Real-time MRI-guided needle intervention for cryoablation: A phantom study

被引:0
|
作者
Gao, Wenpeng [1 ]
Jiang, Baichuan [2 ]
Kacher, Dan F. [3 ]
Fetics, Barry [4 ]
Nevo, Erez [4 ]
Lee, Thomas C. [5 ]
Jayender, Jagadeesan [4 ]
机构
[1] Harbin Inst Technol, Sch Life Sci & Technol, Harbin, Peoples R China
[2] Tianjin Univ, Dept Mech Engn, Tianjin, Peoples R China
[3] Brigham & Womens Hosp, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
[4] Robin Med Inc, Baltimore, MD USA
[5] Brigham & Womens Hosp, Dept Neuroradiol, 75 Francis St, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
MRI; Electromagnetic Tracking; Optical Tracking; Needle Intervention; navigation; data fusion;
D O I
10.1117/12.2253958
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
MRI-guided needle intervention for cryoablation is a promising way to relieve the pain and treat the cancer. However, the limited size of MRI bore makes it impossible for clinicians to perform the operation in the bore. The patients had to be moved into the bore for scanning to verify the position of the needle's tip and out for adjusting the needle's trajectory. Real-time needle tracking and shown in MR images is of importance for clinicians to perform the operation more efficiently. In this paper, we have instrumented the cryotherapy needle with a MRI-safe electromagnetic (EM) sensor and optical sensor to measure the needle's position and orientation. To overcome the limitation of line-of-sight for optical sensor and the poor dynamic performance of the EM sensor, Kalman filter based data fusion is developed. Further, we developed a navigation system in open-source software, 3D Slicer, to provide accurate visualization of the needle and the surrounding anatomy. Experiment of simulation the needle intervention at the entrance was performed with a realistic spine phantom to quantify the accuracy of the navigation using the retrospective analysis method. Eleven trials of needle insertion were performed independently. The target accuracy with the navigation using only EM sensor, only optical sensor and data fusion are 2.27 +/- 1.60 mm, 4.11 +/- 1.77 mm and 1.91 +/- 1.10 mm, respectively.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Real-Time MRI-Guided Catheter Tracking Using Hyperpolarized Silicon Particles
    Whiting, Nicholas
    Hu, Jingzhe
    Shah, Jay V.
    Cassidy, Maja C.
    Cressman, Erik
    Millward, Niki Zacharias
    Menter, David G.
    Marcus, Charles M.
    Bhattacharya, Pratip K.
    SCIENTIFIC REPORTS, 2015, 5
  • [32] Deuterium oxide as a contrast medium for real-time MRI-guided endovascular neurointervention
    Chen, Lin
    Liu, Jing
    Chu, Chengyan
    Han, Zheng
    Yadav, Nirhbay
    Xu, Jiadi
    Bai, Renyuan
    Staedtke, Verena
    Pearl, Monica
    Walczak, Piotr
    van Zijl, Peter
    Janowski, Miroslaw
    Liu, Guanshu
    THERANOSTICS, 2021, 11 (13): : 6240 - 6250
  • [33] Real-time MRI-guided hyperthermia treatment using a fast adaptive algorithm
    Stakhursky, Vadim L.
    Arabe, Omar
    Cheng, Kung-Shan
    MacFall, James
    Maccarini, Paolo
    Craciunescu, Oana
    Dewhirst, Mark
    Stauffer, Paul
    Das, Shiva K.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (07): : 2131 - 2145
  • [34] Real-Time MRI-Guided Catheter Tracking Using Hyperpolarized Silicon Particles
    Nicholas Whiting
    Jingzhe Hu
    Jay V. Shah
    Maja C. Cassidy
    Erik Cressman
    Niki Zacharias Millward
    David G. Menter
    Charles M. Marcus
    Pratip K. Bhattacharya
    Scientific Reports, 5
  • [35] Outcomes of Real-Time MRI-guided Lung Stereotactic Body Radiation Therapy
    De Costa, A. M. A.
    Mittauer, K. E.
    Hill, P. M.
    Bassetti, M. F.
    Bayouth, J.
    Baschnagel, A. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E679 - E680
  • [36] MRI-guided abdominal intervention
    K. J. Mortele
    K. Tuncali
    V. Cantisani
    S. Shankar
    E. vanSonnenberg
    C. Tempany
    S. G. Silverman
    Abdominal Imaging, 2003, 28 : 756 - 774
  • [37] MRI-guided abdominal intervention
    Mortele, KJ
    Tuncali, K
    Cantisani, V
    Shankar, S
    vanSonnenberg, E
    Tempany, C
    Silverman, SG
    ABDOMINAL IMAGING, 2003, 28 (06): : 756 - 774
  • [38] MRI-Guided Electrophysiology Intervention
    Halperin, Henry R.
    Kolandaivelu, Aravindan
    RAMBAM MAIMONIDES MEDICAL JOURNAL, 2015, 6 (02):
  • [39] MRI-Guided Electrophysiology Intervention
    Halperin, Henry R.
    Kolandaivelu, Aravindan
    RAMBAM MAIMONIDES MEDICAL JOURNAL, 2010, 1 (02):
  • [40] Commentary: Real-Time MRI-Guided Stereotactic Aspiration of Spontaneous Intracerebral Hematoma: A Preclinical Feasibility Study
    Pearce, John J., III
    Pertsch, Nathan
    Sani, Sepehr
    OPERATIVE NEUROSURGERY, 2022, 22 (05) : E225 - E226