High-resolution magnetic resonance imaging to characterize the geometry of fatigued porcine bioprosthetic heart valves

被引:0
|
作者
Smith, DB
Sacks, MS
Pattany, PM
Schroeder, R
机构
[1] UNIV MIAMI,DEPT BIOMED ENGN,CORAL GABLES,FL 33124
[2] UNIV MIAMI,DEPT RADIOL,CORAL GABLES,FL 33124
[3] ST JUDE MED INC,ST PAUL,MN
来源
JOURNAL OF HEART VALVE DISEASE | 1997年 / 6卷 / 04期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aims of the study: Porcine bioprosthetic heart valves (PBHV) continue to suffer from limited long-term durability. Failure of PBHV occurs mainly in the cusps and is characterized by mechanical damage, usually in conjunction with calcification, Mechanisms underlying calcification have received considerable attention, yet mechanical damage phenomena remain poorly understood, The structural response of PBHV cusps to in-vivo cyclic loading involves three primary factors: (i) mechanical properties; (ii) fiber architecture; and (iii) 3D geometry, Previous finite element studies have shown cuspal stress distribution to be highly sensitive to subtle changes in geometry, yet to date, cusp geometry has been largely ignored in studies of PBHV durability. Methods: A non-destructive method was developed to quantify PBHV 3D geometry using high-resolution magnetic resonance (MR) imaging, Images were obtained in three orthogonal planes from virgin and accelerated tested (50 x 10(6) and 200 x 10(6) cycles) PBHVs to fully capture 3D cuspal geometry. Surface curvatures were computed using a local biquadric surface patch approach. Results: Results indicated a tendency for cusps to permanently deform with accelerated testing, manifesting primarily as sagging of the cusp. This sagging induced areas of high curvature from the central belly region upwards to the nodulus of Aranti, corresponding to known locations of tissue failure. Conclusions: at is likely that the observed changes in cuspal geometry induce deleterious alterations in the stress distribution, independent of those related to mechanical properties and fiber structure, and contribute tea valve failure. Our results suggest that PBHV designers should attempt to compensate for the deleterious geometric changes that occur post-implantation.
引用
收藏
页码:424 / 432
页数:9
相关论文
共 50 条
  • [1] High-resolution magnetic resonance imaging of normal porcine cartilaginous epiphyseal maturation
    Babyn, PS
    Kim, HKW
    Lemaire, C
    Gahunia, HK
    Cross, A
    DeNanassy, J
    Pritzker, KPH
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (01) : 172 - 179
  • [2] High-Resolution Magnetic Resonance Imaging of the Regenerating Adult Zebrafish Heart
    Koth, Jana
    Maguire, Mahon L.
    McClymont, Darryl
    Diffley, Leonie
    Thornton, Victoria L.
    Beech, John
    Patient, Roger K.
    Riley, Paul R.
    Schneider, Juergen E.
    SCIENTIFIC REPORTS, 2017, 7
  • [3] High-Resolution Magnetic Resonance Imaging of the Regenerating Adult Zebrafish Heart
    Jana Koth
    Mahon L. Maguire
    Darryl McClymont
    Leonie Diffley
    Victoria L. Thornton
    John Beech
    Roger K. Patient
    Paul R. Riley
    Jürgen E. Schneider
    Scientific Reports, 7
  • [4] High-resolution magnetic resonance imaging and diffusion tensor imaging of the porcine temporomandibular joint disc
    Benavides, E.
    Bilgen, M.
    Al-Hafez, B.
    Alrefae, T.
    Wang, Y.
    Spencer, P.
    DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (03) : 148 - 155
  • [5] High-resolution magnetic resonance instant imaging
    Emid, S.
    PHYSICA B-CONDENSED MATTER, 2007, 398 (01) : 38 - 39
  • [6] Tractography of Porcine Meniscus Microstructure Using High-Resolution Diffusion Magnetic Resonance Imaging
    Shen, Jikai
    Zhao, Qi
    Qi, Yi
    Cofer, Gary
    Johnson, G. Allan
    Wang, Nian
    FRONTIERS IN ENDOCRINOLOGY, 2022, 13
  • [7] Cardiac magnetic resonance imaging in systemic sclerosis: Heart involvement in high-resolution
    Fairley, Jessica L.
    O'Rourke, Rachael
    Puranik, Rajesh
    Nikpour, Mandana
    RHEUMATOLOGY AND IMMUNOLOGY RESEARCH, 2024, 5 (02): : 83 - 92
  • [8] High-resolution assessment of velocity fields and shear stresses distal to prosthetic heart valves using high-field magnetic resonance imaging
    Ringgaard, S
    Botnar, RM
    Djurhuus, C
    Stodkilde-Jorgensen, H
    Hasenkam, JM
    Boesiger, P
    Pedersen, EM
    JOURNAL OF HEART VALVE DISEASE, 1999, 8 (01): : 96 - 103
  • [9] High-resolution magnetic resonance imaging of recurrent pneumoparotitis
    Sittel, C
    Jungehülsing, M
    Fischbach, R
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (08): : 816 - 818
  • [10] High-resolution Magnetic Resonance Imaging of Moyamoya Disease
    Yu Le-Bao
    Zhang Qian
    Shi Zhi-Yong
    Wang Ming-Qiu
    Zhang Dong
    中华医学杂志(英文版), 2015, (23) : 3231 - 3237