Comparison Test and its Evaluation of Flowmeters for Heat Meter

被引:0
|
作者
Choi, Hae-Man [1 ]
Choi, Yong-Moon [1 ]
Yoon, Byung-Ro [1 ]
机构
[1] Korea Res Inst Stand & Sci, Div Phys Metrol, Taejon 305340, South Korea
关键词
heat meter; impeller; electromagnetic; ultrasonic; OIML R 75;
D O I
暂无
中图分类号
O59 [应用物理学];
学科分类号
摘要
This study selected a total of 24 heat flowmeters consisting of three types: impeller, electromagnetic and ultrasonic, 8 meters each. The diameter Was 0.05 m (9 meters), 0.08 m (9 meters), and 0.15 m (6 meters). In accordance with the OIML R 75 testing method accuracy, installation position, external environment, and durability were tested, and the flowmeter property field test was conducted in the field where of heat supply from winter to summer in order to select the type of heat flowmeter best suited for the circumstances in Korea. According to the test result, all 3 types of flowmeters met the OIML Recommendation, but the result of the field test showed that the electromagnetic flowmeters displayed a deviation at the low flow rate during summer. The impeller flowmeters showed accuracy suggested by the OIML Recommendation, but the ultrasonic flowmeter, a next-generation flowmeter, which is strong against contamination, low in maintenance-rate, and high in accuracy as it has no moving part, was found to be the best choice.
引用
收藏
页码:1060 / 1069
页数:10
相关论文
共 50 条
  • [41] PIPEFLOW DOWNSTREAM OF A REDUCER AND ITS EFFECTS ON FLOWMETERS
    YEH, TT
    MATTINGLY, GE
    FLOW MEASUREMENT AND INSTRUMENTATION, 1994, 5 (03) : 181 - 187
  • [42] The heat value of milk as a test of its quality
    Malcolm, J
    Hall, AA
    JOURNAL OF AGRICULTURAL SCIENCE, 1907, 2 : 89 - 95
  • [43] Evaluation of a field test with retrofit heat pumps
    Huchtemann, Kristian
    Mueller, Dirk
    BUILDING AND ENVIRONMENT, 2012, 53 : 100 - 106
  • [44] AN EVALUATION OF THE ACCURACY OF ASSESS AND MINIWRIGHT PEAK FLOWMETERS
    SHAPIRO, SM
    HENDLER, JM
    OGIRALA, RG
    ALDRICH, TK
    SHAPIRO, MB
    CHEST, 1991, 99 (02) : 358 - 362
  • [45] AIRBORNE GRAVITY METER TEST
    THOMPSON, LGD
    JOURNAL OF GEOPHYSICAL RESEARCH, 1959, 64 (04): : 488 - 488
  • [46] Undersea corrosion test meter
    不详
    NAVAL ARCHITECT, 1998, : 21 - 21
  • [47] TEST OF AN AIRBORNE GRAVITY METER
    ZHANG, SY
    ZHOU, DM
    ZONG, J
    FANG, M
    WANG, JD
    SHAN, JH
    ZHOU, BL
    MIAO, H
    ACTA GEOPHYSICA SINICA, 1990, 33 (01): : 70 - 76
  • [48] Checkout test of reactivity meter
    Han, Changan
    Hedongli Gongcheng/Nuclear Power Engineering, 1993, 14 (01): : 79 - 82
  • [49] FALSE ECONOMY + HEAT METER
    MONSON, JE
    ARCHITECTS JOURNAL, 1979, 170 (51-5): : 1304 - 1304
  • [50] AN ELECTRONIC INTEGRATING HEAT METER
    KUSUI, S
    NAGAI, T
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1990, 39 (05) : 785 - 789