Real-time MRI-guided needle intervention for cryoablation: A phantom study

被引:0
|
作者
Gao, Wenpeng [1 ]
Jiang, Baichuan [2 ]
Kacher, Dan F. [3 ]
Fetics, Barry [4 ]
Nevo, Erez [4 ]
Lee, Thomas C. [5 ]
Jayender, Jagadeesan [4 ]
机构
[1] Harbin Inst Technol, Sch Life Sci & Technol, Harbin, Peoples R China
[2] Tianjin Univ, Dept Mech Engn, Tianjin, Peoples R China
[3] Brigham & Womens Hosp, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
[4] Robin Med Inc, Baltimore, MD USA
[5] Brigham & Womens Hosp, Dept Neuroradiol, 75 Francis St, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
MRI; Electromagnetic Tracking; Optical Tracking; Needle Intervention; navigation; data fusion;
D O I
10.1117/12.2253958
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
MRI-guided needle intervention for cryoablation is a promising way to relieve the pain and treat the cancer. However, the limited size of MRI bore makes it impossible for clinicians to perform the operation in the bore. The patients had to be moved into the bore for scanning to verify the position of the needle's tip and out for adjusting the needle's trajectory. Real-time needle tracking and shown in MR images is of importance for clinicians to perform the operation more efficiently. In this paper, we have instrumented the cryotherapy needle with a MRI-safe electromagnetic (EM) sensor and optical sensor to measure the needle's position and orientation. To overcome the limitation of line-of-sight for optical sensor and the poor dynamic performance of the EM sensor, Kalman filter based data fusion is developed. Further, we developed a navigation system in open-source software, 3D Slicer, to provide accurate visualization of the needle and the surrounding anatomy. Experiment of simulation the needle intervention at the entrance was performed with a realistic spine phantom to quantify the accuracy of the navigation using the retrospective analysis method. Eleven trials of needle insertion were performed independently. The target accuracy with the navigation using only EM sensor, only optical sensor and data fusion are 2.27 +/- 1.60 mm, 4.11 +/- 1.77 mm and 1.91 +/- 1.10 mm, respectively.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] MRI-Guided Real-Time Adaptive Radiotherapy for Liver with Deep Learning
    Wei, R.
    Liang, B.
    Men, K.
    Dai, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2024, 120 (02): : E665 - E665
  • [22] Navigators for motion detection during real-time MRI-guided radiotherapy
    Stam, Mette K.
    Crijns, Sjoerd P. M.
    Zonnenberg, Bernard A.
    Barendrecht, Maurits M.
    van Vulpen, Marco
    Lagendijk, Jan J. W.
    Raaymakers, Bas W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (21): : 6797 - 6805
  • [23] Real-time trajectory guide tracking for intraoperative MRI-guided neurosurgery
    Olsen, Miles E.
    Brodsky, Ethan K.
    Oler, Jonathan A.
    Riedel, Marissa K.
    Mueller, Sascha A. L.
    Vermilyea, Scott C.
    Metzger, Jeanette M.
    Tao, Yunlong
    Brunner, Kevin G.
    Ahmed, Azam S.
    Zhang, Su-Chun
    Emborg, Marina E.
    Kalin, Ned H.
    Block, Walter F.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (02) : 710 - 720
  • [24] Future of medical physics: Real-time MRI-guided proton therapy
    Oborn, Bradley M.
    Dowdell, Stephen
    Metcalfe, Peter E.
    Crozier, Stuart
    Mohan, Radhe
    Keall, Paul J.
    MEDICAL PHYSICS, 2017, 44 (08) : E77 - E90
  • [25] MRI-guided fluorescence tomography of the breast: A phantom study
    Davis, Scott C.
    Pogue, Brian W.
    Dehghani, Hamid
    Paulsen, Keith D.
    MULTIMODAL BIOMEDICAL IMAGING IV, 2009, 7171
  • [26] Phase II Study of Real-Time MRI-Guided Adaptive Accelerated Partial Breast Irradiation
    Harari, Colin
    Yadav, Poonam
    Glide-Hurst, Carri
    Anderson, Bethany
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2024, 47 (10): : S37 - S38
  • [27] Real-Time MRI-Guided Stereotactic Aspiration of Spontaneous Intracerebral Hematoma: A Preclinical Feasibility Study
    Patra, Devi P.
    Welz, Matthew E.
    Turcotte, Evelyn L.
    Pandey, Rajesh
    Vij, Kamal
    Daly, Max
    Rabon, Matthew
    Korszen, Stephanie
    Zhou, Yuxiang
    Halpin, Brooke
    Marchese, Marco L.
    Syal, Arjun
    Krishna, Chandan
    Bendok, Bernard R.
    OPERATIVE NEUROSURGERY, 2022, 22 (02) : 80 - 86
  • [28] Development and validation of a real-time reduced field of view imaging driven by automated needle detection for MRI-guided interventions
    Goerlitz, Roland A.
    Tokuda, Junichi
    Hoge, Scott W.
    Chu, Renxin
    Panych, Lawrence P.
    Tempany, Clare
    Hata, Nobuhiko
    MEDICAL IMAGING 2010: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2010, 7625
  • [29] Real-time cardiorespiratory motion management for MRI-guided stereotactic arrythmia radioablation
    Akdag, O.
    Borman, P.
    Uijtewaal, P.
    Woodhead, P.
    Kok, J.
    Van Asselen, B.
    Raaymakers, B.
    Fast, M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S384 - S385
  • [30] Three-dimensional real-time MRI-guided intracardiac catheter navigation
    Gaspar, Thomas
    Piorkowski, Christopher
    Gutberlet, Matthias
    Hindricks, Gerhard
    EUROPEAN HEART JOURNAL, 2014, 35 (09) : 589