Accuracy of diffuse correlation spectroscopy measurements of cerebral blood flow when using a three-layer analytical model

被引:20
|
作者
Zhao, Hongting [1 ,2 ]
Sathialingam, Eashani [1 ,2 ]
Buckley, Erin M. [1 ,2 ,3 ,4 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, 1760 Haygood Dr NE, Atlanta, GA 30322 USA
[2] Emory Univ, 1760 Haygood Dr NE, Atlanta, GA 30322 USA
[3] Emory Univ, Dept Pediat, Sch Med, 2015 Uppergate Dr, Atlanta, GA 30322 USA
[4] Childrens Healthcare Atlanta, 2015 Uppergate Dr, Atlanta, GA 30322 USA
基金
美国国家卫生研究院;
关键词
OPTICAL-PROPERTIES; HEMODYNAMICS; TOMOGRAPHY; METABOLISM; TISSUES; SCALP; MRI;
D O I
10.1364/BOE.438303
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Diffuse correlation spectroscopy (DCS) is a non-invasive optical technology for the assessment of an index of cerebral blood flow (CBFi). Analytical methods that model the head as a three-layered medium (i.e., scalp, skull, brain) are becoming more commonly used to minimize the contribution of extracerebral layers to the measured DCS signal in adult cerebral blood flow studies. However, these models rely on a priori knowledge of layer optical properties and thicknesses. Errors in these values can lead to errors in the estimation of CBFi, although the magnitude of this influence has not been rigorously characterized. Herein, we investigate the accuracy of measuring cerebral blood flow with a three-layer model when errors in layer optical properties or thicknesses are present. Through a series of in silico experiments, we demonstrate that CBFi is highly sensitive to errors in brain optical properties and skull and scalp thicknesses. Relative changes in CBFi are less sensitive to optical properties but are influenced by errors in layer thickness. Thus, when using the three-layer model, accurate estimation of scalp and skull thickness are required for reliable results. (c) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:7149 / 7161
页数:13
相关论文
共 50 条
  • [21] Clinical applications of high-speed blood flow measurements with Diffuse Correlation Spectroscopy
    Parthasarathy, Ashwin B.
    Baker, Wesley B.
    Gannon, Kimberly
    Mullen, Michael T.
    Detre, John A.
    Yodh, Arjun G.
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE XII, 2017, 10059
  • [22] Deep learning model for ultrafast quantification of blood flow in diffuse correlation spectroscopy
    Poon, Chien-Sing
    Long, Feixiao
    Sunar, Ulas
    BIOMEDICAL OPTICS EXPRESS, 2020, 11 (10) : 5557 - 5564
  • [23] Study of Effect of Different Shapes of Nanoparticles in Three-Layer Model for Blood Flow in Arterioles
    Bali, Rekha
    Prasad, Bhawini
    Mishra, Swati
    CONTEMPORARY MATHEMATICS, 2022, 3 (03): : 270 - 287
  • [24] Development of Near-Infrared Diffuse Correlation Spectroscopy for Noninvasive Monitoring of Cerebral Blood Flow
    Huang, I-Tseng
    Wu, Kuan-Chen
    Chen, Jia-Jin
    2ND INTERNATIONAL CONFERENCE FOR INNOVATION IN BIOMEDICAL ENGINEERING AND LIFE SCIENCES, 2018, 67 : 231 - 234
  • [25] Prolonged monitoring of cerebral blood flow and autoregulation with diffuse correlation spectroscopy in neurocritical care patients
    Selb, Juliette
    Wu, Kuan-Cheng
    Sutin, Jason
    Lin, Pei-Yi
    Farzam, Parisa
    Bechek, Sophia
    Shenoy, Apeksha
    Patel, Aman B.
    Boas, David A.
    Franceschini, Maria Angela
    Rosenthal, Eric S.
    NEUROPHOTONICS, 2018, 5 (04)
  • [26] Enhancing diffuse correlation spectroscopy pulsatile cerebral blood flow signal with near-infrared spectroscopy photoplethysmography
    Wu, Kuan Cheng
    Martin, Alyssa
    Renna, Marco
    Robinson, Mitchell
    Ozana, Nisan
    Carp, Stefan A.
    Franceschini, Maria Angela
    NEUROPHOTONICS, 2023, 10 (03)
  • [27] Optimizing a two-layer method for hybrid diffuse correlation spectroscopy and frequency-domain diffuse optical spectroscopy cerebral measurements in adults
    Forti, Rodrigo Menezes
    Martins, Giovani Grisotti
    Baker, Wesley Boehs
    Mesquita, Rickson C.
    NEUROPHOTONICS, 2023, 10 (02)
  • [28] Effects of muscle fiber motion on diffuse correlation spectroscopy blood flow measurements during exercise
    Shang, Yu
    Symons, T. B.
    Durduran, Turgut
    Yodh, A. G.
    Yu, Guoqiang
    BIOMEDICAL OPTICS EXPRESS, 2010, 1 (02): : 500 - 511
  • [29] Calibration of diffuse correlation spectroscopy with a time-resolved near-infrared technique to yield absolute cerebral blood flow measurements
    Diop, Mamadou
    Verdecchia, Kyle
    Lee, Ting-Yim
    St Lawrence, Keith
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (07): : 2068 - 2082
  • [30] Influence of probe pressure on the diffuse correlation spectroscopy blood flow signal: extra-cerebral contributions
    Mesquita, Rickson C.
    Schenkel, Steven S.
    Minkoff, David L.
    Lu, Xiangping
    Favilla, Christopher G.
    Vora, Patrick M.
    Busch, David R.
    Chandra, Malavika
    Greenberg, Joel H.
    Detre, John A.
    Yodh, A. G.
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (07): : 978 - 994