Dosimetric characteristics of a 2D silicon diode array for stereotactic radiotherapy end-to-end patient-specific QA

被引:4
|
作者
Bai, Long [1 ,2 ]
Xiao, Qing [1 ,2 ]
Wang, Qiang [1 ,2 ]
Zhao, Jianling [1 ,2 ]
Li, Guangjun [1 ,2 ]
Bai, Sen [2 ]
机构
[1] Sichuan Univ, West China Hosp, Canc Ctr, Dept Radiat Oncol, Chengdu 610041, Sichuan, Peoples R China
[2] Sichuan Univ, West China Hosp, State Key Lab Biotherapy, Chengdu 610041, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Dosimetric characteristics; Diode array; Stereotactic radiotherapy; Patient-specific QA; Volumetric modulated arc therapy; IONIZATION-CHAMBER ARRAYS; BODY RADIATION-THERAPY; SMALL-FIELD DOSIMETRY; CELL LUNG-CANCER; QUALITY-ASSURANCE; DETECTOR ARRAY; IMRT; RESOLUTION; VERIFICATION; RADIOSURGERY;
D O I
10.1016/j.radphyschem.2020.108885
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The measurement accuracy of stereotactic radiotherapy (SRT) patient-specific quality assurance (QA) is challenging as small-field dosimetry contains lateral charge disequilibrium, partial blocking of the beam source, and limitations based on the detector size. The aim of this study was to investigate the dosimetric characteristics of a two-dimensional high-resolution silicon diode array for SRT end-to-end patient-specific QA. The dosimetric characteristics of the diode array, delivered to an end-to-end QA phantom, were evaluated for 6 MV, with a flattening filter (FF) and flattening filter-free (FFF), and 10 MV FFF photon beams. Dose linearity, dose rate dependence, dose-per-pulse dependence, field size dependence, angular dependence, and beam directivity were investigated for all photon beams. A total of 27 clinical plans were selected to evaluate the SRT end-to-end patient-specific QA for treatment delivery using volumetric modulated arc therapy (VMAT). For all beam qualifies, the differences of dose and dose rate linearity of the diode array were below 0.7% (10-1400 MU range) and 0.6% (100-2400 MU/min range), respectively. The diodes had a decrease in sensitivity of about 4% for the 21-fold decrease in dose-per-pulse. Output factors were in good agreement for field size down to 2 x 2 cm(2) (< 0.6% for both 6 MV FF and FFF beams, < 1.6% for the 10 MV FFF beam), while the field size down to 0.6 x 0.6 cm(2) had an under-response (< 4% for all beam qualifies). Angular dependence was within +/- 2% and +/- 4%, for coplanar and non-coplanar beams, respectively. However, this was not the case for the beam direction nearly parallel to the diode array plane. Beam directivity response on both sides of the array was in excellent agreement. For the end-to-end patient-specific QA, the average gamma passing rate (GPR) with a 2%/1 mm criterion was 96.8% and the minimum value was 93.0%. There was no significant difference in the GPRs between coplanar and non-coplanar VMAT plans. The diode array, with several corrections, demonstrated good dosimetric characteristics for SRT QA. The GPRs of end-to-end patient-specific QA for non-coplanar and multiple metastases were as high as that for coplanar and single-target, and a gamma criterion of 2%/1 mm would be suitable for SRT QA when using the array.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Development of Correction Factors for a 2D Ion Chamber Array Inserted in a Cubic and Homogeneous Phantom for VMAT Patient-Specific QA
    Clemente, F.
    Perez-Vara, C.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [22] A patient-specific QA comparison between 2D and 3D diode arrays for single-lesion SRS and SBRT treatments
    Lee, Yongsook C.
    Kim, Yongbok
    [J]. JOURNAL OF RADIOSURGERY AND SBRT, 2021, 7 (04): : 295 - 307
  • [23] End-to-End testing method for SRS patient QA based on a new multidetector array and comparison with two other techniques
    Buchauer, Konrad
    Buchauer, K.
    Toquant, A. Socoliuc
    Plasswilm, L.
    Schiefer, H.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1133 - 1133
  • [24] Personalized End-to-End QA in Cranial SRS: Evaluation of the Phantom-to-Patient Dosimetric Equivalency of a 3D Printed Phantom using Film Dosimetry
    Pappas, E.
    Makris, D.
    Zoros, E.
    Kalaitzakis, G.
    Boursianis, T.
    Papanikolaou, N.
    Hourdakis, C.
    Zourari, K.
    Lahanas, V.
    Maris, T.
    Efstathopoulos, E.
    Pappas, E.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E485 - E486
  • [25] Dosimetric evaluation of a 2D ionisation chamber array for application for IMRT QA
    Herzen, J.
    Todorovic, M.
    Cremers, F.
    Platz, V.
    Albers, D.
    Fischer, M.
    Thom, E.
    Schmidt, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S463 - S463
  • [26] Utility of 2D Diode Array for Electron Beam QA and Commissioning
    Ghasroddashti, E.
    Sawchuk, S.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [27] Curtailing patient-specific IMRT QA procedures from 2D dose error distribution
    Kurosu, Keita
    Sumida, Iori
    Mizuno, Hirokazu
    Otani, Yuki
    Oda, Michio
    Isohashi, Fumiaki
    Seo, Yuji
    Suzuki, Osamu
    Ogawa, Kazuhiko
    [J]. JOURNAL OF RADIATION RESEARCH, 2016, 57 (03) : 258 - 264
  • [28] Implementing and evaluating a high-resolution diode array for patient-specific quality assurance of robotic brain stereotactic radiosurgery/radiotherapy
    Xu, Qianyi
    Huynh, Kiet
    Nie, Wei
    Rose, Mark S.
    Chawla, Ashish K.
    Choe, Kevin S.
    Kanani, Samir
    Kubicek, Gregory J.
    Fan, Jiajin
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2022, 23 (05):
  • [29] VOLUMETRIC-MODULATED ARC THERAPY: EFFECTIVE AND EFFICIENT END-TO-END PATIENT-SPECIFIC QUALITY ASSURANCE
    O'Daniel, Jennifer
    Das, Shiva
    Wu, Q. Jackie
    Yin, Fang-Fang
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1567 - 1574
  • [30] DOSIMETRIC INVESTIGATION OF PATIENT SPECIFIC QA USING FOUR DIFFERENT COMMERCIAL 2D DETECTORS.
    Yamada, M.
    Oita, M.
    Kai, K.
    Ogawa, K.
    Matsuda, K.
    Iwasaki, K.
    Kuroda, S.
    Takahashi, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S510 - S510