A patient-specific QA comparison between 2D and 3D diode arrays for single-lesion SRS and SBRT treatments

被引:2
|
作者
Lee, Yongsook C. [1 ]
Kim, Yongbok [2 ]
机构
[1] Miami Canc Inst, Dept Radiat Oncol, 8900 N Kendall Dr, Miami, FL 33176 USA
[2] Duke Univ, Dept Radiat Oncol, Durham, NC 27710 USA
来源
JOURNAL OF RADIOSURGERY AND SBRT | 2021年 / 7卷 / 04期
关键词
Patient-specific quality assurance (PSQA); SRS MapCHECK; ArcCHECK; stereotactic radiosurgery (SRS); stereotactic body radiation therapy (SBRT); MODULATED ARC THERAPY; PRETREATMENT QUALITY-ASSURANCE; RADIATION-THERAPY; ARCCHECK; VMAT;
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
The purpose of this study is to compare patient-specific quality assurance (PSQA) results between two dimensional (2D) diode (SRS MapCHECK (R)) and 3D diode (ArcCHECK (R)) arrays. Twenty-eight intracranial stereotactic radiosurgery (SRS) and 26 lung stereotactic body radiation therapy (SBRT) clinical plans with a single lesion were selected and categorized into 4 groups: 20 SRS dynamic conformal arc therapy (DCAT) plans (Group A), 8 SRS volumetric modulated arc therapy (VMAT) plans (Group B), 6 SBRT DCAT plans (Group C) and 20 SBRT VMAT plans (Group D). An individual field of each plan was delivered on SRS MapCHECK and ArcCHECK and QA analysis was performed using 4 gamma criteria of dose difference/distance-to-agreement of 3%/3 mm, 3%/2 mm, 2%/2 mm and 2%/1 mm. Statistical analysis was performed to compare PSQA results between the 2 QA devices. For all 4 groups and all 4 gamma criteria, average gamma passing rates were higher with SRS MapCHECK.
引用
收藏
页码:295 / 307
页数:13
相关论文
共 50 条
  • [1] Quantitative Comparison of 2D and 3D Modes of a Commercial EPID-Based Hybrid Patient-Specific QA System for Spine SBRT Treatments
    Ahmed, S.
    Bojorquez, J. Zavala
    Qi, P.
    Chao, S.
    Murphy, E.
    Suh, J.
    Xia, P.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [2] Implementation of 2D Arrays for TomoTherapy Patient-Specific QA
    Winningham, T.
    Staton, R.
    Meeks, S.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [3] Comparison of 2D and 3D Gamma Analysis in Patient-Specific QA for Prostate VMAT Plans
    Clemente, F.
    Perez, C.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 240 - +
  • [4] Performance of the Mobius 3D software for cranial SRS patient-specific QA
    Calvo-Ortega, J.
    Hermida-Lopez, M.
    Laosa-Bello, C.
    Moragues-Femenia, S.
    Caslas-Farran, J.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1315 - S1316
  • [5] Patient-specific quality assurance in SBRT treatments using 3D polymer gel dosimetry
    Guadarrama-Huerta, P. J.
    Arzaga-Barajas, E.
    Rodriguez-Laguna, A.
    Jimenez-Acosta, J. A.
    Poitevin-Chacon, M. A.
    Massillon-Jl, G.
    [J]. RADIATION MEASUREMENTS, 2024, 175
  • [6] A hybrid method to improve efficiency of patient specific SRS and SBRT QA using 3D secondary dose verification
    Baltz, Garrett C.
    Manigold, Remy
    Seier, Richard
    Kirsner, Steven M.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (03):
  • [7] Comparison of two commercial 2D-array phantoms for patient-specific QA of stereotactic treatments
    Nevelsky, A.
    Borzov, E.
    Daniel, S.
    Bar-Deroma, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S929 - S930
  • [8] A Novel 3D Printed Patient-Specific Phantom for Spine SBRT Quality Assurance: Comparison of 3D Printing Techniques
    Lee, S.
    Kim, M.
    Lee, M.
    Suh, T.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3631 - 3631
  • [9] Patient-Specific QA of Intensity-Modulated Arc Therapy with 2D Diode Array: Initial Experience
    Tang, G.
    Yi, B.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [10] Enhancement of SRS Patient QA Via 3D Dose Reconstruction From Multiple 2D Planar Measurements
    Fasina, O.
    Duan, J.
    Yin, F.
    Cui, G.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E766 - E766