Coriolis Mass Flow Metering for Wet Gas

被引:5
|
作者
Lansangan, Robbie
Skinner, Jacob
Reese, Michael
Del Toro, Arnold
Tombs, Michael [1 ]
Duta, Mihaela [1 ]
Zhou, Feibiao [1 ]
Henry, Manus [1 ]
机构
[1] Univ Oxford, Oxford OX1 2JD, England
来源
MEASUREMENT & CONTROL | 2008年 / 41卷 / 07期
关键词
Gas industry - Natural gas fields - Air - Mass transfer - Flow measurement - Flowmeters - Two phase flow - Void fraction;
D O I
10.1177/002029400804100703
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Most two-phase applications for Coriolis moss flow metering are for low Gas Void Fraction (GVF) conditions, i.e. where the process fluid is essentially liquid with relatively low levels of entrained air or gas. There are particular challenges associated with metering wet gas, where the GVF exceeds 95%. Established wet gas metering techniques are typically based on a differential pressure-type device (for example on orifice plate or V-cone). It is well-known that such devices over-read compared to a dry gas calibration; equations to correct the reading are available if the degree of gas "wetness" is known. For Coriolis moss flow metering of wet gas, two approaches are described. The natural extension of the low GVF techniques is to map the observed mass flow and density readings onto estimates of the flow rates of the gas and liquid components. The alternative is to use the Coriolis meter to estimate the degree of gas "wetness" (e.g. the Lockhart-Mortinelli number) and to apply a conventional correlation (e.g. Murdock or Chisholm) to a differential pressure flow reading. A prototype Coriolis-based wet gas meter is described, together with results from laboratory trials at CEESI in Colorado, and from extended held trials at BP's Wamsutter gas held in Wyoming.
引用
收藏
页码:213 / 216
页数:4
相关论文
共 50 条
  • [1] Using Coriolis Mass Flowmeter for Wet Gas Metering
    Geng, Yanfeng
    Yeung, Hoi
    Cao, Yi
    Xing, Lanchang
    Zhu, Hao
    Drahm, Wolfgang
    [J]. MEASUREMENT & CONTROL, 2010, 43 (06): : 183 - 185
  • [2] Oil and gas applications for digital coriolis mass flow metering - Introduction
    FInstMC
    [J]. Meas Control, 2008, 7 (203-204):
  • [3] Oil And Gas Applications For Digital Coriolis Mass Flow Metering - Introduction
    Henry, Manus
    [J]. MEASUREMENT & CONTROL, 2008, 41 (07): : 203 - 204
  • [4] Coriolis mass flow metering with multiphase media
    Rieder, A
    Matt, C
    [J]. SENSORS AND MEASURING SYSTEMS 2004, 2004, 1829 : 381 - 382
  • [5] CORIOLIS-EFFECT IN MASS-FLOW METERING
    RASZILLIER, H
    DURST, F
    [J]. ARCHIVE OF APPLIED MECHANICS, 1991, 61 (03) : 192 - 214
  • [6] Coriolis mass flow metering for three-phase flow: A case study
    Henry, Manus
    Tombs, Michael
    Zamora, Mayela
    Zhou, Feibiao
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 30 : 112 - 122
  • [7] An FPGA implementation of a digital Coriolis mass flow metering drive system
    Zamora, Mayela
    Henry, Manus P.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (07) : 2820 - 2831
  • [8] Fast Coriolis mass flow metering for monitoring diesel fuel injection
    Leach, Felix
    Karout, Salah
    Zhou, Feibiao
    Tombs, Michael
    Davy, Martin
    Henry, Manus
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 58 : 1 - 5
  • [9] Coriolis gas metering moving into mainstream
    不详
    [J]. CONTROL ENGINEERING, 1998, 45 (14) : 8 - 8
  • [10] Complex signal processing for Coriolis mass flow metering in two-phase flow
    Li, Ming
    Henry, Manus