Comparison of Various Analysis Methods Based on Heat Flowmeters and Infrared Thermography Measurements for the Evaluation of the In Situ Thermal Transmittance of Opaque Exterior Walls

被引:29
|
作者
Choi, Doo Sung [1 ]
Ko, Myeong Jin [2 ]
机构
[1] Chungwoon Univ, Dept Bldg Equipment & Fire Protect Syst, Incheon 22100, South Korea
[2] Nabi Bldg Environm & Equipment Design Consultant, Seoul 06226, South Korea
来源
ENERGIES | 2017年 / 10卷 / 07期
关键词
in situ thermal transmittance; heat flowmeter; infrared thermography; on-site measurement; opaque exterior wall; BUILDING DIAGNOSTICS; U-VALUE; CONSTRUCTION; PERFORMANCE; COMPONENTS; RESISTANCE; FLOW;
D O I
10.3390/en10071019
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
There are several methods to obtain the in situ thermal transmittance value (U-value) of building envelopes from on-site data, including the three approaches of the progressive average method, average method considering the thermal storage effect, and dynamic method for deriving the U-value from heat flowmeter (HFM) measurements and the four methods with different formulas to analyze infrared thermography (IRT) measurement data. Since each of these methods considers different parameters and the non-steady characteristics of the heat transfer in building walls in their own way, discrepancies may occur among the obtained results. This study evaluates and compares the in situ U-values by using various methods of analyzing HFM and IRT measurement data. Further, by investigating buildings with similar materials and identical stratigraphies, but with different construction years, we analyze the discrepancy between the designed and measured values caused by material deterioration and evaluate the errors according to the analysis method. The percentage deviation between the U-values obtained by the three methods from the HFM data is found to be satisfactory, being within 10%. When compared with the results of the progressive average method, the deviations for the four different IRT-measurement-based methods vary greatly, being in the range of 6-43%.
引用
收藏
页数:22
相关论文
共 13 条
  • [1] Comparison of Infrared Thermography and Heat Flux Method for Dynamic Thermal Transmittance Determination
    Gasi, Mergim
    Milovanovic, Bojan
    Gumbarevic, Sanjin
    BUILDINGS, 2019, 9 (05)
  • [2] Analysis of Convergence Characteristics of Average Method Regulated by ISO 9869-1 for Evaluating In Situ Thermal Resistance and Thermal Transmittance of Opaque Exterior Walls
    Choi, Doo Sung
    Ko, Myeong Jin
    ENERGIES, 2019, 12 (10)
  • [3] An in-situ detection method for assessing the thermal transmittance of building exterior walls using unmanned aerial vehicle-infrared thermography (UAV-IRT)
    Zhang, Dongjie
    Zhan, Changhong
    Chen, Lin
    Wang, Yongjie
    Li, Guanghao
    JOURNAL OF BUILDING ENGINEERING, 2024, 91
  • [4] Review and comparison of current experimental approaches for in-situ measurements of building walls thermal transmittance
    Teni, Mihaela
    Krstic, Hrvoje
    Kosinski, Piotr
    ENERGY AND BUILDINGS, 2019, 203
  • [5] Skin temperature evaluation by infrared thermography: Comparison of image analysis methods
    Ludwig, N.
    Formenti, D.
    Gargano, M.
    Alberti, G.
    INFRARED PHYSICS & TECHNOLOGY, 2014, 62 : 1 - 6
  • [6] Infrared thermography for the investigation of dynamic thermal behaviour of opaque building elements: Comparison between empty and filled with hemp fibres prototype walls
    Aversa, Patrizia
    Palumbo, Davide
    Donatelli, Antonio
    Tamborrino, Rosanna
    Ancona, Francesco
    Galietti, Umberto
    Luprano, Vincenza Anna Maria
    ENERGY AND BUILDINGS, 2017, 152 : 264 - 272
  • [7] In-situ heat loss measurements of parabolic trough receivers based on transient infrared thermography
    Caron, S.
    Roger, M.
    SOLAR ENERGY, 2016, 135 : 111 - 121
  • [8] In-situ measurement of thermal transmittance of building walls: Evaluation of stored heat flux in heavy-weight walls during the cooling season
    Jung, Dong Eun
    Yoo, Seunghwan
    Lee, Kwang Ho
    Kim, Jonghun
    ENERGY AND BUILDINGS, 2024, 325
  • [9] Thermal transmittance of historical brick masonries: A comparison among standard data, analytical calculation procedures, and in situ heat flow meter measurements
    Lucchi, Elena
    ENERGY AND BUILDINGS, 2017, 134 : 171 - 184
  • [10] Skin temperature evaluation by infrared thermography: Comparison of two image analysis methods during the nonsteady state induced by physical exercise
    Formenti, Damiano
    Ludwig, Nicola
    Rossi, Alessio
    Trecroci, Athos
    Alberti, Giampietro
    Gargano, Marco
    Merla, Arcangelo
    Ammer, Kurt
    Caumo, Andrea
    INFRARED PHYSICS & TECHNOLOGY, 2017, 81 : 32 - 40