High-precision noise power spectrum measurements in digital radiography imaging

被引:22
|
作者
Kim, Dong Sik [1 ]
机构
[1] Hankuk Univ Foreign Studies, Dept Elect Engn, Gyeonggi Do 17035, South Korea
基金
新加坡国家研究基金会;
关键词
cross periodogram; estimate precision; noise power spectrum; radial averaging; radiography imaging;
D O I
10.1002/mp.13218
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Accurately and precisely estimating the noise power spectrum (NPS) is important for characterizing the performance of a radiography detector and helpful for improving the performance when developing radiography detectors. In order to produce an accurate estimate, the frequency resolution should be sufficiently high, and for a precise estimate, the sample size for the sample mean should also be large enough. However, there is a trade-off between the frequency resolution and the sample size if the available samples are limited. To improve the precision of the estimate, a radial averaging technique is employed in the IEC standard without sacrificing the frequency resolution or the estimate accuracy. In the radial averaging technique, directional NPS curves of a range are averaged from the two-dimensional NPS, and thus, directional error and poor precision problems occur, especially at low frequencies. This problem also leads to uncertainties in calculating the detective quantum efficiency (DQE). Therefore, the purpose of this study is to develop algorithms that can improve the precisions in estimating NPS to replace the radial averaging technique or to add additional precision. Methods The horizontal or vertical NPS curve can be estimated using the sample mean of the summation of directional cross periodograms with various distances from the two-dimensional NPS. In practical x-ray imaging, the amplitude response of the cross periodograms decreases rapidly as the distance increases. Hence, a partial summation of the cross periodograms can provide an accurate estimate of the NPS. This partial summation can increase the sample size and thus improve the estimate precision for the entire frequency range without causing directional errors. This paper proposes two estimate algorithms under the notion of the partial use of cross periodograms. Results In order to evaluate the precisions from the proposed algorithms, a relative precision, which is defined as the standard deviation of the estimate divided by its average, was employed. The relative precisions were calculated using 100 x-ray images acquired from a general radiography detector. For the detector, we were able to achieve a better precision compared to using the radial averaging technique. For an image of 900 x 900 pixels and the region of interest size 256 in a direction with a half overlap, the conventional approach of the IEC standard yielded an average relative precision of 6.96% with the worst precision of 36.1% at the zero frequency. However, the proposed algorithms could yield an average relative precision of 4.14% with the zero-frequency precision of 5.79%. Conclusions Without using the radial averaging technique, the proposed algorithms in this paper could improve the estimate precisions for the entire frequency range under the notion of a partial summation of the cross periodograms. Especially for low frequencies including the zero frequency, the proposed algorithms could achieve a high-precision to estimate the NPS.
引用
收藏
页码:5461 / 5471
页数:11
相关论文
共 50 条
  • [1] Precision Analysis of the Noise Power Spectrum Estimate in Radiography Imaging
    Lee, Eunae
    Kim, Dong Sik
    [J]. MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [2] Accuracy and Precision in Estimating Noise Power Spectrum in Radiography Imaging
    Lee, Eunae
    Kim, Dong Sik
    [J]. INTERNATIONAL WORKSHOP ON ADVANCED IMAGE TECHNOLOGY (IWAIT) 2019, 2019, 11049
  • [4] Noise power spectrum of the fixed pattern noise in digital radiography detectors
    Kim, Dong Sik
    Kim, Eun
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 2765 - 2773
  • [5] Measurements and Evaluation of the Image Noise Power Spectrum for Computed Radiography
    Park, Hye-Suk
    Kim, Hee-Joung
    Cho, Hyo-Min
    Jung, Jiyoung
    Lee, Chang-Lae
    [J]. 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3652 - 3657
  • [6] Measurements of the noise power spectrum for digital x-ray imaging devices
    Kim, Dong Sik
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (03):
  • [7] A HIGH-PRECISION DIGITAL METHOD OF FM SIGNAL PARAMETER MEASUREMENTS
    PISKORGE, VV
    FALKOVICH, IS
    [J]. IZVESTIYA VYSSHIKH UCHEBNYKH ZAVEDENII RADIOELEKTRONIKA, 1982, 25 (08): : 69 - 73
  • [8] Increasing the precision in the estimates of noise power spectrum in digital x-ray imaging systems
    Gonzalez-Lopez, Antonio
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (23):
  • [9] Empirical Noise Power Spectrum Based on the Image Subtraction in Radiography Imaging
    Kim, Dung Sik
    Lee, Eunae
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [10] Design of High-precision Power Supply Digital Control System
    Ju, Peng
    Gao, Ge
    Wang, Linsen
    [J]. IECON 2017 - 43RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2017, : 1066 - 1071