Accuracy of diffuse correlation spectroscopy measurements of cerebral blood flow when using a three-layer analytical model

被引:20
|
作者
Zhao, Hongting [1 ,2 ]
Sathialingam, Eashani [1 ,2 ]
Buckley, Erin M. [1 ,2 ,3 ,4 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, 1760 Haygood Dr NE, Atlanta, GA 30322 USA
[2] Emory Univ, 1760 Haygood Dr NE, Atlanta, GA 30322 USA
[3] Emory Univ, Dept Pediat, Sch Med, 2015 Uppergate Dr, Atlanta, GA 30322 USA
[4] Childrens Healthcare Atlanta, 2015 Uppergate Dr, Atlanta, GA 30322 USA
基金
美国国家卫生研究院;
关键词
OPTICAL-PROPERTIES; HEMODYNAMICS; TOMOGRAPHY; METABOLISM; TISSUES; SCALP; MRI;
D O I
10.1364/BOE.438303
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Diffuse correlation spectroscopy (DCS) is a non-invasive optical technology for the assessment of an index of cerebral blood flow (CBFi). Analytical methods that model the head as a three-layered medium (i.e., scalp, skull, brain) are becoming more commonly used to minimize the contribution of extracerebral layers to the measured DCS signal in adult cerebral blood flow studies. However, these models rely on a priori knowledge of layer optical properties and thicknesses. Errors in these values can lead to errors in the estimation of CBFi, although the magnitude of this influence has not been rigorously characterized. Herein, we investigate the accuracy of measuring cerebral blood flow with a three-layer model when errors in layer optical properties or thicknesses are present. Through a series of in silico experiments, we demonstrate that CBFi is highly sensitive to errors in brain optical properties and skull and scalp thicknesses. Relative changes in CBFi are less sensitive to optical properties but are influenced by errors in layer thickness. Thus, when using the three-layer model, accurate estimation of scalp and skull thickness are required for reliable results. (c) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:7149 / 7161
页数:13
相关论文
共 50 条
  • [41] Evaluation of blood flow in human exercising muscle by diffuse correlation spectroscopy: a phantom model study
    Nakabayashi, Mikie
    Ono, Yumie
    Ichinose, Masashi
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES XI, 2018, 10486
  • [42] Estimating intracranial pressure using pulsatile cerebral blood flow measured with diffuse correlation spectroscopy (vol 11, pg 1462, 2020)
    Ruesch, Alexander
    Yang, Jason
    Schmitt, Samantha
    Acharya, Deepshikha
    Smith, Matthew A.
    Kainerstorfer, Jana M.
    BIOMEDICAL OPTICS EXPRESS, 2022, 13 (02): : 710 - 712
  • [43] Modeling mass transfer in a Taylor flow regime through microchannels using a three-layer model
    S. D. Svetlov
    R. Sh. Abiev
    Theoretical Foundations of Chemical Engineering, 2016, 50 : 975 - 989
  • [44] Modeling mass transfer in a Taylor flow regime through microchannels using a three-layer model
    Svetlov, S. D.
    Abiev, R. Sh.
    THEORETICAL FOUNDATIONS OF CHEMICAL ENGINEERING, 2016, 50 (06) : 975 - 989
  • [45] Time-domain diffuse correlation spectroscopy at large source detector separation for cerebral blood flow recovery
    Mogharari, Neda
    Wojtkiewicz, Stanislaw
    Borycki, Dawid
    Liebert, Adam
    Kacprzak, Michal
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (07): : 4330 - 4344
  • [46] Quantification of blood flow index in diffuse correlation spectroscopy using a robust deep learning method
    Wang, Quan
    Pan, Mingliang
    Zang, Zhenya
    Li, David Day-Uei
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 (01)
  • [47] Validation of diffuse correlation spectroscopy measurements of rodent cerebral blood flow with simultaneous arterial spin labeling MRI; towards MRI-optical continuous cerebral metabolic monitoring
    Carp, S. A.
    Dai, G. P.
    Boas, D. A.
    Franceschini, M. A.
    Kim, Y. R.
    BIOMEDICAL OPTICS EXPRESS, 2010, 1 (02): : 553 - 565
  • [48] Deep-learning-based separation of shallow and deep layer blood flow rates in diffuse correlation spectroscopy
    Nakabayashi, Mikie
    Liu, Siwei
    Broti, Nawara Mahmood
    Ichinose, Masashi
    Ono, Yumie
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (10) : 5358 - 5375
  • [49] Speckle contrast diffuse correlation tomography of cerebral blood flow in perinatal disease model of neonatal piglets
    Huang, Chong
    Mazdeyasna, Siavash
    Mohtasebi, Mehrana
    Saatman, Kathryn E.
    Cheng, Qiang
    Yu, Guoqiang
    Chen, Lei
    JOURNAL OF BIOPHOTONICS, 2021, 14 (04)
  • [50] Dissecting the microvascular contributions to diffuse correlation spectroscopy measurements of cerebral hemodynamics using optical coherence tomography angiography
    Jang, James H.
    Solarana, Krystyna
    Hammer, Daniel X.
    Fisher, Jonathan A. N.
    NEUROPHOTONICS, 2021, 8 (02)