Measurements and Evaluation of the Image Noise Power Spectrum for Computed Radiography

被引:0
|
作者
Park, Hye-Suk [1 ]
Kim, Hee-Joung [1 ]
Cho, Hyo-Min [1 ]
Jung, Jiyoung [1 ]
Lee, Chang-Lae [1 ]
机构
[1] Yonsei Univ, Inst Hlth Sci, Dept Radiol Sci, Wonju 220710, GangwonDo, South Korea
关键词
QUALITY CHARACTERIZATION; DETECTOR PERFORMANCE; SYSTEMS;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Digital radiography has gained popularity in many areas of clinical practice. With this transition has come interest in advancing methodologies for image quality characterization. Modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) are widely accepted measurements of system performance. The NPS is one of the most common metrics describing the noise amplitude and texture observed in images obtained with a uniform field of radiation. Yet the comparability of the results is compromised by the different measurement parameters and evaluation methods. Because of the variety of methods used, it is difficult to compare previously published NPS results using different methodologies. In this paper, the following factors were evaluated for their effect on the measured NPS using the international electro-technical commission (IEC 62220-1)-defined RQA5 (additional Filter 21 mmAl, 72 kVp) radiographic techniques: impact of different exposure levels or radiation qualities, impact of the region of interest (ROI) and sub-ROI size, directional dependence, impact of overlapping versus non-overlapping sub-ROI size, and positional dependence for establishing the ROI. The results of Agfa CR (computed radiography, Toshiba, E8239X generator with Agfa CR 25 Corp.) showed that the shape of the normalized noise power spectrum (NNPS) curves decreased gradually as spatial frequency was increased. The various processing factors used in this study were found to have relatively little influence on the measured NPS. Our results suggest that the various processing factors could be used for computing the NPS with confidence. The results of this study could be used as a baseline to standardize the NIPS processing by measuring NPS for different methodologies.
引用
收藏
页码:3652 / 3657
页数:6
相关论文
共 50 条
  • [1] Comparison of the Image Noise Power Spectra for Computed Radiography
    Park, Hye-Suk
    Cho, Hyo-Min
    Jung, Jiyoung
    Lee, Chang-Lae
    Kim, Hee-Joung
    [J]. JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 54 (01) : 236 - 243
  • [2] Intrinsic Noise Power Spectrum for the Electronic Noise in Radiography Image Detectors
    Kim, Dong Sik
    Kim, Eun
    Shin, Choul Woo
    [J]. MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [3] Empirical Noise Power Spectrum Based on the Image Subtraction in Radiography Imaging
    Kim, Dung Sik
    Lee, Eunae
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [4] High-precision noise power spectrum measurements in digital radiography imaging
    Kim, Dong Sik
    [J]. MEDICAL PHYSICS, 2018, 45 (12) : 5461 - 5471
  • [5] MEASUREMENTS OF RESOLUTION AND IMAGE NOISE FOR DENTAL RADIOGRAPHY
    SCHOENFELD, CM
    MOORE, BK
    LIN, PJ
    [J]. JOURNAL OF DENTAL RESEARCH, 1976, 55 : B247 - B247
  • [6] Noise power spectrum of the fixed pattern noise in digital radiography detectors
    Kim, Dong Sik
    Kim, Eun
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 2765 - 2773
  • [7] Image quality evaluation of a desktop computed radiography system
    Fetterly, KA
    Hangiandreou, NJ
    [J]. MEDICAL PHYSICS, 2000, 27 (12) : 2669 - 2679
  • [8] Precision Analysis of the Noise Power Spectrum Estimate in Radiography Imaging
    Lee, Eunae
    Kim, Dong Sik
    [J]. MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [9] Accuracy and Precision in Estimating Noise Power Spectrum in Radiography Imaging
    Lee, Eunae
    Kim, Dong Sik
    [J]. INTERNATIONAL WORKSHOP ON ADVANCED IMAGE TECHNOLOGY (IWAIT) 2019, 2019, 11049
  • [10] Evaluation of an edge method for computed radiography and an electronic portal imaging device in radiotherapy: Image quality measurements
    Soon-Yong Son
    Bo-Young Choe
    Jeong-Woo Lee
    Jung-Min Kim
    Hoi-Woun Jeong
    Ham-Gyum Kim
    Wha-Sun Kim
    Kwang-Yeul Lyu
    Jung-Whan Min
    Ki-Won Kim