of boropeptides by chemical ionization and liquid secondary ionization mass spectrometry
    Haas, MJ
    Blom, KF
    Schwarz, CH
    ANALYTICAL CHEMISTRY, 1999, 71 (08) : 1574 - 1578
  • [8] A time-resolved study of ionization, electron attachment and positive-ion drift in methane
    de Urquijo, J
    Arriaga, CA
    Cisneros, C
    Alvarez, I
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (01) : 41 - 45
  • [9] Efficiency of ionization in hydrogen by positive-ion impact at 7000 volts
    Gurney, RW
    PHYSICAL REVIEW, 1928, 32 (05): : 0795 - 0798
  • [10] Ionization Mechanism of Negative Ion-Direct Analysis in Real Time: A Comparative Study with Negative Ion-Atmospheric Pressure Photoionization
    Song, Liguo
    Dykstra, Andrew B.
    Yao, Huifang
    Bartmess, John E.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (01) : 42 - 50