Normally-closed shape memory microvalve

被引:0
|
作者
Kohl, A [1 ]
Göbes, J [1 ]
Krevet, B [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Mikrostrukturtech, D-76021 Karlsruhe, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new type of normally-closed gas microvalve is presented. The valve makes use of two micromachined SMA thin sheet devices, an active SMA device displaying the one-way shape memory effect and a passive superelastic SMA device, which maintains a normally-closed position. The outer diameter and height of the valve, are 6 mm. Gas flow experiments in stationary equilibrium reveal a maximum flow of 470 standard ccm (sccm) at a pressure difference of 8000 hPa and a power consumption of 260 mW. The dynamics of heat transfer to and from the active microdevice is investigated by infrared microscopy and coupled FEM simulations. At 300 mW heating power, the heating time is about 1.2 s. Typical cooling times vary between 1.8 and 5 s depending on the gas flow.
引用
收藏
页码:71 / 77
页数:7
相关论文
共 50 条
  • [41] The divergent environmental characteristics of permanently-open, seasonally-open and normally-closed estuaries of south-western Australia
    Chuwen, Benjamin M.
    Hoeksema, Steeg D.
    Potter, Ian C.
    ESTUARINE COASTAL AND SHELF SCIENCE, 2009, 85 (01) : 12 - 21
  • [42] Factors influencing the characteristics of the fish faunas in offshore, deeper waters of permanently-open, seasonally-open and normally-closed estuaries
    Chuwen, Benjamin M.
    Hoeksema, Steeg D.
    Potter, Ian C.
    ESTUARINE COASTAL AND SHELF SCIENCE, 2009, 81 (03) : 279 - 295
  • [43] A low-power high-flow shape memory alloy wire gas microvalve
    Gradin, Henrik
    Clausi, Donato
    Braun, Stefan
    Stemme, Goran
    Peirs, Jan
    van der Wijngaart, Wouter
    Reynaerts, Dominiek
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2012, 22 (07)
  • [44] Closed loop control for shape memory alloy actuators
    Auerswald, Christian
    Senf, Bjoern
    Mehner, Jan
    Drossel, Welf-Guntram
    2014 11TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2014,
  • [45] NORMALLY CLOSED SATURATED FORMATIONS
    HALE, MP
    PROCEEDINGS OF THE AMERICAN MATHEMATICAL SOCIETY, 1972, 33 (02) : 337 - &
  • [46] Piezoelectric Normally Open Microvalve with Multiple Valve Seat Trenches for Medical Applications
    Durasiewicz, Claudia Patricia
    Guentner, Sophia Thekla
    Maier, Philipp Klaus
    Hoelzl, Wolfgang
    Schrag, Gabriele
    APPLIED SCIENCES-BASEL, 2021, 11 (19):
  • [47] Innovative multiphysics approach for designing high-performance thermo-responsive shape memory polymer microvalve
    Enferadi, Alireza
    Baniassadi, Majid
    Baghani, Mostafa
    EUROPEAN JOURNAL OF MECHANICS A-SOLIDS, 2024, 103
  • [48] Highly integrable and normally open microvalve for industrial thermoplastic-based lab on PCB
    Perdigones, Francisco
    Manuel Quero, Jose
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 300
  • [49] CLOSED TWO-WAY SHAPE MEMORY EFFECT IN UNIDIRECTIONAL COMPOSITE WITH SHAPE MEMORY ALLOY FIBERS AND ELASTIC MATRIX
    Movchan, A. A.
    Chernov, M., I
    COMPOSITES-MECHANICS COMPUTATIONS APPLICATIONS, 2019, 10 (02): : 135 - 156
  • [50] Fully Closed-Loop Recyclable Thermosetting Shape Memory Polyimide
    Yang, Zenghui
    Zhang, Yaoming
    Li, Song
    Zhang, Xinrui
    Wang, Tingmei
    Wang, Qihua
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2020, 8 (51) : 18869 - 18878