The tympanic thermometer in pediatrics as an alternative to the mercury-in-glass thermometer

被引:4
|
作者
Victoria Vertedor-Hurtado, Maria [1 ]
Padin-Lopez, Susana [1 ]
Jose Carreira-Pastor, Maria [1 ]
Maria Lopez-Martinez, Julia [1 ]
机构
[1] Hosp Materno Infantil, HRU Carlos Haya, Urgencias Pediat, Malaga, Spain
来源
ENFERMERIA CLINICA | 2009年 / 19卷 / 03期
关键词
Pediatrics; Fever of unknown origin; Body temperature; Triage;
D O I
10.1016/j.enfcli.2008.10.016
中图分类号
R47 [护理学];
学科分类号
1011 ;
摘要
Objectives: To determine the behavior of a new and smaller model of infrared thermometer cone and to assess whether it is an appropriate alternative to determine fever in children under 14-years-old. Method: We performed a cross-sectional, descriptive study comparing the temperatures taken with a mercury thermometer with those taken by an infrared thermometer in children under 14-years-old. The researchers followed the manufacturer's instructions for use for each thermometer. The overall sample of 400 children was divided into two age groups. Group I consisted of children aged less than 2 years and group II of 2-14-years-old. In group I the rectal mercury thermometer was placed in the rectum for 3 minutes and the tympanic thermometer was used in rectal mode and placed in the right ear. In group II, the axillary mercury thermometer was placed for 8 minutes in the right axilla and the tympanic thermometer was used in the axillary mode. To analyze intraobserver bias, 50 patients were selected from the sample and their temperatures were simultaneously taken by two nurses from the team. The intraclass correlation coefficient (ICC) was used both to measure the reliability of the tympanic thermometer and to analyze intraobserver bias. Results: Temperature measurements with both instruments showed an ICC of 0.91 (95% confidence interval [CI], 0.88-0.94) for group I and 0.90 (95% CI, 0.87-0.92) for group II. The reproducibility of the measurements taken by the two nurses in 50 patients showed an ICC of 0.97 (95% CI, 0.95-0.98) for the tympanic thermometer. Conclusions: The infrared thermometer is an appropriate device for rapidly measuring temperature in the emergency department. However, the measurements taken should be confirmed by another method when clinical decisions are based on temperature values. (C) 2008 Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 50 条
  • [1] USE OF A MERCURY-IN-GLASS THERMOMETER AS A DEW-POINT HYGROMETER
    THYER, L
    [J]. JOURNAL OF SCIENTIFIC INSTRUMENTS, 1966, 43 (01): : 43 - &
  • [2] Automated Temperature Scanner Sensor In Comparison With Mercury-In-Glass Thermometer
    Ogidan, Olugbenga Kayode
    Oloruntoba, Olusola
    Babalola, Olusola
    Ajagunna, Oluwatobiloba
    Ajewole, Moses
    [J]. 2022 IEEE NIGERIA 4TH INTERNATIONAL CONFERENCE ON DISRUPTIVE TECHNOLOGIES FOR SUSTAINABLE DEVELOPMENT (IEEE NIGERCON), 2022, : 535 - 540
  • [3] Subjective assessment of fever by parents: Comparison with measurement by noncontact tympanic thermometer and calibrated rectal glass mercury thermometer
    Hooker, EA
    Smith, SW
    Miles, T
    King, L
    [J]. ANNALS OF EMERGENCY MEDICINE, 1996, 28 (03) : 313 - 317
  • [4] Mercury-in-glass thermometer as a cause of neonatal rectal perforations: A report of three cases and review of the literature
    Al-Qahtani, A
    El-Wassabi, A
    Al-Bassam, A
    [J]. ANNALS OF SAUDI MEDICINE, 2001, 21 (1-2) : 59 - 61
  • [5] Clinical Accuracy of Tympanic Thermometer and Noncontact Infrared Skin Thermometer in Pediatric Practice An Alternative for Axillary Digital Thermometer
    Apa, Hursit
    Gozmen, Salih
    Bayram, Nuri
    Catikoglu, Asli
    Devrim, Fatma
    Karaarslan, Utku
    Gunay, Ilker
    Unal, Nurettin
    Devrim, Ilker
    [J]. PEDIATRIC EMERGENCY CARE, 2013, 29 (09) : 992 - 997
  • [6] Withdrawal of mercury glass thermometer is on the agenda
    Pazart, L
    Devilliers, E
    Boute, C
    Aho, S
    Rupin, C
    Gouyon, JB
    [J]. PRESSE MEDICALE, 1997, 26 (05): : 214 - 214
  • [7] TYMPANIC THERMOMETER ACCURACY
    NIERMAN, DM
    [J]. ANNALS OF EMERGENCY MEDICINE, 1992, 21 (10) : 1300 - 1300
  • [8] NONCONTACT TYMPANIC THERMOMETER
    MOORE, JW
    NEWBOWER, RS
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1978, 16 (05) : 580 - 584
  • [9] INFRARED TYMPANIC THERMOMETER - EVALUATION OF A NEW CLINICAL THERMOMETER
    SHINOZAKI, T
    DEANE, R
    PERKINS, FM
    [J]. CRITICAL CARE MEDICINE, 1988, 16 (02) : 148 - 150
  • [10] Glass Thermometer Injuries It Is Not Just About the Mercury
    Aprahamian, Nadine
    Lee, Lois
    Shannon, Michael
    Hummel, David
    Johnston, Patrick
    Kimia, Amir
    [J]. PEDIATRIC EMERGENCY CARE, 2009, 25 (10) : 645 - 647