DEVELOPMENT OF A VALIDATED METHOD FOR SIMULTANEOUS QUANTIFICATION OF CLARITHROMYCIN AND LEVOFLOXACIN BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTOR

被引:2
|
作者
Ijaz, Qazi Amir [1 ]
Abbas, Nasir [1 ]
Latif, Sumera [2 ]
Hussain, Amjad [1 ]
Arshad, Muhammad Sohail [3 ]
Ali, Ejaz [1 ]
Rashid, Memoona [1 ]
Sohail, Kashif [4 ]
Riaz, Sohail [4 ]
Bukhari, Nadeem Irfan [1 ]
机构
[1] Univ Punjab, Univ Coll Pharm, Lahore, Pakistan
[2] Lahore Coll Women Univ, Fac Pharmaceut & Allied Hlth Sci, Inst Pharm, Lahore, Pakistan
[3] Bahauddin Zakariya Univ, Dept Pharmaceut, Multan, Pakistan
[4] Mirpur Univ Sci & Technol, Akron Coll Pharm, Mirpur, AJ&K, Pakistan
来源
ACTA POLONIAE PHARMACEUTICA | 2020年 / 77卷 / 06期
关键词
clarithromycin; levofloxacin; high-performance liquid chromatography; diode array detector; validation; simultaneous quantification; HPLC METHOD; IN-VITRO; RP-HPLC; PHARMACOKINETICS; COMBINATIONS; IMPURITIES; BULK;
D O I
10.32383/appdr/131197
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This study aims at the development of a validated reverse phase-high performance liquid chromatography (RP-HPLC) method for the simultaneous quantification of levofloxacin (LVX) and clarithromycin (CAM). Eclipse X DB C18 column (5 mu m, 4.6 x250 mm) was used as a stationary phase, and monobasic potassium phosphate (KH2PO4) buffer (0.035 M): acetonitrile (75 : 25) was used as an isocratic mobile phase. The pH of the mobile phase was adjusted to 4.5 with the help of diluted orthophosphoric acid. The diode array detector (DAD) was operated at 205 nm and 294 nm for the detection of CAM and LVX, respectively. Limit of detection (LOD) values for CAM and LVX were 1.22 mu g/mL and 0.79 mu g/mL, respectively. Limit of quantification(LOQ) values for CAM and LVX were 4.08 mu g/mL and 2.64 mu g/mL, respectively. The method was precise as% relative standard deviation (% RSD) values were less than 2% for all types of precision. This method was successfully applied to determine the percentage contents of both drugs in the pharmaceutical preparation.
引用
下载
收藏
页码:841 / 847
页数:7
相关论文
共 50 条
  • [41] The simultaneous determination of coumarins in Angelica gigas root by high performance liquid chromatography-diode array detector coupled with electrospray ionization/mass spectrometry
    Ahn, Mi-Jeong
    Lee, Mi Kyeong
    Kim, Young Choong
    Sung, Sang Hyun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (02) : 258 - 266
  • [42] Gas chromatography-mass spectrometry and high-performance liquid chromatography-diode array detection for dating of paper ink
    Diaz-Santana, Oscar
    Vega-Moreno, Daura
    Conde-Hardisson, Francisco
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1515 : 187 - 195
  • [43] Simultaneous Determination of 11 Components in Yinzhihuang Preparations and Their Constituent Herbs by High-Performance Liquid Chromatography with Diode Array Detector
    Du, Yan
    Han, Jie
    Sun, Shi-an
    Li, Zheng
    Yang, Fang-xiu
    Dong, Lu-lu
    Yang, Dong-zhi
    Tang, Dao-quan
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2016, 54 (04) : 625 - 632
  • [44] Simultaneous determination of 22 sunscreen agents in cosmetics by ultra -high-performance liquid chromatography using diode array detector
    Zhang Keming
    Deng Ming
    Su Yuanyuan
    Xie Dong
    Xu Youcheng
    Liu Xianghong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2021, 39 (04) : 415 - 423
  • [45] Simultaneous determination of synthetic dyes in foodstuffs and beverages by high-performance liquid chromatography coupled with diode-array detector
    Bonan, Stefania
    Fedrizzi, Giorgio
    Menotta, Simonetta
    Elisabetta, Caprai
    DYES AND PIGMENTS, 2013, 99 (01) : 36 - 40
  • [46] Simultaneous determination of 9 preservatives in processed foods using high-performance liquid chromatography with photo diode array detector
    Lee, Do-Yeon
    Kim, Min-Hee
    Ahn, Jang-Hyuk
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2020, 33 (06): : 233 - 239
  • [47] Simultaneous quantification of coumarins, flavonoids and limonoids in Fructus Citri Sarcodactylis by high performance liquid chromatography coupled with diode array detector
    Chu, Jun
    Li, Song-Lin
    Yin, Zhi-Qi
    Ye, Wen-Cai
    Zhang, Qing-Wen
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 66 : 170 - 175
  • [48] Simultaneous qualitation and quantification of four phytoecdysones in Radix Achyranthis Bidentatae by high-performance liquid chromatography with diode array detection
    Li, Juan
    Li, Hui-Jun
    Li, Ping
    Qi, Hui
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (08) : 823 - 828
  • [49] Simultaneous quantification and identification of Amaryllidaceae alkaloids in Narcissus tazetta by ultra performance liquid chromatography-diode array detector-electrospray ionisation tandem mass spectrometry
    Katoch, Deepali
    Sharma, Upendra
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 175
  • [50] Development of a high-performance liquid chromatography method for simultaneous quantification of sixteen polyphenols and application to tomato
    Xiao, Xuemei
    Liu, Fanhong
    Sun, Mingming
    Tang, Zhongqi
    Wu, Yue
    Lyu, Jian
    Khan, Khuram Shehzad
    Yu, Jihua
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1733