DEVELOPMENT OF A VALIDATED METHOD FOR SIMULTANEOUS QUANTIFICATION OF CLARITHROMYCIN AND LEVOFLOXACIN BY HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY-DIODE ARRAY DETECTOR

被引:2
|
作者
Ijaz, Qazi Amir [1 ]
Abbas, Nasir [1 ]
Latif, Sumera [2 ]
Hussain, Amjad [1 ]
Arshad, Muhammad Sohail [3 ]
Ali, Ejaz [1 ]
Rashid, Memoona [1 ]
Sohail, Kashif [4 ]
Riaz, Sohail [4 ]
Bukhari, Nadeem Irfan [1 ]
机构
[1] Univ Punjab, Univ Coll Pharm, Lahore, Pakistan
[2] Lahore Coll Women Univ, Fac Pharmaceut & Allied Hlth Sci, Inst Pharm, Lahore, Pakistan
[3] Bahauddin Zakariya Univ, Dept Pharmaceut, Multan, Pakistan
[4] Mirpur Univ Sci & Technol, Akron Coll Pharm, Mirpur, AJ&K, Pakistan
来源
ACTA POLONIAE PHARMACEUTICA | 2020年 / 77卷 / 06期
关键词
clarithromycin; levofloxacin; high-performance liquid chromatography; diode array detector; validation; simultaneous quantification; HPLC METHOD; IN-VITRO; RP-HPLC; PHARMACOKINETICS; COMBINATIONS; IMPURITIES; BULK;
D O I
10.32383/appdr/131197
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This study aims at the development of a validated reverse phase-high performance liquid chromatography (RP-HPLC) method for the simultaneous quantification of levofloxacin (LVX) and clarithromycin (CAM). Eclipse X DB C18 column (5 mu m, 4.6 x250 mm) was used as a stationary phase, and monobasic potassium phosphate (KH2PO4) buffer (0.035 M): acetonitrile (75 : 25) was used as an isocratic mobile phase. The pH of the mobile phase was adjusted to 4.5 with the help of diluted orthophosphoric acid. The diode array detector (DAD) was operated at 205 nm and 294 nm for the detection of CAM and LVX, respectively. Limit of detection (LOD) values for CAM and LVX were 1.22 mu g/mL and 0.79 mu g/mL, respectively. Limit of quantification(LOQ) values for CAM and LVX were 4.08 mu g/mL and 2.64 mu g/mL, respectively. The method was precise as% relative standard deviation (% RSD) values were less than 2% for all types of precision. This method was successfully applied to determine the percentage contents of both drugs in the pharmaceutical preparation.
引用
下载
收藏
页码:841 / 847
页数:7
相关论文
共 50 条
  • [21] Chemotaxonomic Monitoring of Genetically Authenticated Amomi Fructus Using High-Performance Liquid Chromatography-Diode Array Detector with Chemometric Analysis
    Doh, Eui-Jeong
    Lee, Guemsan
    Jung, Hyun-Jong
    Kwon, Kang-Beom
    Kim, Jung-Hoon
    MOLECULES, 2020, 25 (19):
  • [22] A validated high-performance liquid chromatography method with diode array detection for simultaneous determination of nine flavonoids in Senecio cannabifolius Less.
    Niu, Tian-Zeng
    Zhang, Yu-Wei
    Bao, Yong-Li
    Wu, Yin
    Yu, Chun-Lei
    Sun, Lu-Guo
    Yi, Jing-Wen
    Huang, Yan-Xin
    Li, Yu-Xin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 76 : 44 - 48
  • [23] Development and validation of a High Performance Liquid Chromatography-Diode Array Detection method for the determination of aging markers in tequila
    Celia Munoz-Munoz, Ana
    Charles Grenier, Adam
    Gutierrez-Pulido, Humberto
    Cervantes-Martinez, Jesus
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1213 (02) : 218 - 223
  • [24] Imatinib Quantification in Human Serum for Clinical Purposes using High-performance Liquid Chromatography with a Diode Array Detector
    Dziadosz, Marek
    Bartels, Heidemarie
    ACTA CHIMICA SLOVENICA, 2011, 58 (02) : 347 - 350
  • [25] Study of an accelerated solvent extraction procedure for the determination of acaricide residues in honey by high-performance liquid chromatography-diode array detector
    Korta, E
    Bakkali, A
    Berrueta, LA
    Gallo, B
    Vicente, F
    JOURNAL OF FOOD PROTECTION, 2002, 65 (01) : 161 - 166
  • [26] Determination of chloroacetanilide herbicide metabolites in water using high-performance liquid chromatography-diode array detection and high-performance liquid chromatography/mass spectrometry
    Hostetler, KA
    Thurman, EM
    SCIENCE OF THE TOTAL ENVIRONMENT, 2000, 248 (2-3) : 147 - 155
  • [27] A non-extraction method for the determination of prothionamide in human plasma samples by high performance liquid chromatography-diode array detector
    Ionescu, M
    David, V
    Medvedovici, A
    REVUE ROUMAINE DE CHIMIE, 2002, 47 (8-9) : 855 - 860
  • [28] High-performance liquid chromatography-diode array detection assay for the detection and quantification of the Beauveria metabolite oosporein from potato tubers
    Seger, C
    Längle, T
    Pernfuss, B
    Stuppner, H
    Strasser, H
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1092 (02) : 254 - 257
  • [29] Simultaneous determination of furosemide and carbamazepine in biological matrices by solvent bar microextraction combined with high-performance liquid chromatography-diode array detector and central composite design
    Al-Hashimi, Nabil N.
    Al-Degs, Yahya S.
    Jaafreh, Sawsan
    Al-Khatib, Hatim S.
    El-Sheikh, Amjad H.
    Abdelghani, Jafar, I
    Jaber, Mai R.
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (11)
  • [30] Simultaneous Analysis of Three Bioactive Compounds in Artemisia annua Hairy Root Cultures by Reversed-phase High-performance Liquid Chromatography-Diode Array Detector
    Zhai, Dan-Dan
    Zhong, Jian-Jiang
    PHYTOCHEMICAL ANALYSIS, 2010, 21 (06) : 524 - 530