Real-time MRI-guided needle intervention for cryoablation: A phantom study

被引:0
|
作者
Gao, Wenpeng [1 ]
Jiang, Baichuan [2 ]
Kacher, Dan F. [3 ]
Fetics, Barry [4 ]
Nevo, Erez [4 ]
Lee, Thomas C. [5 ]
Jayender, Jagadeesan [4 ]
机构
[1] Harbin Inst Technol, Sch Life Sci & Technol, Harbin, Peoples R China
[2] Tianjin Univ, Dept Mech Engn, Tianjin, Peoples R China
[3] Brigham & Womens Hosp, Dept Radiol, 75 Francis St, Boston, MA 02115 USA
[4] Robin Med Inc, Baltimore, MD USA
[5] Brigham & Womens Hosp, Dept Neuroradiol, 75 Francis St, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
MRI; Electromagnetic Tracking; Optical Tracking; Needle Intervention; navigation; data fusion;
D O I
10.1117/12.2253958
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
MRI-guided needle intervention for cryoablation is a promising way to relieve the pain and treat the cancer. However, the limited size of MRI bore makes it impossible for clinicians to perform the operation in the bore. The patients had to be moved into the bore for scanning to verify the position of the needle's tip and out for adjusting the needle's trajectory. Real-time needle tracking and shown in MR images is of importance for clinicians to perform the operation more efficiently. In this paper, we have instrumented the cryotherapy needle with a MRI-safe electromagnetic (EM) sensor and optical sensor to measure the needle's position and orientation. To overcome the limitation of line-of-sight for optical sensor and the poor dynamic performance of the EM sensor, Kalman filter based data fusion is developed. Further, we developed a navigation system in open-source software, 3D Slicer, to provide accurate visualization of the needle and the surrounding anatomy. Experiment of simulation the needle intervention at the entrance was performed with a realistic spine phantom to quantify the accuracy of the navigation using the retrospective analysis method. Eleven trials of needle insertion were performed independently. The target accuracy with the navigation using only EM sensor, only optical sensor and data fusion are 2.27 +/- 1.60 mm, 4.11 +/- 1.77 mm and 1.91 +/- 1.10 mm, respectively.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Advances in Real-Time MRI-Guided Electrophysiology
    Mukherjee, Rahul K.
    Chubb, Henry
    Roujol, Sebastien
    Razavi, Reza
    O'Neill, Mark D.
    CURRENT CARDIOVASCULAR IMAGING REPORTS, 2019, 12 (02)
  • [2] Real-Time MRI-Guided Prostate Interventions
    Masoom, Seyedeh Nina
    Sundaram, Karthik M.
    Ghanouni, Pejman
    Futterer, Jurgen
    Oto, Aytekin
    Ayyagari, Raj
    Sprenkle, Preston
    Weinreb, Jeffrey
    Arora, Sandeep
    CANCERS, 2022, 14 (08)
  • [3] Real-time probe tracking using EM-optical sensor for MRI-guided cryoablation
    Gao, Wenpeng
    Jiang, Baichuan
    Kacher, Daniel F.
    Fetics, Barry
    Nevo, Erez
    Lee, Thomas C.
    Jayender, Jagadeesan
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2018, 14 (01):
  • [4] A deep unrolled neural network for real-time MRI-guided brain intervention
    He, Zhao
    Zhu, Ya-Nan
    Chen, Yu
    Chen, Yi
    He, Yuchen
    Sun, Yuhao
    Wang, Tao
    Zhang, Chengcheng
    Sun, Bomin
    Yan, Fuhua
    Zhang, Xiaoqun
    Sun, Qing-Fang
    Yang, Guang-Zhong
    Feng, Yuan
    NATURE COMMUNICATIONS, 2023, 14 (01)
  • [5] A deep unrolled neural network for real-time MRI-guided brain intervention
    Zhao He
    Ya-Nan Zhu
    Yu Chen
    Yi Chen
    Yuchen He
    Yuhao Sun
    Tao Wang
    Chengcheng Zhang
    Bomin Sun
    Fuhua Yan
    Xiaoqun Zhang
    Qing-Fang Sun
    Guang-Zhong Yang
    Yuan Feng
    Nature Communications, 14
  • [6] Real-time MRI-guided Radiotherapy for pancreatic cancer
    Rosenberg, S. A.
    Wojcieszynski, A.
    Hullett, C.
    Geurts, M.
    Lubner, S. J.
    LoConte, N. K.
    Deming, D. A.
    Mulkerin, D. L.
    Cho, C. S.
    Weber, S. M.
    Winslow, E.
    Bradley, K. A.
    Bayouth, J.
    Harari, P. M.
    Bassetti, M. F.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S96 - S96
  • [7] Biopsy guided by real-time sonography fused with MRI: A phantom study
    Ewertsen, Caroline
    Grossjohann, Hanne Sonder
    Nielsen, Kristina Rue
    Torp-Pedersen, Soren
    Nielsen, Michael Bachmann
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (06) : 1671 - 1674
  • [8] Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions
    Park, Yong-Lae
    Elayaperumal, Santhi
    Daniel, Bruce
    Ryu, Seok Chang
    Shin, Mihye
    Savall, Joan
    Black, Richard J.
    Moslehi, Behzad
    Cutkosky, Mark R.
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2010, 15 (06) : 906 - 915
  • [9] Real-time MRI-Guided Needle Placement Robot with Integrated Fiber Optic Force Sensing
    Su, Hao
    Zervas, Michael
    Cole, Gregory A.
    Furlong, Cosme
    Fischer, Gregory S.
    2011 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2011, : 1583 - 1588
  • [10] Real-Time MRI-Guided Cardiac Cryo-Ablation: A Feasibility Study
    Kholmovski, Eugene G.
    Coulombe, Nicolas
    Silvernagel, Joshua
    Angel, Nathan
    Parker, Dennis
    Macleod, Rob
    Marrouche, Nassir
    Ranjan, Ravi
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (05) : 602 - 608