High-resolution magnetic resonance imaging to characterize the geometry of fatigued porcine bioprosthetic heart valves

被引:0
|
作者
Smith, DB
Sacks, MS
Pattany, PM
Schroeder, R
机构
[1] UNIV MIAMI,DEPT BIOMED ENGN,CORAL GABLES,FL 33124
[2] UNIV MIAMI,DEPT RADIOL,CORAL GABLES,FL 33124
[3] ST JUDE MED INC,ST PAUL,MN
来源
JOURNAL OF HEART VALVE DISEASE | 1997年 / 6卷 / 04期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aims of the study: Porcine bioprosthetic heart valves (PBHV) continue to suffer from limited long-term durability. Failure of PBHV occurs mainly in the cusps and is characterized by mechanical damage, usually in conjunction with calcification, Mechanisms underlying calcification have received considerable attention, yet mechanical damage phenomena remain poorly understood, The structural response of PBHV cusps to in-vivo cyclic loading involves three primary factors: (i) mechanical properties; (ii) fiber architecture; and (iii) 3D geometry, Previous finite element studies have shown cuspal stress distribution to be highly sensitive to subtle changes in geometry, yet to date, cusp geometry has been largely ignored in studies of PBHV durability. Methods: A non-destructive method was developed to quantify PBHV 3D geometry using high-resolution magnetic resonance (MR) imaging, Images were obtained in three orthogonal planes from virgin and accelerated tested (50 x 10(6) and 200 x 10(6) cycles) PBHVs to fully capture 3D cuspal geometry. Surface curvatures were computed using a local biquadric surface patch approach. Results: Results indicated a tendency for cusps to permanently deform with accelerated testing, manifesting primarily as sagging of the cusp. This sagging induced areas of high curvature from the central belly region upwards to the nodulus of Aranti, corresponding to known locations of tissue failure. Conclusions: at is likely that the observed changes in cuspal geometry induce deleterious alterations in the stress distribution, independent of those related to mechanical properties and fiber structure, and contribute tea valve failure. Our results suggest that PBHV designers should attempt to compensate for the deleterious geometric changes that occur post-implantation.
引用
收藏
页码:424 / 432
页数:9
相关论文
共 50 条
  • [21] Clinical applications of high-resolution ocular magnetic resonance imaging
    Tanitame, Keizo
    Sone, Takashi
    Kiuchi, Yoshiaki
    Awai, Kazuo
    JAPANESE JOURNAL OF RADIOLOGY, 2012, 30 (09) : 695 - 705
  • [22] High-resolution magnetic resonance imaging of trabecular bone structure
    Genant, HK
    Majumdar, S
    OSTEOPOROSIS INTERNATIONAL, 1997, 7 (Suppl 3) : 135 - 139
  • [23] High-resolution magnetic resonance imaging for the assessment of hand osteoarthritis
    Tan, AL
    Grainger, AJ
    Tanner, SF
    Shelley, DM
    Pease, C
    Emery, P
    McGonagle, D
    ARTHRITIS AND RHEUMATISM, 2005, 52 (08): : 2355 - 2365
  • [24] High-resolution functional magnetic resonance imaging of the animal brain
    Kim, SG
    Ugurbil, K
    METHODS, 2003, 30 (01) : 28 - 41
  • [25] High-resolution venography of the brain using magnetic resonance imaging
    Jürgen R. Reichenbach
    Marco Essig
    E. Mark Haacke
    Benjamin C. Lee
    Christian Przetak
    Werner A. Kaiser
    Lothar R. Schad
    Magnetic Resonance Materials in Physics, Biology and Medicine, 1998, 6 (1) : 62 - 69
  • [26] The neuroscientific exploitation of high-resolution functional magnetic resonance imaging
    Kriegeskorte, Nikolaus
    Bandettini, Peter
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 6228 - +
  • [27] HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE BRAIN IN CHILDREN
    DUBOWITZ, LMS
    PENNOCK, JM
    JOHNSON, MA
    BYDDER, GM
    CLINICAL RADIOLOGY, 1986, 37 (02) : 113 - 117
  • [28] HIGH-RESOLUTION MAGNETIC-RESONANCE-IMAGING OF THE TEMPORAL BONE
    JAGER, LJ
    MULLERLISSE, U
    REISER, M
    GREVERS, G
    LARYNGO-RHINO-OTOLOGIE, 1994, 73 (07) : 385 - 389
  • [29] High-resolution magnetic resonance imaging of the normal extraocular musculature
    A Ettl
    J Kramer
    A Daxer
    L Koornneef
    Eye, 1997, 11 : 793 - 797
  • [30] High-resolution magnetic resonance imaging for detection of carotid plaques
    Honda, M
    Kitagawa, N
    Tsutsumi, K
    Nagata, I
    Morikawa, M
    Hayashi, T
    NEUROSURGERY, 2006, 58 (02) : 338 - 344