The effect of flow pulsations on coriolis mass flow meters

被引:41
|
作者
Cheesewright, R [1 ]
Clark, C [1 ]
机构
[1] Brunel Univ, Dept Mfg & Engn Syst, Uxbridge UB8 3PH, Middx, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1006/jfls.1998.0176
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
It has been reported that the accuracy of Coriolis mass flow meters can be adversely affected by the presence of pulsations (at particular frequencies) in the flow. A full analysis of the transient performance of a commercial Coriolis meter is only possible using finite element techniques. However, this is a transient, nonlinear problem in which the space and time variables are not (strictly) separable and the finite element techniques for tackling such problems make it desirable to have an analytical solution for a simplified meter, against which the finite element solution can be compared. This paper reports such a solution. The solution will also provide guidance for experiments. Existing analytical solutions for the performance of Coriolis meters in steady flow (a complex eigenvalue problem) are not easily extended to the transient flow case. The paper thus begins with the presentation of an alternative solution for steady how through a simple, straight tube, Coriolis meter and it is notable that this solution gives a simple analytical expression for the experimentally observed small change in the resonant frequency of the meter, with flow rate, as well as an analytical expression for the meter sensitivity. The analysis is extended to the transient case, using classical, forced vibration, modal decomposition techniques. The solution shows that, unlike the steady flow case where the detector signals contain components at the drive frequency and the second mode frequency (Coriolis frequency), for pulsatile flow the detector signals will in general contain components involving at least four frequencies. It is demonstrated that the meter error depends on the algorithm used to estimate the phase difference from the detector signals. The particular flow pulsation frequencies which could possibly lead to large meter errors are identified. (C) 1998 Academic Press.
引用
收藏
页码:1025 / 1039
页数:15
相关论文
共 50 条
  • [31] μ-Coriolis Mass Flow Sensor with Resistive Readout
    Schut, Thomas
    Wiegerink, Remco
    Lotters, Joost
    [J]. MICROMACHINES, 2020, 11 (02)
  • [32] Optimization of a micro Coriolis mass flow sensor
    Groenesteijn, J.
    Lammerink, T. S. J.
    Wiegerink, R. J.
    Haneveld, J.
    Lotters, J. C.
    [J]. EUROSENSORS XXV, 2011, 25
  • [33] Measurement corrections for temperature effects in Coriolis mass flow meters for cryogenic, liquid hydrogen (LH 2 ) applications
    Kutin, Joze
    Bobovnik, Gregor
    Mole, Nikolaj
    Schakel, Menne D.
    Buker, Oliver
    [J]. MEASUREMENT, 2024, 237
  • [34] The resonance of Coriolis Mass Flowmeters in a pulsating flow
    Mori, Y
    Shibata, M
    [J]. SICE 2003 ANNUAL CONFERENCE, VOLS 1-3, 2003, : 10 - 14
  • [35] CORIOLIS MASS-FLOW ON THE HIGH ROAD
    TINHAM, B
    [J]. CONTROL AND INSTRUMENTATION, 1993, 25 (02): : 29 - &
  • [36] Coriolis: The Direct Approach to Mass Flow Measurement
    O'Banion, Tom
    [J]. CHEMICAL ENGINEERING PROGRESS, 2013, 109 (03) : 41 - 46
  • [37] Coriolis mass flow measurement at cryogenic temperatures
    Wang, Tao
    Hussain, Yousif
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2009, 20 (03) : 110 - 115
  • [38] Coriolis Mass Flow Metering for Wet Gas
    Lansangan, Robbie
    Skinner, Jacob
    Reese, Michael
    Del Toro, Arnold
    Tombs, Michael
    Duta, Mihaela
    Zhou, Feibiao
    Henry, Manus
    [J]. MEASUREMENT & CONTROL, 2008, 41 (07): : 213 - 216
  • [40] A coriolis mass flow sensor structure in silicon
    Enoksson, P
    Stemme, G
    Stemme, E
    [J]. NINTH ANNUAL INTERNATIONAL WORKSHOP ON MICRO ELECTRO MECHANICAL SYSTEMS, IEEE PROCEEDINGS: AN INVESTIGATION OF MICRO STRUCTURES, SENSORS, ACTUATORS, MACHINES AND SYSTEMS, 1996, : 156 - 161