Stability of the Human Plasma Proteome to Pre-analytical Variability as Assessed by an Aptamer-Based Approach

被引:14
|
作者
Daniels, Jaclyn R. [1 ]
Cao, Zhijun [1 ]
Maisha, Mackean [2 ]
Schnackenberg, Laura K. [1 ]
Sun, Jinchun [1 ]
Pence, Lisa [1 ]
Schmitt, Thomas C. [1 ]
Kamlage, Beate [3 ]
Rogstad, Sarah [4 ]
Beger, Richard D. [1 ]
Yu, Li-Rong [1 ]
机构
[1] NCTR, Div Syst Biol, US Food & Drug Adm FDA, Jefferson, AR 72079 USA
[2] NCTR, Div Bioinformat & Biostat, FDA, Jefferson, AR 72079 USA
[3] Metan Hlth GmbH, D-10589 Berlin, Germany
[4] FDA, Ctr Drug Evaluat & Res, Silver Spring, MD 20993 USA
关键词
aptamer technology; biomarkers; human blood; plasma; pre-analytical variability; proteomics; quality assessment; BLOOD; SERUM; COLLECTION; BIOMARKERS; VARIABLES; BIOBANKS; QUALITY; SAMPLES; IMPACT; OMICS;
D O I
10.1021/acs.jproteome.9b00320
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Variable processing and storage of whole blood and/or plasma are potential confounders in biomarker development and clinical assays. The goal of the study was to investigate how pre-analytical variables impact the human plasma proteome. Whole blood obtained from 16 apparently healthy individuals was collected in six EDTA tubes and processed randomly under six pre-analytical variable conditions including blood storage at 0 C or RT for 6 h (B6h0C or B6hRT) before processing to plasma, plasma storage at 4 C or RT for 24 h (P24h4C or P24hRT), low centrifugal force at 1300 X g, (Lowxg), and immediate processing to plasma under 2500 X g (control) followed by plasma storage at -80 C. An aptamer-based proteomic assay was performed to identify significantly changed proteins (fold change >= 1.2, P < 0.05, and false discovery rate < 0.05) relative to the control from a total of 1305 proteins assayed. Pre-analytical conditions Lowxg and B6h0C resulted in the most plasma proteome changes with 200 and 148 proteins significantly changed, respectively. Only 36 proteins were changed under B6hRT. Conditions P24h4C and P24hRT yielded changes of 28 and 75 proteins, respectively. The complement system was activated in vitro under the conditions B6hRT, P24h4C, and P24hRT. The results suggest that particular pre-analytical variables should be controlled for clinical measurement of specific biomarkers.
引用
收藏
页码:3661 / 3670
页数:10
相关论文
共 50 条
  • [11] Pre-analytical stability of coagulation parameters in plasma stored at room temperature
    Linskens, E. A.
    Devreese, K. M. J.
    [J]. INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (03) : 292 - 303
  • [12] The stability of the circulating human proteome to variations in sample collection and handling procedures measured with an aptamer-based proteomics array
    Ostroff, Rachel
    Foreman, Trudi
    Keeney, Tracy R.
    Stratford, Suzanne
    Walker, Jeffrey J.
    Zichi, Dom
    [J]. JOURNAL OF PROTEOMICS, 2010, 73 (03) : 649 - 666
  • [13] An RNA aptamer-based approach for human glioma treatment
    Camorani, Simona
    Esposito, Carla L.
    Catuogno, Silvia
    Amero, Paola
    Rienzo, Anna
    Vita, Gennaro D.
    Condorelli, Gerolama
    de Franciscis, Vittorio
    Cerchia, Laura
    [J]. CANCER RESEARCH, 2014, 74 (19)
  • [14] Pre-analytical variability of the Lumipulse immunoassay for plasma biomarkers of Alzheimer's disease
    Musso, Giulia
    Cosma, Chiara
    Zaninotto, Martina
    Gabelli, Carlo
    Basso, Daniela
    Plebani, Mario
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2023, 61 (03) : E53 - E56
  • [15] A new approach to the pre-analytical phase of venous plasma glucose analysis
    Dorofeykov, V.
    [J]. CLINICA CHIMICA ACTA, 2019, 493 : S269 - S269
  • [16] Seven day pre-analytical stability of serum and plasma neurofilament light chain
    Patrick Altmann
    Markus Ponleitner
    Paulus Stefan Rommer
    Helmuth Haslacher
    Patrick Mucher
    Fritz Leutmezer
    Axel Petzold
    Christoph Wotawa
    Rupert Lanzenberger
    Thomas Berger
    Henrik Zetterberg
    Gabriel Bsteh
    [J]. Scientific Reports, 11
  • [17] Seven day pre-analytical stability of serum and plasma neurofilament light chain
    Altmann, Patrick
    Ponleitner, Markus
    Rommer, Paulus Stefan
    Haslacher, Helmuth
    Mucher, Patrick
    Leutmezer, Fritz
    Petzold, Axel
    Wotawa, Christoph
    Lanzenberger, Rupert
    Berger, Thomas
    Zetterberg, Henrik
    Bsteh, Gabriel
    [J]. SCIENTIFIC REPORTS, 2021, 11 (01)
  • [18] Aptamer-based assay of biomolecules: Recent advances in electro-analytical approach
    Hasanzadeh, Mohammad
    Shadjou, Nasrin
    de la Guardia, Miguel
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2017, 89 : 119 - 132
  • [19] Pre-analytical factors affecting ascorbic and uric acid quantification in human plasma
    Zinellu, Angelo
    Sotgia, Salvatore
    Deiana, Luca
    Carru, Ciriaco
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2006, 67 (2-3): : 95 - 105
  • [20] Pre-Analytical Variables Influencing Stability of Blood-Based Biomarkers of Neuropathology
    Panikkar, Daniel
    Vivek, Sithara
    Crimmins, Eileen
    Faul, Jessica
    Langa, Kenneth M.
    Thyagarajan, Bharat
    [J]. JOURNAL OF ALZHEIMERS DISEASE, 2023, 95 (02) : 735 - 748