Accuracy of an infrared tympanic thermometer

被引:35
|
作者
Amoateng-Adjepong, Y [1 ]
Del Mundo, J [1 ]
Manthous, CA [1 ]
机构
[1] Yale Univ, Sch Med, Bridgeport Hosp, Dept Pulm & Crit Care, New Haven, CT USA
关键词
fever; infection; nursing; temperature; thermometer; thermometry;
D O I
10.1378/chest.115.4.1002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The use of infrared thermometry to measure temperatures in hospitalized patients is increasing. Although infrared thermometers have been proven to be accurate when they are used by well-trained personnel, no previous studies have examine their accuracy during routine hospital use, Objective: To determine the accuracy and observer variability of temperatures measured with an infrared tympanic thermometer (TT). Design: Prospective, observational study. Setting: ICUs of a 300-bed teaching community hospital. Patients: Fifty-one critically ill patients. Measurements: The mean of three tympanic temperatures measured with the infrared TT (tempTTs) was compared to temperatures simultaneously measured with the thermistor of right heart catheters and rectal mercury thermometers for the following three groups of observers who had been certified in the use of the infrared TT: a single critical care nurse (CCN)/educator (Ed); CCNs, and floor nurses (FNs)/clinical care practitioners (CCPs). Results: Two rounds of measurements were given to 51 patients by 153 observers. Temperatures of tbe pulmonary artery (PA) measured with the thermistor of light heart: catheters (tempPAs) ranged from 96.5 to 102.6 degrees F, with a mean ( +/- SD) of 99.3 +/- 1.1 degrees F. The intraobserver variabilities (correlation coefficients) of the tempTTs ranged from 0.90 for those measured by FNs/CCPs, to 0.92 for those measured by CCNs, to 0.98 for those measured by the CCN/Ed. Accuracy, arbitrarily defined as within a deviation of +/- 0.5 degrees F of the tempPA, was 100% for the rectal mercury thermometer and 98.0% for the infrared TT when used by the CCN/Ed. The accuracy of die infrared TT was 80% when measured by CCNs and 61% when measured by FNs/CCPs. Differences between tempPAs and tempTTs measured by the CCN/Ed ranged front 0 to 0.7 degrees F, with a mean of 0.2 degrees F. Similarly, differences between tempPAs and tempTTs measured by CCNs ranged from 0 to 2.4 degrees F, with a mean difference of 0.3 degrees F. However, differences between tempPAs and tempTTs measured by FNs/CCPs ranged from 0 to 3.0 degrees F, with a mean of 0.6 degrees F (greater differences than those obtained by the CCNs; p < 0.01). The accuracy of rectal mercury thermometry tvas 100%. If a temperature greater than or equal to 101.0 degrees F had been considered as the threshold at which a fever is present, and if the mean of three measurements had been used to designate temperature, workups that were either inappropriately performed or omitted would have resulted from 2% of tempTTs measured by the CCN/Ed, 1% of those measured by CCNs, and 4% of those measured by FNs/CCPs. Conclusion: When used properly, both tympanic and rectal thermometry are very accurate. However, the infrared TT produced measurements that were both less accurate and less reproducible when used by nurses who routinely used it in clinical practice.
引用
收藏
页码:1002 / 1005
页数:4
相关论文
共 50 条
  • [21] EVALUATION OF A TYMPANIC THERMOMETER IN CHILDREN
    BROGAN, P
    CHILDS, C
    PHILLIPS, BM
    MOULTON, C
    [J]. LANCET, 1993, 342 (8883): : 1364 - 1365
  • [22] The accuracy and precision of tympanic temperature with a new optical fiber thermometer during cardiac surgery
    Matsukawa, T
    Kawamura, A
    Ozaki, M
    Kumazawa, T
    [J]. ANESTHESIOLOGY, 2000, 93 (3A) : U146 - U146
  • [23] Comparison of body temperatures of goats, horses, and sheep measured with a tympanic infrared thermometer, an implantable microchip transponder, and a rectal thermometer
    Goodwin, SD
    [J]. CONTEMPORARY TOPICS IN LABORATORY ANIMAL SCIENCE, 1998, 37 (03): : 51 - 55
  • [24] The tympanic thermometer in pediatrics as an alternative to the mercury-in-glass thermometer
    Victoria Vertedor-Hurtado, Maria
    Padin-Lopez, Susana
    Jose Carreira-Pastor, Maria
    Maria Lopez-Martinez, Julia
    [J]. ENFERMERIA CLINICA, 2009, 19 (03): : 115 - 120
  • [25] The usefulness of an earphone-type infrared tympanic thermometer for Intraoperative core temperature monitoring
    Kiya, Tomohiro
    Yamakage, Michiaki
    Hayase, Tomo
    Satoh, Jun-Ichi
    Namiki, Akiyoshi
    [J]. ANESTHESIA AND ANALGESIA, 2007, 105 (06): : 1688 - 1692
  • [26] REEVALUATION OF THE TYMPANIC THERMOMETER IN THE EMERGENCY DEPARTMENT
    STEWART, JV
    WEBSTER, D
    [J]. ANNALS OF EMERGENCY MEDICINE, 1992, 21 (02) : 158 - 161
  • [27] ASSESSMENT OF HYPOTHERMIA WITH A NEW TYMPANIC THERMOMETER
    WALPOTH, BH
    GALDIKAS, J
    LEUPI, F
    MUEHLEMANN, W
    SCHLAEPFER, P
    ALTHAUS, U
    [J]. JOURNAL OF CLINICAL MONITORING, 1994, 10 (02): : 91 - 96
  • [28] Key Factors on the Accuracy of Measurement Temperature by Using Infrared Thermometer
    Zeng, Ling
    Li, Xunping
    He, Xiaoqi
    Li, Guoyuan
    Wang, Zhangchao
    Bao, Hengwei
    [J]. PROCEEDINGS OF 2014 10TH INTERNATIONAL CONFERENCE ON RELIABILITY, MAINTAINABILITY AND SAFETY (ICRMS), VOLS I AND II, 2014, : 804 - 807
  • [29] Infrared tympanic thermometer can accurately measure the body temperature in children in an emergency room setting
    Kocoglu, H
    Goksu, S
    Isik, M
    Akturk, Z
    Bayazit, YA
    [J]. INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2002, 65 (01) : 39 - 43
  • [30] Clinical evaluation of a new infrared tympanic thermometer "TH 700" by Rowenta or "Thermo Sense" by CALOR
    Brinnel, H
    De Wasseige, P
    Delhomme, G
    Dittmar, A
    Jourdain, S
    [J]. 1ST ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2000, : 255 - 258