Comparison Test and its Evaluation of Flowmeters for Heat Meter

被引:0
|
作者
Choi, Hae-Man [1 ]
Choi, Yong-Moon [1 ]
Yoon, Byung-Ro [1 ]
机构
[1] Korea Res Inst Stand & Sci, Div Phys Metrol, Taejon 305340, South Korea
关键词
heat meter; impeller; electromagnetic; ultrasonic; OIML R 75;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
This study selected a total of 24 heat flowmeters consisting of three types: impeller, electromagnetic and ultrasonic, 8 meters each. The diameter Was 0.05 m (9 meters), 0.08 m (9 meters), and 0.15 m (6 meters). In accordance with the OIML R 75 testing method accuracy, installation position, external environment, and durability were tested, and the flowmeter property field test was conducted in the field where of heat supply from winter to summer in order to select the type of heat flowmeter best suited for the circumstances in Korea. According to the test result, all 3 types of flowmeters met the OIML Recommendation, but the result of the field test showed that the electromagnetic flowmeters displayed a deviation at the low flow rate during summer. The impeller flowmeters showed accuracy suggested by the OIML Recommendation, but the ultrasonic flowmeter, a next-generation flowmeter, which is strong against contamination, low in maintenance-rate, and high in accuracy as it has no moving part, was found to be the best choice.
引用
收藏
页码:1060 / 1069
页数:10
相关论文
共 50 条
  • [1] Evaluation of flowmeters for heat metering
    Choi, Hae Man
    Yoon, Byung Ro
    Kim, Chul Gyun
    Choi, Yong Moon
    FLOW MEASUREMENT AND INSTRUMENTATION, 2011, 22 (05) : 475 - 481
  • [2] The heat meter test programme of AGFW
    Kestner, Martin
    Espig, Frank
    Euroheat and Power (English Edition), 2012, 9 (02): : 43 - 47
  • [3] Heat microprocessor flowmeters
    Sokolov, G.A.
    Novichkov, Yu.A.
    Lyashenko, A.A.
    Teploenergetika, 1994, (06): : 65 - 67
  • [4] ACCURACY OF GAS FLOWMETERS DETERMINED BY THE BUBBLE METER METHOD
    WAABEN, J
    STOKKE, DB
    BRINKLOV, MM
    BRITISH JOURNAL OF ANAESTHESIA, 1978, 50 (12) : 1251 - 1256
  • [5] COMPARISON OF TURBINE AND VORTEX FLOWMETERS
    COUSINS, T
    NICHOLL, AJ
    BROWN BOVERI REVIEW, 1977, 64 (03): : 156 - 162
  • [6] TEST OF DIGITAL VSA SEA GRAVITY METER AND COMPARISON WITH LACOSTE AND ROMBERG GYROSTABILIZED GRAVITY METER
    BOWIN, CO
    FOLINSBE.A
    ALDRICH, TC
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1970, 51 (04): : 261 - &
  • [7] COMPARISON OF TURBINE AND VORTEX FLOWMETERS
    COUSINS, T
    NICHOLL, AJ
    CME-CHARTERED MECHANICAL ENGINEER, 1978, 25 (02): : 35 - 38
  • [8] COMPARISON OF CALORIMETRIC AND FLUX METER MEASUREMENTS OF SOIL HEAT FLOW
    HANKS, RJ
    JACOBS, HS
    SOIL SCIENCE SOCIETY OF AMERICA PROCEEDINGS, 1971, 35 (05): : 671 - &
  • [9] Influence of heat flowmeters on thermal measurements
    Langlet, T
    Roucoult, JM
    Douzane, O
    Devisme, JM
    HIGH TEMPERATURES-HIGH PRESSURES, 2000, 32 (03) : 347 - 353
  • [10] Comparison of Various Analysis Methods Based on Heat Flowmeters and Infrared Thermography Measurements for the Evaluation of the In Situ Thermal Transmittance of Opaque Exterior Walls
    Choi, Doo Sung
    Ko, Myeong Jin
    ENERGIES, 2017, 10 (07):