Normally-closed shape memory microvalve

被引:0
|
作者
Kohl, A [1 ]
Göbes, J [1 ]
Krevet, B [1 ]
机构
[1] Forschungszentrum Karlsruhe, Inst Mikrostrukturtech, D-76021 Karlsruhe, Germany
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new type of normally-closed gas microvalve is presented. The valve makes use of two micromachined SMA thin sheet devices, an active SMA device displaying the one-way shape memory effect and a passive superelastic SMA device, which maintains a normally-closed position. The outer diameter and height of the valve, are 6 mm. Gas flow experiments in stationary equilibrium reveal a maximum flow of 470 standard ccm (sccm) at a pressure difference of 8000 hPa and a power consumption of 260 mW. The dynamics of heat transfer to and from the active microdevice is investigated by infrared microscopy and coupled FEM simulations. At 300 mW heating power, the heating time is about 1.2 s. Typical cooling times vary between 1.8 and 5 s depending on the gas flow.
引用
收藏
页码:71 / 77
页数:7
相关论文
共 50 条
  • [21] Normally-closed peristaltic micropump with re-usable actuator and disposable fluidic chip
    Trenkle, F.
    Haeberle, S.
    Zengerle, R.
    PROCEEDINGS OF THE EUROSENSORS XXIII CONFERENCE, 2009, 1 (01): : 1515 - +
  • [22] Normally-closed peristaltic micropump with re-usable actuator and disposable fluidic chip
    Trenkle, F.
    Haeberle, S.
    Zengerle, R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 154 (02): : 137 - 141
  • [23] A shape memory alloy microvalve with flow sensing
    Piccini, ME
    Towe, BC
    SENSORS AND ACTUATORS A-PHYSICAL, 2006, 128 (02) : 344 - 349
  • [24] PMP-NC2 - A Bi-Directional, Normally-Closed and Backpressure Independent Micropump
    Trenkle, F.
    Mayer, M.
    Haeberle, S.
    Messner, S.
    Zengerle, R.
    ACTUATOR 10, CONFERENCE PROCEEDINGS, 2010, : 234 - +
  • [25] Normally closed electrostatic microvalve with pressure balance mechanism for portable fuel cell application
    Yoshida, Kazushi
    Tanaka, Shuji
    Hagihara, Yosuke
    Tomonari, Shigeaki
    Esashi, Masayoshi
    SENSORS AND ACTUATORS A-PHYSICAL, 2010, 157 (02) : 290 - 298
  • [26] Fabrication of whole-thermoplastic normally closed microvalve, micro check valve, and micropump
    Pourmand, Adel
    Shaegh, Seyed Ali Mousavi
    Ghavifekr, Habib Badri
    Aghdam, Esmaiel Najafi
    Dokmeci, Mehmet Remzi
    Khademhosseini, Ali
    Zhang, Yu Shrike
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 262 : 625 - 636
  • [27] Normally-closed electrostatic micro valve with pressure balance mechanism for portable fuel cell application
    Yoshida, K
    Hagihara, Y
    Tanaka, S
    Esashi, M
    MEMS 2006: 19TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2006, : 722 - 725
  • [28] Uniform cell seeding and generation of overlapping gradient profiles in a multiplexed microchamber device with normally-closed valves
    Mosadegh, Bobak
    Agarwal, Mayank
    Tavana, Hossein
    Bersano-Begey, Tommaso
    Torisawa, Yu-suke
    Morell, Maria
    Wyatt, Matthew J.
    O'Shea, K. Sue
    Barald, Kate F.
    Takayama, Shuichi
    LAB ON A CHIP, 2010, 10 (21) : 2959 - 2964
  • [29] A Bistable Shape Memory Alloy Microvalve With Magnetostatic Latches
    Barth, Johannes
    Megnin, Christof
    Kohl, Manfred
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2012, 21 (01) : 76 - 84
  • [30] Analysis of Membrane Behavior of a Normally Closed Microvalve Using a Fluid-Structure Interaction Model
    Natarajan, Guru Prasath
    Kim, Sung-Jin
    Kim, Chang-Wan
    MICROMACHINES, 2017, 8 (12)